Preferred Language
Articles
/
jkmc-365
Application of Alvarado scoring system in the diagnosis of acute appendicitis.
...Show More Authors

Background: Acute appendicitis is the most common abdominal surgical emergency. The diagnosis of this condition is still essentially clinical and there is difficulty in the clinical diagnosis, especially among elderly, children and patients with a typical presentation, so early and accurate diagnosis of acute appendicitis is important to avoid its complications.Objectives: To evaluate the degree of accuracy of Alvarado scoring system in the diagnosis of acute appendicitis.Method: Two hundred patients were admitted to the Alkindy Teaching Hospital from January 2011 to april 2014- presented with symptoms and signs suggestive of acute appendicitis. After examination and investigations all patients were given a score according to Alvarado scoring 10 (8 variables) and they were classified accordingly to 6 groups of scores (score 5, score 6, score 7, score 8, score 9 and score 10). All the patients underwent appendectomy and the appendix specimens were sent for histopathological examination and the patients were divided into two groups:1-patients 7 score (164 patients)2-patients <7 score (36 patients)-We calculate the percentage of appendix proved to be inflamed by histopathology in each group of these 6 scoring groups.Results: The patients ages range from (7-64 years).One hundred six patients were male, 94 patients were female with male: female ratio of 1.24:1.Out of 200 patients, 168 patients had inflamed appendix proved by histopathological study, including 93 male and 75 female, while 32 patients have a normal appendix (13 male, 19 female).The Alvarado sensitivity found to be 83%, specificity is 59%, diagnostic accuracy of 85%, positive predictive value of 92% and negative predictive value of 59%.The diagnostic accuracy of the Alvarado score was found to be increased with the increase in the Alvarado score as it was 81% with Alvarado score 7 it was 100% in Alvarado score 10.Conclusion : Alvarado scoring system is a useful tool in diagnosis of acute appendicitis because it is simple, with high diagnostic accuracy rate and this accuracy increase proportionally to the increase in the degree of the score.Alvarado scoring system is a useful tool in diagnosis of acute appendicitis because it is simple, with high diagnostic accuracy rate and this accuracy increase proportionally to the increase in the degree of the score

View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Sep 01 2015
Journal Name
Journal Of Engineering
Cost of Optimum Design of Trunk Mains Network Using Geographical Information System and Support Programs
...Show More Authors

Sewer network is one of the important utilities in modern cities which discharge the sewage from all facilities. The increase of population numbers consequently leads to the increase in water consumption; hence waste water generation. Sewer networks work is very expensive and need to be designed accurately. Thus construction effective sewer network system with minimum cost is very necessary to handle waste water generation.

 In this study trunk mains networks design was applied which connect the pump stations together by underground pipes for too long distances. They usually have large diameters with varying depths which consequently need excavations and gathering from pump stations and transport the sewage

... Show More
View Publication Preview PDF
Publication Date
Wed May 31 2017
Journal Name
Journal Of Engineering
Design and Implementation of Classical Sliding Mode Controller for Ball and Plate System
...Show More Authors

Ball and Plate (B&P) system is a benchmark system in the control engineering field that has been used to verify many control methods. In this paper the design of a sliding mode . controller has been investigated and verified in real-time via implementation on a real ball and plate system hardware. The mathematical model has been derived and the necessary parameters have been measured. The sliding mode controller has been designed based on the obtained mathematical model. The resulting controller has been implemented using the Arduino Mega 2560 and a ball and plate system built completely from scratch. The Arduino has been programmed by the Arduino support target for Simulink. Three test signals has been used for verification purposes

... Show More
View Publication Preview PDF
Publication Date
Thu Oct 31 2013
Journal Name
Al-khwarizmi Engineering Journal
Enhancement of a Power System Transient Stability Using Static Synchronous Series Compensator SSSC
...Show More Authors

Static Synchronous Series Compensator (SSSC) is a well known device for effectively regulating the active power flow in a power system. In this paper, the SSSC linearized power flow equations are incorporated into Newton-Raphson algorithm in a MATLAB written program to investigate the control of active poweer flow and the transient stability of a five bus and a thirty bus IEEE test systems, during abnormal conduction (three phase fault near buses). A comparison of the results obtained for the base case without SSSC and with it to investigate the effectiveness of the device on both of the active power flow and the transient stability.

