Background: Since its introduction to musculoskeletal imaging in the early 1980, magnetic resonance imaging (MRI) has revolutionized diagnostic imaging of the knee. It is therefore become the examination of choice in the evaluation of internal joint structures of the knee like menisci, cruciate ligaments, and articular cartilage.Objectives: to describe the MRI finding in various knee injuries.Patients and methods: A cross sectional study was done on 130 patients with history of knee injury in MRI unit at institute of radiology and al-Shaheed Ghazi Al-Hariri Hospital in medical city complex - Baghdad, from October 2011 to February 2013 includes 103 men, 27 women; the mean age was 33.86 years. MR imaging studies of the knee performed using a 1.5 T MR system. The sequences included coronal and sagittal PD, sagittal T2 FSE, fat suppressed T2 FSE, STIR axial and coronal. Knee MR studies were obtained to evaluate ligament, menisci, articular surface and bone pathologies of knee injuries.Results: MR images were normal in 15 patients; it was positive for meniscal tears in 59 patients and maximum involvement was in the medial meniscus and the posteriorhorn. These tears were classified into grade 1 (28.8%), grade 2 (11.5%), grade 3 (53.9%) and grade 4 (5.8%). Ligament tears were seen in 70 patients. Secondary signs associated with ligament tears were also assessed.Conclusions: MRI is an accurate, non-invasive technique for examination of the soft tissues and osseous structures of the knee. It has great capability in diagnosing meniscal tears and classifying them into grades and types, which would avoid unnecessary arthroscopic examination. It is a very good modality to diagnose complete tears of the anterior cruciate ligament (ACL).maging, meniscus
A chemical optical fiber sensor based on surface plasmon resonance (SPR) was developed and implemented using multimode plastic optical fiber. The sensor is used to detect and measure the refractive index and concentration of various chemical materials (Urea, Ammonia, Formaldehyde and Sulfuric acid) as well as to evaluate the performance parameters such as sensitivity, signal to noise ratio, resolution and figure of merit. It was noticed that the value of the sensitivity of the optical fiber-based SPR sensor, with 60nm and 10 mm long, Aluminum(Al) and Gold (Au) metals film exposed sensing region, was 4.4 μm, while the SNR was 0.20, figure of merit was 20 and resolution 0.00045. In this work a multimode
... Show MorePhotonic Crystal Fiber (PCF) based on the Surface Plasmon Resonance (SPR) effect has been proposed to detect polluted water samples. The sensing characteristics are illustrated using the finite element method. The right hole of the right side of PCF core has been coated with chemically stable gold material to achieve the practical sensing approach. The performance parameter of the proposed sensor is investigated in terms of wavelength sensitivity, amplitude sensitivity, sensor resolution, and linearity of the resonant wavelength with the variation of refractive index of analyte. In the sensing range of 1.33 to 1.3624, maximum sensitivities of 1360.2 nm ∕ RIU and 184 RIU−1 are achieved with the high sensor resolutions of 7
... Show MoreBackground: Skull secondary tumors are malignant bone tumors which are increasing in incidence.Objective: The objectives of this study were to present clinical features , asses the outcome of patients with secondary skull tumors ,characterize the MRI features, locations, and extent of secondary skull tumors to determine the frequency of the symptomatic disease.Type of the study: This is a prospective study.Methods: This is a prospective study from February 2000 to February 2008. The patients were selected from five neurosurgical centers and one oncology hospital in Baghdad/Iraq. The inclusion criteria were MRI study of the head(either as an initial radiological study or following head CT scan when secondary brain tumor is suspected , vis
... Show MoreThe platelet activity and some immunological aspects of
coronary heart disease CIID were investigated by employing platelet count and serum levels of IgG,IgM and lgA,C3 and C4.Three groups of patients were investigated : patients with ischemic heart disease IHD, patients with lliD+hypcrtension and patients with IHD+unstable angina.The results revealed that the mean of platelets (mm') was significantly reduced in IHD+unstable angina group
2.72.L I.l2 compared with conrol b'TOUp 8.13±2.72.
With respect to the immunological study, the re;;ults revea
... Show MoreAnalytical field target function has been considered to represent the axial magnetic field distribution of double polepiece symmetric magnetic lens. In this article, with aid of the proposed target function, the syntheses procedure is dependent. The effect of the main two coffectin optimization parameters on the lens field distribution, polepieces shape, and the objective focal prosperities for lenses operated under zero magnification mode has been studied. The results have shown that the objective properties evaluated in sense of the inverse design procedure are in an excellent correspondence with that of analysis approach. Where the optical properties enhance as the field distribution of the electron lens distributed along a narrow axi
... Show MoreThe Optical Fiber sensor based on the Surface Plasmon Resonance (SPR) technology has
been a successful performance sensing and presents high sensitivity. This thesis investigates the
performance of several structure of SPR sensor in field of refractive index and chemical
applications. A structure of Multi-Mode Fiber- Single Mode Fiber- Multi Mode Fiber (MMFSMF-MMF)
A Wearable Robotic Knee (WRK) is a mobile device designed to assist disabled individuals in moving freely in undefined environments without external support. An advanced controller is required to track the output trajectory of a WRK device in order to resolve uncertainties that are caused by modeling errors and external disturbances. During the performance of a task, disturbances are caused by changes in the external load and dynamic work conditions, such as by holding weights while performing the task. The aim of this study is to address these issues and enhance the performance of the output trajectory tracking goal using an adaptive robust controller based on the Radial Basis Function (RBF) Neural Network (NN) system and Hamilton
... Show MoreIn this paper, 3D simulation of the global coronal magnetic field, which use observed line of sight component of the photosphere magnetic field from (MDI/SOHO) was carried out using potential field model. The obtained results, improved the theoretical models of the coronal magnetic field, which represent a suitable lower boundary conditions (Bx, By, Bz) at the base of the linear force-free and nonlinear force free models, provides a less computationally expensive method than other models. Generally, very high speed computer and special configuration is needed to solve such problem as well as the problem of viewing the streamline of the magnetic field. For high accuracy special mathematical treatment was adopted to solve the computation comp
... Show MoreThe brief description to the theory of propagation of electromagnetic waves in plasma was done. The cutoff and resonance regions have been showed. The principles of plasma heating at electron cyclotron resonance (ECRH) method have been mentioned. The numerical simulation to three different station: Tosca station in United Kingdom, ISX-B station in USA and T-10 station in Russia had been done. The optical depth and the friction of energy absorbed A have been calculated. The simulation results indicate that both and A are increase with size of the tokamak and it is possible to obtain full absorption in large tokamak.