Preferred Language
Articles
/
jkmc-365
Application of Alvarado scoring system in the diagnosis of acute appendicitis.
...Show More Authors

Background: Acute appendicitis is the most common abdominal surgical emergency. The diagnosis of this condition is still essentially clinical and there is difficulty in the clinical diagnosis, especially among elderly, children and patients with a typical presentation, so early and accurate diagnosis of acute appendicitis is important to avoid its complications.Objectives: To evaluate the degree of accuracy of Alvarado scoring system in the diagnosis of acute appendicitis.Method: Two hundred patients were admitted to the Alkindy Teaching Hospital from January 2011 to april 2014- presented with symptoms and signs suggestive of acute appendicitis. After examination and investigations all patients were given a score according to Alvarado scoring 10 (8 variables) and they were classified accordingly to 6 groups of scores (score 5, score 6, score 7, score 8, score 9 and score 10). All the patients underwent appendectomy and the appendix specimens were sent for histopathological examination and the patients were divided into two groups:1-patients 7 score (164 patients)2-patients <7 score (36 patients)-We calculate the percentage of appendix proved to be inflamed by histopathology in each group of these 6 scoring groups.Results: The patients ages range from (7-64 years).One hundred six patients were male, 94 patients were female with male: female ratio of 1.24:1.Out of 200 patients, 168 patients had inflamed appendix proved by histopathological study, including 93 male and 75 female, while 32 patients have a normal appendix (13 male, 19 female).The Alvarado sensitivity found to be 83%, specificity is 59%, diagnostic accuracy of 85%, positive predictive value of 92% and negative predictive value of 59%.The diagnostic accuracy of the Alvarado score was found to be increased with the increase in the Alvarado score as it was 81% with Alvarado score 7 it was 100% in Alvarado score 10.Conclusion : Alvarado scoring system is a useful tool in diagnosis of acute appendicitis because it is simple, with high diagnostic accuracy rate and this accuracy increase proportionally to the increase in the degree of the score.Alvarado scoring system is a useful tool in diagnosis of acute appendicitis because it is simple, with high diagnostic accuracy rate and this accuracy increase proportionally to the increase in the degree of the score

View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Aug 22 2023
Journal Name
Advances In Structural Engineering
Experimental and finite element analysis of reinforced concrete multi-cell box girders retrofitted with carbon fiber reinforced polymer strips under torsion
...Show More Authors

This study expands the state of the art in studies that assess torsional retrofit of reinforced concrete (RC) multi-cell box girders with carbon fiber reinforced polymer (CFRP) strips. The torsional behavior of non-damaged and pre-damaged RC multi-cell box girder specimens externally retrofitted by CFRP strips was investigated through a series of laboratory experiments. It was found that retrofitting the pre-damaged specimens with CFRP strips increased the ultimate torsional capacity by more than 50% as compared to the un-damaged specimens subjected to equivalent retrofitting. This indicated that the retrofit has been less effective for the girder specimen that did not develop distortion beforehand as a result of pre-loading. From

... Show More
View Publication
Scopus (9)
Crossref (8)
Scopus Clarivate Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Colloids And Surfaces A: Physicochemical And Engineering Aspects
Studies on membrane stability and extraction of ciprofloxacin from aqueous solution using pickering emulsion liquid membrane stabilized by magnetic nano-Fe2O3
...Show More Authors

View Publication
Scopus (54)
Crossref (48)
Scopus Clarivate Crossref
Publication Date
Fri Jul 19 2024
Journal Name
Applied Science And Engineering Progress
Multicomponent Equilibrium Isotherms and Kinetics Study of Heavy Metals Removal from Aqueous Solutions Using Electrocoagulation Combined with Mordenite Zeolite and Ultrasonication
...Show More Authors

Combining different treatment strategies successively or simultaneously has become recommended to achieve high purification standards for the treated discharged water. The current work focused on combining electrocoagulation, ion-exchange, and ultrasonication treatment approaches for the simultaneous removal of copper, nickel, and zinc ions from water. The removal of the three studied ions was significantly enhanced by increasing the power density (4–10 mA/cm2) and NaCl salt concentration (0.5–1.5 g/L) at a natural solution pH. The simultaneous removal of these metal ions at 4 mA/cm2 and 1 g NaCl/L was highly improved by introducing 1 g/L of mordenite zeolite as an ion-exchanger. A remarkable removal of heavy metals was reported

... Show More
View Publication
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Mon May 01 2023
Journal Name
Chemical Engineering Research And Design
Treatment of petroleum refinery wastewater by electrofenton process using a low cost porous graphite air-diffusion cathode with a novel design
...Show More Authors

View Publication
Scopus (30)
Crossref (30)
Scopus Clarivate Crossref
Publication Date
Fri Sep 01 2023
Journal Name
Al-khwarizmi Engineering Journal
Green Fabrication and Characterization of Zinc Oxide Nanoparticles using Eucalyptus Leaves for Removing Acid Black 210 Dye from an Aqueous Medium
...Show More Authors

