Preferred Language
Articles
/
jkmc-395
Correlation between magnetic resonance imaging and intra-operative findings in disc herniation at lumbo-sacral region
...Show More Authors

Background: Prolapsed intervertebral disc is an important and common cause of low backache. MRI has now become universally accepted investigation for prolapsed intervertebral disc. We, however, regularly come across situations, when MRI shows diffuse disc bulges, even at multiple levels, which cannot be correlated clinically and when such cases are operated, no significant disc prolapse is found resulting in negative exploration.Objective: To evaluate the role of M.R.I. finding not only for diagnosis of disc herniation at lumbar region but also for localization the level of herniationMethods: A prospective study on seventy five symptomatic low backache and MRI confirmed prolapsed intervertebral disc patients at lumbo-sacral region were operated on, all of the cases required excision of disc through posterior approach in knee elbow position. The time between MRI taken and surgery was two weeks, from which the data were taken in a questioner forma which include name , age ,gender , occupation , chief complaint , duration, MRI findings and intra operative finding , from June 2011 to October 2013 at Al- Kindy teaching hospital .Results: In our study 75 patients were diagnosed by clinical examination and MRI finding to have disc herniation at lumbar region . The female more than male( 36 females , 12 males) and the ratio was 5-1, the accuracy of MRI against intra operative finding in deciding the provisional diagnosis as disc herniation was 68% .The commonest site was L4-5 disc herniation 43 patients (57.3 % ) , and L5-S1 prolapse is the next common disc herniation level 27 patient (36 % ) , L3-L4 disc herniation was two cases (2.7 %) and L4-L5 ,L5-S1 disc herniation was 3 cases (4% ).Conclusion: The most common level was L4-5 followed by L5S1.The MRI is more accurate in diagnosis of the lumbo-sacral disc herniation and its level in single one is more than multiple levels.Keywords: Disc herniation, MRI, Surgery, posterior approachAl

View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Jan 01 2018
Journal Name
International Journal Of Surgery Open
Does preoperative magnetic resonant cholangiopancreatography (MRCP), improve the safety of laparoscopic cholecystectomy?
...Show More Authors

Publication Date
Wed May 17 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Investigation of the Projector Properties of the Magnetic lenses Using Analytical Function
...Show More Authors

 A computational investigation has been carried out to describe synthesis optimization procedure of magnetic lenses. The research is concentrated on the determination of the inverse design of the symmetrical double polepiece magnetic lenses whose magnetic field distribution is already defined. Magnetic lenses field model well known in electron optics have been used as the axial magnetic field distribution. This field has been studied when the halfwidth is variable and the maximum magnetic flux density is kept constant. The importance of this research lies in the possibility of using the present synthesis optimization procedure for finding the polepieces design of symmetrical double polepiece magnetic lenses which have the best proje

... Show More
View Publication Preview PDF
Publication Date
Mon Jan 01 2018
Journal Name
International Journal Of Surgery Open
Does preoperative magnetic resonant cholangiopancreatography (MRCP), improve the safety of laparoscopic cholecystectomy?
...Show More Authors
<bold>ABSTRACT</bold> <sec> <title>Background:

Magnetic resonance cholangiopancreatography (MRCP) is a non-invasive imaging test with excellent overall sensitivity and specificity for demonstrating the level and the presence of a biliary obstruction. MRCP has emerged as an accurate, diagnostic modality for investigating the biliary and pancreatic duct. In some cases, it has been recommended that preoperative MRCP is a good choice for the detection of CBD stones.

