Background: For various reasons, inguinal hernia repair under local anaesthesia is not well accepted to both patients and surgeons. The patients fear from pain and surgeons need full relaxation and co-operation to do successful hernia repairMethods: purpose of this study is to evaluate the effectiveness of local anaesthesia in inguinal hernia repair.prospective study was made from January 2011-0ctober 2013 , on a total of 50 patients with inguinal hernia operated on under local anaesthesia. Patients were selected primarily on the basis of their willingness to accept the procedure after the technique was described to them.Results: In this study 50 patient and 58 herniorrhaphies done for them during a period of about 34months were evaluated .A questionnaire was sent to each patient postoperatively to aid in evaluating the subjective reactionto the local anaesthesia. all patients were males ,age range between 31-83 year, median age 51 .types of inguinal hernia were sliding 1case ,pantaloon 5cases ,indirect 28cases ,direct 24 cases ,Rt. Side 27cases, Lt. side 15 cases ,bilateral hernia 8 cases .we give local anesthesia by 2 methodsConclusions: Local anesthesia is without question the safest available technique of anesthesia.Local anesthesia is an extension of the surgical procedure (indeed, often an integral part of that procedure), and as such its administration should be the concern of the surgeon
The steady state performance of the counter rotating floating ring Journal bearing is analyzed with isothermal finite bearing theory. The effect of different parameters affecting the performance of the bearing (namely speed ratio, clearance ratio and radii ratio), have been investigated. The load carrying capacity of the bearing increasing with decreasing the radii ratio (R2/R1) of the ring and clearance ratio (c1/c2), in the other hand, the coefficient of friction increases with increasing the clearance and radii ratios, while decreases with incre4asing the bearing to journal speed ratio (γ). It is shown during this work that different operating conditions are greatly enhanced the performance
... Show MoreAbstract:
The research sought to identify the crises that occurred during the research period and their reflection on the performance of the hotel Research sample as well as to identify the reality of auditing the hotel Research sample and the preparation of a performance audit program can be adopted in auditing the performance of hotels in light of crises, and the problem of the research lies in the lack of a program to audit the performance of hotels that takes into account the crises experienced by the hotel sector, The research was based on solving its problems on three hypotheses, the first is that the performance audit in light of the Covid-19 pand
... Show MoreIn Iraq most of the small buildings deployed a conventional air conditioning technology which typically uses electrically driven compressor systems which exhibits several clear disadvantages such as high energy consumption, high electricity at peak loads. In this work a thermal performance of air conditioning system combined with a solar collector is investigated theoretically. The hybrid air conditioner consists of a semi hermetic compressor, water cooled shell and tube condenser, thermal expansion valve and coil with tank evaporator. The theoretical analysis included a simulation for the solar assisted air-conditioning system using EES software to analyze the effect of different parameters on the power consumption of c
... Show MoreThis study investigates the implementation of Taguchi design in the estimation of minimum corrosion rate of mild-steel in cooling tower that uses saline solution of different concentration. The experiments were set on the basis of Taguchi’s L16 orthogonal array. The runs were carried out under different condition such as inlet concentration of saline solution, temperature, and flowrate. The Signal-to- Noise ratio and ANOVA analysis were used to define the impact of cooling tower working conditions on the corrosion rate. A regression had been modelled and optimized to identify the optimum level for the working parameters that had been founded to be 13%NaCl, 35ᴼC, and 1 l/min. Also a confirmation run to establish the p
... Show MoreThe insulation system of a machine coil includes several layers made of materials with different characteristics. The effective insulation design of machine coils, especially in the machine end winding, depends upon an accurate model of the stress grading system. This paper proposes a modeling approach to predict the transient overvoltage, electric field, and heat generation in machine coils with a stress grading system, considering the variation of physical properties in the insulation layers. A non-uniform line model is used to divide the coil in different segments based on material properties and lengths: overhang, stress grading and slot. The cascaded connection of chain matrices is used to connect segments for the representation of the
... Show MoreReducing a structure’s self-weight is the main goal and a major challenge for most civil constructions, especially in tall buildings and earthquake-affected buildings. One of the most adopted techniques to reduce the self-weight of concrete structures is applying voids in certain positions through the structure, just like a voided slab or BubbleDeck slab. This research aims to study, experimentally and theoretically, the structural behavior of BubbleDeck reinforced concrete slabs under the effect of harmonic load. Tow-way BubbleDeck slab of 2500mm×2500m×200mm dimensions and uniformly distributed bubbles of 120mm diameter and 160mm spacing c/c was tested experimentally under the effect of harmonic load. Numerical analysis was als
... Show MorePultruded materials made of Fiber-Reinforced Polymer (FRP) come in a broad range of shapes, such as bars, I-sections, C-sections, etc. FRP materials are starting to compete with steel as structural materials owing to their great resistance, low self-weight, and cheap maintenance costs, especially in corrosive conditions. This study aims to evaluate the effectiveness of a novel concrete Composite Column (CC) using Encased I-Section (EIS) as a reinforcement in contrast to traditional steel bars by using Glass Fiber-Reinforced Polymer (GFRP) as I-section (CC-EIS) to evaluate the effectiveness of the hybrid columns which have been built by combining GFRP profiles with concrete columns. To achieve the aims of this study, nine circular co
... Show More