Preferred Language
Articles
/
jkmc-365
Application of Alvarado scoring system in the diagnosis of acute appendicitis.
...Show More Authors

Background: Acute appendicitis is the most common abdominal surgical emergency. The diagnosis of this condition is still essentially clinical and there is difficulty in the clinical diagnosis, especially among elderly, children and patients with a typical presentation, so early and accurate diagnosis of acute appendicitis is important to avoid its complications.Objectives: To evaluate the degree of accuracy of Alvarado scoring system in the diagnosis of acute appendicitis.Method: Two hundred patients were admitted to the Alkindy Teaching Hospital from January 2011 to april 2014- presented with symptoms and signs suggestive of acute appendicitis. After examination and investigations all patients were given a score according to Alvarado scoring 10 (8 variables) and they were classified accordingly to 6 groups of scores (score 5, score 6, score 7, score 8, score 9 and score 10). All the patients underwent appendectomy and the appendix specimens were sent for histopathological examination and the patients were divided into two groups:1-patients 7 score (164 patients)2-patients <7 score (36 patients)-We calculate the percentage of appendix proved to be inflamed by histopathology in each group of these 6 scoring groups.Results: The patients ages range from (7-64 years).One hundred six patients were male, 94 patients were female with male: female ratio of 1.24:1.Out of 200 patients, 168 patients had inflamed appendix proved by histopathological study, including 93 male and 75 female, while 32 patients have a normal appendix (13 male, 19 female).The Alvarado sensitivity found to be 83%, specificity is 59%, diagnostic accuracy of 85%, positive predictive value of 92% and negative predictive value of 59%.The diagnostic accuracy of the Alvarado score was found to be increased with the increase in the Alvarado score as it was 81% with Alvarado score 7 it was 100% in Alvarado score 10.Conclusion : Alvarado scoring system is a useful tool in diagnosis of acute appendicitis because it is simple, with high diagnostic accuracy rate and this accuracy increase proportionally to the increase in the degree of the score.Alvarado scoring system is a useful tool in diagnosis of acute appendicitis because it is simple, with high diagnostic accuracy rate and this accuracy increase proportionally to the increase in the degree of the score

View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Nov 29 2018
Journal Name
Iraqi Journal Of Science
A new Color image Encryption based on multi Chaotic Maps
...Show More Authors

     This paper presents a new RGB image encryption scheme using multi chaotic maps. Encrypting an image is performed via chaotic maps to confirm the properties of secure cipher namely confusion and diffusion are satisfied. Also, the key sequence for encrypting an image is generated using a combination of   1D logistic and Sine chaotic maps. Experimental results and the compassion results indicate that the suggested scheme provides high security against several types of attack, large secret keyspace and highly sensitive.   

View Publication Preview PDF
Publication Date
Mon Jul 01 2024
Journal Name
المجلة العلمية لعلوم وفنون الرياضة
العلاقة بين طول الذراع وبعض المتغيرات البايوكينماتيكية في سباحة الفراشة (50 متر) لسباحي المنتخب الوطني
...Show More Authors

Competitive swimming is a highly researched area and technological developments have aided advances in the understanding of the biomechanical principles that underpin these elements and govern propulsion. Moreover, those working in the sports field especially in swimming are interested in studying, analyzing, evaluating and developing motor skills by diagnosing the strengths and weaknesses of the skill, and accordingly, coaches and specialists correct these errors. The researchers chose this (Butterfly swimming) and the (arm length) is an important variable because the success of the stroke is greatly dependent on the propulsion generated from the arm pull, and swimmers with a longer arm span have a mechanical advantage with the resulting f

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Jul 29 2020
Journal Name
Iraqi Journal Of Science
Fractal Image Compression Using Block Indexing Technique: A Review
...Show More Authors

Fractal image compression depends on representing an image using affine transformations. The main concern for researches in the discipline of fractal image compression (FIC) algorithm is to decrease encoding time needed to compress image data. The basic technique is that each portion of the image is similar to other portions of the same image. In this process, there are many models that were developed. The presence of fractals was initially noticed and handled using Iterated Function System (IFS); that is used for encoding images. In this paper, a review of fractal image compression is discussed with its variants along with other techniques. A summarized review of contributions is achieved to determine the fulfillment of fractal image co