Aim:

The aim of the s

... Show More
View Publication
Scopus (3)
Crossref (3)
Scopus Crossref
Publication Date
Tue Jun 30 2015
Journal Name
Al-khwarizmi Engineering Journal
The Influence of the Magnetic Abrasive Finishing System for Cylindrical Surfaces on the Surface Roughness and MRR
...Show More Authors

Abstract

Magnetic abrasive finishing (MAF) is one of the advanced finishing processes, which produces a high level of surface quality and is primarily controlled by a magnetic field. This paper study the effect of the magnetic abrasive finishing system on the material removal rate (MRR) and surface roughness (Ra) in terms of magnetic abrasive finishing system for eight of input parameters, and three levels according to Taguchi array (L27) and using the regression model to analysis the output (results). These parameters are the (Poles geometry angle, Gap between the two magnetic poles, Grain size powder, Doze of the ferromagnetic abrasive powder, DC current, Workpiece velocity, Magnetic poles velocity, and Finishi

... Show More
View Publication Preview PDF
Publication Date
Fri Dec 29 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Effect of Different Magnetic Fields on The Relative Efficiency and The Energy Resolution of Nai(TI) Detectors
...Show More Authors

The effect of different magnetic Jiel ds on the Nal(Tl) scintillation detector of (3"x3") and (1.5"x1.5")   sizes was studies, using the radioactive source Cs-137.

Two type:; of coils (A,B)  were used to produce the magnetic fields. The coil "A" is cylindrical of "9cm" diameter and "9cm" length , and of

2500 turns.

The measurements were taken in two positions ;the first when the crystal inside the coil ,and the second, the PMT inside the coil . The range of the magnetic field was (0.35,0.61,0.84,1.1 1,1.37,1.62,1.87 and

2.12) mT.

The coil "D" consists of two circular and parallel coils of "12 em" distance between them and of "18.5 em" diameter of each other and of "125" turns. rive &

... Show More
View Publication Preview PDF
Publication Date
Tue Aug 23 2022
Journal Name
International Journal Of Health Sciences
Association between periostin and bone minerals in osteoporosis and osteopenia Iraqi patients
...Show More Authors

Background: osteoporosis is characterized by a reduction in bone mineral density, skeletal microstructure breakdown, increased bone fragility, and fracture susceptibility. Osteopenia is the preceding step to osteoporosis because it causes a decrease in bone mass, osteoporosis reduces a person's quality of life. Periostin (encoded by Postn), its name is derived from the fact that it was first detected in periosteal osteocytes and osteoblasts. Periostin deficiency has been linked to osteoporosis and weak bones. Study objectives: The purpose of this study was to determine periostin levels in serum of Iraqi patients with osteoporosis and osteopenia, and it is also possible to consider periostin as a diagnostic factor to follow the progression o

... Show More
Publication Date
Thu Aug 20 2020
Journal Name
Talent Development & Excellence
Turn-Taking in Conversation between a Chef and Boss and among Chefs
...Show More Authors

DBN Rashid, Talent Development & Excellence, 2020

View Publication
Publication Date
Mon May 22 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Some Robust Tests for the Correlation Coefficient: A Comparative Study
...Show More Authors

This paper is Interested with studying the performance of statistic test the hypothesis of independence of the two variables (the hypothesis that there is no correlation between the variables under study) in the case of data to meet the requirement of normal distribution in the case away from the distribution due to the presence of outliers (contaminated values) and compared with the performance of some of the other methods proposed and modified

View Publication Preview PDF
Publication Date
Tue Jan 01 2019
Journal Name
Plant Archives,
Phenotypic, genotypic correlation and path coefficient for severaltraits of maize under watered and water stress (agronomic traits)
...Show More Authors

Scopus (2)
Scopus
Publication Date
Fri Jun 13 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Computed tomographic localization of infraorbital foramen position and correlation with the age and gender of Iraqi subjects
...Show More Authors

Background: The Infraorbital foramen is an anatomical structure with an important location in the maxilla, position of foramen in maxillofacial area is necessary in clinical situation requiring regional nerve blocks that are performed in children undergoing facial surgeries to avoid injury to corresponding nerve. The aim of study was to determine the position of the Infraorbital foramen and to correlate Infraorbital foramen position with age and gender using computed tomography. Subjects, Materials, and Methods: The sample consist of prospective study for 50 Iraqi subjects (21 male and 29 female) with age ranged from (5-17) years. The examination was performed on Multi – Slice Spiral Tomography scanner in Al-Karakh General Hospital. Using

... Show More
View Publication Preview PDF