This study uses an environmentally friendly and low-cost synthesis method to manufacture zinc oxide nanoparticles (ZnO NPs) by using zinc sulfate. Eucalyptus leaf extract is an effective chelating and capping agent for synthesizing ZnO NPs. The structure, morphology, thermal behavior, chemical composition, and optical properties of ZnO nanoparticles were studied utilizing FT-IR, FE-SEM, EDAX, AFM, and Zeta potential analysis. The FE-SEM pictures confirmed that the ZnO NPs with a size range of (22-37) nm were crystalline and spherical. Two methods were used to prepare ZnO NPs. The first method involved calcining the resulting ZnO NPs, while the second method did not. The prepared ZnO NPs were used as adsorbents for removing acid black 210

... Show More
View Publication Preview PDF
Scopus (6)
Crossref (4)
Scopus Crossref
Publication Date
Thu Dec 14 2023
Journal Name
Optical And Quantum Electronics
Enhancing response characteristics of palladium-doped vanadium pentoxide on a porous silicon substrate as gas sensor synthesized by pulsed laser deposition
...Show More Authors

View Publication
Scopus (3)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Thu Aug 01 2024
Journal Name
Baghdad Science Journal
Synthesis, Structural, Morphological Characterization, and Cytotoxicity Assays of Metal Complexes Decorated SiO2 Nanoparticles Against Breast Cancer Cell Lines (MDA-MB-231)
...Show More Authors

في هذا البحث تم تحضير المركبات المعدنية الجديدة لأيونات البلاتين (الرباعي) و الذهب (الثلاثي) مع ليكاند قاعدة مانخ جديد مشتق من السيبروفلوكساسين . تم استخدام المعقدات بعد ذلك كمصدر  لتحضير جزيئات                              عن طريق ترسيب المعقدات على مسام دقائق السيليكا النانوية.                                                                      Si/Au2O3 Si/PtO2  تم تشخيص الليكاند و معقداته

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Sun Jun 05 2022
Journal Name
Egyptian Journal Of Chemistry
Synthesis, Characterization, and Biological Activity of New Metal Ions Complexes with Schiff Base Derived from 2-Acetylthiophene and Isatin-3-Hydrazone
...Show More Authors

This study describes the preparation of a new bidentate Schiff base derived from the condensation of Isatin-3-hydrazone with 2-acetylthiophene and the preparation of new series of complexes with a good yield. The prepared ligand was characterized by IR, UV-Vis, C.H.N.S elemental analysis, 1H and 13C NMR, LC-Mass spectroscopy, and physical measurements. Its complexes were analyzed by C.H.N.S elemental analyses, UV-Vis., FTIR, NMR, LC-Mass Spectra, atomic absorption spectroscopy, magnetic susceptibility, and conductivity measurements The results from spectroscopy and measurement studies showed that the ligand coordinated to the metal ion as a bidentate ligand via oxygen and nitrogen, forming an octahedral geometry around it. In vitro antimicr

... Show More
Publication Date
Sat Dec 20 2025
Journal Name
Bulletin Of The Iraq Natural History Museum
MORPHOLOGICAL AND MOLECULAR DESCRIPTION FOR A NEW RECORD OF NEMATODE ACROBELOIDES VARIUS KIM, KIM &amp; PARK, 2017 (RHABDITIDA, CEPHALOBIDAE) FROM IRAQ
...Show More Authors

This study aimed to identify and describe one of the bacterial feeder nematode Acrobeloides varius Kim, Kim and Park, 2017 (Rhabditida, Cephalobidae), which was isolated from soil samples that were collected from Baghdad, central of Iraq, and was classified using both morphological and molecular criteria. All specimens of A. varius were cultured, identified and described using morphometric criteria. Selected specimens (Zah. IRQ3 OR994579.1 isolate) of this species were characterized by having the body length of the male ranging from (184.94 – 221.72 μm), the body length of the female ranging (507.38 – 521.92 μm) and the body length of the juvenile ranging from (355.53 – 490.35 μm). Selected specimens of this species were m

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed May 10 2023
Journal Name
Journal Of Engineering
REMOVAL OF PHENOLIC COMPUNDS FROM AQUEOUS SOLUTIONS BY ADSOPTION ONTO ACTIVTED CARBONS PREPARED FROM DATE STONES BY CHEMICAL ACTIVATION WITH FeCl3
...Show More Authors

Activated carbon prepared from date stones by chemical activation with ferric chloride (FAC) was used an adsorbent to remove phenolic compounds such as phenol (Ph) and p-nitro phenol (PNPh) from aqueous solutions. The influence of process variables represented by solution pH value (2-12), adsorbent to adsorbate weight ratio (0.2-1.8), and contact time (30-150 min) on removal percentage and adsorbed amount of Ph and PNPh onto FAC was studied. For PNPh adsorption,( 97.43 %) maximum removal percentage and (48.71 mg/g) adsorbed amount was achieved at (5) solution pH,( 1) adsorbent to adsorbate weight ratio, and (90 min) contact time. While for Ph adsorption, at (4) solution pH, (1.4) absorbent to adsorbate weight ratio, and (120 min) contact

... Show More
View Publication Preview PDF
Crossref (4)
Crossref