... Show More
View Publication Preview PDF
Scopus (5)
Crossref (1)
Scopus Crossref
Publication Date
Thu Dec 28 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Synthesis and Characterization of some Metal Complexes with (3Z ,5Z, 8Z)-2-azido-8-[azido(3Z,5Z)-2-azido-2,6bis(azidocarbonyl)-8,9-dihydro-2H-1,7-dioxa-3,4,5triazonine-9-yl]methyl]-9-[(1-azido-1-hydroxy)methyl]-2H1,7-dioxa-3,4,5-triazonine – 2,6 – dica
...Show More Authors

  The reaction of LAs-Cl8 : [ (2,2- (1-(3,4-bis(carboxylicdichloromethoxy)-5-oxo-2,5dihydrofuran-2-yl)ethane – 1,2-diyl)bis(2,2-dichloroacetic acid)]with sodium azide in ethanol with drops of distilled water has been investigated . The new product L-AZ :(3Z ,5Z,8Z)-2azido-8-[azido(3Z,5Z)-2-azido-2,6-bis(azidocarbonyl)-8,9-dihydro-2H-1,7-dioxa-3,4,5triazonine-9-yl]methyl]-9-[(1-azido-1-hydroxy)methyl]-2H-1,7-dioxa-3,4,5-triazonine – 2,6 – dicarbonylazide was isolated and characterized by elemental analysis (C.H.N) , 1H-NMR , Mass spectrum and Fourier transform infrared spectrophotometer (FT-IR) . The reaction of the L-AZ withM+n: [ ( VO(II) , Cr(III)  ,Mn(II) , Co(II) , Ni(II) , Cu(II) , Zn(II) , Cd(II) and

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat May 07 2016
Journal Name
International Journal Of Science And Research
Synthesis, Characterization and Antimicrobial Activity Studies of Mixed-1,10-phenanthroline- Mn(II),Co(II), Cu(II), Ni(II) and Hg(II) Complexes with Schiff Base[2,2'-(1Z,1'Z)-(biphenyl-4,4'- diylbis(azan-1-yl-1-ylidene))bis(methan-1-yl-1- ylidene)diphenol]
...Show More Authors

Abstract: The M(II) complexes [M2(phen)2(L)(H2O)2Cl2] in (2:1:2 (M:L:phen) molar ratio, (where M(II) =Mn(II), Co(II), Cu(II), Ni(II) and Hg(II), phen = 1,10-phenanthroline; L = 2,2'-(1Z,1'Z)-(biphenyl-4,4'-diylbis(azan-1-yl-1-ylidene))bis(methan-1-yl-1- ylidene)diphenol] were synthesized. The mixed complexes have been prepared and characterized using 1H and13C NMR, UV/Visible, FTIR spectra methods and elemental microanalysis, as well as magnetic susceptibility and conductivity measurements. The metal complexes were tested in vitro against three types of pathogenic bacteria microorganisms: Staphylococcus aurous, Escherichia coli, Bacillussubtilis and Pseudomonasaeroginosa to assess their antimicrobial properties. From this study shows that a

... Show More
Preview PDF
Publication Date
Sat Apr 01 2023
Journal Name
Baghdad Science Journal
Interior Visual Intruders Detection Module Based on Multi-Connect Architecture MCA Associative Memory
...Show More Authors

Most recent studies have focused on using modern intelligent techniques spatially, such as those
developed in the Intruder Detection Module (IDS). Such techniques have been built based on modern
artificial intelligence-based modules. Those modules act like a human brain. Thus, they should have had the
ability to learn and recognize what they had learned. The importance of developing such systems came after
the requests of customers and establishments to preserve their properties and avoid intruders’ damage. This
would be provided by an intelligent module that ensures the correct alarm. Thus, an interior visual intruder
detection module depending on Multi-Connect Architecture Associative Memory (MCA)

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Tue Sep 08 2020
Journal Name
Baghdad Science Journal
CTJ: Input-Output Based Relation Combinatorial Testing Strategy Using Jaya Algorithm
...Show More Authors

