Background: The disc prolapse is a common condition especially in young adults. Different levels are affected in the lumber region; the L4/L5 disc is more susceptible to longitudinal load and is the most common site of lumbar disc prolapse. The L5/S1 disc is protected from torsion load by strong ilio-lumbar ligaments but it is more susceptible to axial compressive forces. Many factors affect the result and outcome of surgery in these levels.Objective: The aim of this study is to correlate operative data, short-term results, complications, and prognostic factors (age, gender, mobility, hospital stay, and level of pain) for one-level lumber discectomybetween different levels (L4–L5 vs. L5–S1).Methods In this prospective study, 32 patientsin Al-Yarmouk teaching hospital undergoing survey form March 2008-December 2012.Six patients were excluded from this study because they were diabetics and multilevel disc degeneration .Fifteen (57.6%) patients undergoL5-S1 discectomy and 11 (42.4%) patients undergoL4-5 discectomy. Questionnaires for leg and back pain intensity (Visual Analogue Scale ;VAS), duration of leg pain, and disability (Oswestry Disability Index; ODI), were obtained preoperatively, 3 months, 6 months, 1-year- and 2 year follow-up.Analyses were utilized to evaluate the relationship between surgical outcomes and variable (gender, age, lumber segment, pre-operative ODI, and pre-operative VAS).Results: Mean operative time was[73.44 ± 26.25] min, mean hospital stay was [3-7] days, and mean mobilitywas [2.55 ± 0.93] days. At 2-year follow up, patients revealed a statistical significant improvement inVAS pain (P < 0.05), and ODI lumbar function (P < 0.05).The complications rate were 20.3 %.Our study elaborates good results for one-segmental L5-S1overL4-L5 discectomy. Discectomy of the L4–L5 disc wasassociated with an increased risk of complication (P < 0.05). The comparison revealed that operative time was influenced by age (P = 0.034); hospital stay was influenced by level (P = 0.036) and pre-op VAS (P = 0.006); while complications were influenced by level (P = 0.001) and pre-op ODI (P = 0.049Conclusion: The study revealed significant results for L5-S1 discectomy over L4-L5 discectomy in the late follow up period; the complications rate were higher in L4-L5 level discectomy
Construction and operation of (2 m) parabolic solar dish for hot water application were illustrated. The heater was designed to supply hot water up to 100 oC using the clean solar thermal energy. The system includes the design and construction of solar tracking unit in order to increase system performance. Experimental test results, which obtained from clear and sunny day, refer to highly energy-conversion efficiency and promising a well-performed water heating system.
In the current study, haemoglobin analytes dissolved in a special buffer (KH2PO4(1M), K2HPO4(1M)) with pH of 7.4 were used to record absorption spectra measurements with a range of concentrations from (10-8 to 10-9) M and an absorption peak of 440nm using Broadband Cavity Enhanced Absorption Spectroscopy (BBCEAS) which is considered a simple, low cost, and robust setup. The principle work of this technique depends on the multiple reflections between the light source, which is represented by the Light Emitting Diode 3 W, and the detector, which is represented by the Avantes spectrophotomer. The optical cavity includes two high reflectivity ≥99% dielectric mirrors (dia
... Show MoreBased on a finite element analysis using Matlab coding, eigenvalue problem has been formulated and solved for the buckling analysis of non-prismatic columns. Different numbers of elements per column length have been used to assess the rate of convergence for the model. Then the proposed model has been used to determine the critical buckling load factor () for the idealized supported columns based on the comparison of their buckling loads with the corresponding hinge supported columns . Finally in this study the critical buckling factor () under end force (P) increases by about 3.71% with the tapered ratio increment of 10% for different end supported columns and the relationship between normalized critical load and slenderness ratio was g
... Show MoreGeneral Background: Deep image matting is a fundamental task in computer vision, enabling precise foreground extraction from complex backgrounds, with applications in augmented reality, computer graphics, and video processing. Specific Background: Despite advancements in deep learning-based methods, preserving fine details such as hair and transparency remains a challenge. Knowledge Gap: Existing approaches struggle with accuracy and efficiency, necessitating novel techniques to enhance matting precision. Aims: This study integrates deep learning with fusion techniques to improve alpha matte estimation, proposing a lightweight U-Net model incorporating color-space fusion and preprocessing. Results: Experiments using the AdobeComposition-1k
... Show MoreThis work represents development and implementation a programmable model for evaluating pumping technique and spectroscopic properties of solid state laser, as well as designing and constructing a suitable software program to simulate this techniques . A study of a new approach for Diode Pumped Solid State Laser systems (DPSSL), to build the optimum path technology and to manufacture a new solid state laser gain medium. From this model the threshold input power, output power optimum transmission, slop efficiency and available power were predicted. different systems configuration of diode pumped solid state laser for side pumping, end pump method using different shape type (rod,slab,disk) three main parameters are (energy transfer efficie
... Show More