View Publication Preview PDF
Publication Date
Sun Jan 01 2017
Journal Name
Proceeding Of The 1st International Conference On Recent Trends Of Engineering Sciences And Sustainability
Design of a Fractional Order Sliding Mode Controller for Twin Rotor Aerodynamic System
...Show More Authors

This paper proposes a new structure for a Fractional Order Sliding Mode Controller (FOSMC) to control a Twin Rotor Aerodynamic System (TRAS). The new structure is composed by defining two 3-dimensional sliding mode surfaces for the TRAS model and introducing fractional order derivative integral in the state variables as well as in the control action. The parameters of the controller are determined so as to minimize the Integral of Time multiplied by Absolute Error (ITAE) performance index. Through comparison, this controller outperforms its integer counterpart in many specifications, such as reducing the delay time, rise time, percentage overshoot, settling time, time to reach the sliding surface, and amplitude of chattering in control inpu

... Show More
Publication Date
Wed Mar 18 2020
Journal Name
Baghdad Science Journal
A Software Defined Network of Video Surveillance System Based on Enhanced Routing Algorithms
...Show More Authors

Software Defined Network (SDN) is a new technology that separate the ‎control plane from the data plane. SDN provides a choice in automation and ‎programmability faster than traditional network. It supports the ‎Quality of Service (QoS) for video surveillance application. One of most ‎significant issues in video surveillance is how to find the best path for routing the packets ‎between the source (IP cameras) and destination (monitoring center). The ‎video surveillance system requires fast transmission and reliable delivery ‎and high QoS. To improve the QoS and to achieve the optimal path, the ‎SDN architecture is used in this paper. In addition, different routing algorithms are ‎used with different steps. First, we eva

... Show More
View Publication Preview PDF
Scopus (5)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Sat Jan 09 2021
Journal Name
Journal Of Control, Automation And Electrical Systems
Design of an Adaptive Linear Quadratic Regulator for a Twin Rotor Aerodynamic System
...Show More Authors

View Publication
Scopus (6)
Crossref (8)
Scopus Clarivate Crossref
Publication Date
Wed Apr 05 2023
Journal Name
Journal Of Engineering
Performance Evaluation of Small Scale Air-Conditioning System Using R22 and Alternative Refrigerants
...Show More Authors

A mathematical model has been formulated to predict the influence of high outdoor air temperature on the performance of small scale air - conditioning system using R22 and alternative refrigerants R290, R407C, R410A. All refrigerants were investigated in the cooling mode operation. The mathematical model results have been validated with experimental data extracted from split type air conditioner of 2 TR capacity. This entailed the construction of an experimental test rig which consists of four main parts. They are, the refrigeration system, psychrometric test facility, measuring instrumentation, and auxiliary systems. The conditioned air was maintained at 25 0C dry bulb and 19 0C wet bulb for all tests. The outdoor ambient air temperatur

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Thu Aug 31 2017
Journal Name
Journal Of Engineering
Enhanced Performance of Consensus Wireless Sensor Controlled System via Particle Swarm Optimization Algorithm
...Show More Authors

     This paper describes the application of consensus optimization for Wireless Sensor Network (WSN) system. Consensus algorithm is usually conducted within a certain number of iterations for a given graph topology. Nevertheless, the best Number of Iterations (NOI) to reach consensus is varied in accordance with any change in number of nodes or other parameters of . graph topology. As a result, a time consuming trial and error procedure will necessary be applied
to obtain best NOI. The implementation of an intellig ent optimization can effectively help to get the optimal NOI. The performance of the consensus algorithm has considerably been improved by the inclusion of Particle Swarm Optimization (PSO). As a case s

... Show More
View Publication Preview PDF
Publication Date
Mon Jan 25 2021
Journal Name
Engineering And Technology Journal
Performance evaluation of Photovoltaic Panels by a Proposed Automated System Based on Microcontrollers
...Show More Authors

View Publication
Crossref (1)
Crossref
Publication Date
Sat Feb 05 2011
Journal Name
International Journal Of Chemical Reactor Engineering
Mass Transport Properties of a Flow-Through Electrolytic Reactor Using Zinc Reduction System
...Show More Authors

An electrolytic process for the removal of Zn(II) from aqueous solution using a parallel amalgamated copper screens cathode operated in the flow through mode is proposed. The current-potential curves recorded at a rotating amalgamated copper disc electrode were used to determine diffusion coefficient of Zn(II). The performance of electrolytic reactor was investigated by using different flow rates at initial zinc ion concentration(48 mg/L). Taking into account the residential Zn(II) concentration, the best results were obtained for cathode potential of (-1.35 V vs. SCE) at flow rate (320 L/h). Zinc ion concentration was found to decrease from 48 mg/L to 1 mg/L during 120 min. of electrolysis. The experimental data are well correlate

... Show More
View Publication
Crossref