Software testing is a vital part of the software development life cycle. In many cases, the system under test has more than one input making the testing efforts for every exhaustive combination impossible (i.e. the time of execution of the test case can be outrageously long). Combinatorial testing offers an alternative to exhaustive testing via considering the interaction of input values for every t-way combination between parameters. Combinatorial testing can be divided into three types which are uniform strength interaction, variable strength interaction and input-output based relation (IOR). IOR combinatorial testing only tests for the important combinations selected by the tester. Most of the researches in combinatorial testing appli

... Show More
View Publication Preview PDF
Scopus (10)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Thu Feb 01 2018
Journal Name
Journal Of Engineering
Synchronous Buck Converter with Perturb and Observe Maximum Power Point Tracking Implemented on a Low-Cost Arduino-microcontroller
...Show More Authors

Maximum power point tracking (MPPT) is used in photovoltaic (PV) systems to enhance efficiency and maximize the output power of PV module, regardless the variation of temperature, irradiation, and the electrical characteristics of the load. A new MPPT system has been presented in this research, consisting of a synchronous DC-DC step-down Buck converter controlled by an Arduino microcontroller based unit. The MPPT process with Perturb and Observe method is performed with a DC-DC converter circuit to overcome the problem of voltage mismatch between the PV modules and the loads. The proposing system has high efficiency, lower cost and can be easily modified to handle more energy sources. The test results indicate that the u

... Show More
View Publication Preview PDF
Publication Date
Wed Jan 11 2017
Journal Name
Journal: Ibn Al-haitham Journal For Pure And Applied Sciences
Synthesis and Characterization of some Metal Complexes with (3Z ,5Z, 8Z)-2-azido-8-[azido(3Z,5Z)-2-azido-2,6- bis(azidocarbonyl)-8,9-dihydro-2H-1,7-dioxa-3,4,5- triazonine-9-yl]methyl]-9-[(1-azido-1-hydroxy)methyl]-2H1,7-dioxa-3,4,5-triazonine – 2,6 – dicarbonylazide(L-AZ) .
...Show More Authors

The reaction of LAs-Cl8 : [ (2,2- (1-(3,4-bis(carboxylicdichloromethoxy)-5-oxo-2,5- dihydrofuran-2-yl)ethane – 1,2-diyl)bis(2,2-dichloroacetic acid)]with sodium azide in ethanol with drops of distilled water has been investigated . The new product L-AZ :(3Z ,5Z,8Z)-2- azido-8-[azido(3Z,5Z)-2-azido-2,6-bis(azidocarbonyl)-8,9-dihydro-2H-1,7-dioxa-3,4,5- triazonine-9-yl]methyl]-9-[(1-azido-1-hydroxy)methyl]-2H-1,7-dioxa-3,4,5-triazonine – 2,6 – dicarbonylazide was isolated and characterized by elemental analysis (C.H.N) , 1H-NMR , Mass spectrum and Fourier transform infrared spectrophotometer (FT-IR) . The reaction of the L-AZ withM+n: [ ( VO(II) , Cr(III) ,Mn(II) , Co(II) , Ni(II) , Cu(II) , Zn(II) , Cd(II) and Hg(II)] has been i

... Show More
Publication Date
Wed Dec 18 2019
Journal Name
Baghdad Science Journal
Structural and Optical Properties for Nanostructure (Ag2O/Si & Psi) Films for Photodetector Applications
...Show More Authors

Ag2O (Silver Oxide) is an important p-type (in chasm to most oxides which were n-type), with a high conductivity semiconductor. From the optical absorbance data, the energy gap value of the Ag2O thin films was 1.93 eV, where this value substantially depends on the production method, vacuum evaporation of silver, and optical properties of Ag2O thin films are also affected by the precipitation conditions. The n-type and p-type silicon substrates were used  with porous silicon wafers to precipitate  ±125 nm, as thick Ag2O thin film by thermal evaporation techniques in vacuum and via rapid thermal oxidation of 400oC and oxidation time 95 s, then characterized by measurement of

... Show More
View Publication Preview PDF
Scopus (8)
Crossref (7)
Scopus Clarivate Crossref