Background: Transradial compared to classic transfemoral coronary intervention has been shown to have similar efficacy rates, while being more cost-effective and most importantly safer due to fewer access site complications. Furthermore, patient comfort is increased and outpatient treatment may be feasible..Objectives: To start trans-radial intervention program and the initial learning curve for fellows and the catheterization –laboratory nursing staff. To test how could it be applicable and comfortable for our patientsMethods: This prospective study was performed in Ibn-Albitar hospital for cardiac surgery over a period of 6 months from the 1st of August 2012 till the 1st of February 2013. Every patient referred for percutenuos coronary intervention whether on scheduled or on an emergency basis was considered initially for trans-radial approach for intervention unless they are excluded. Allen test was required ensuring adequate ullnar collateral supply. Sledinger technique was used for radial artery puncture and a special radial sheath was introduced. Intervention was performed through the same catheter and equipments that are used for femoral approach.. medication given according to center protocol, the relevant data collected and patients immediately ambulated unless they receive sedation.Results: A total of 126 patients were referred for intervention during the study period, 20 cases were excluded for various reasons , 6caese were crossed over to femoral approach and the other 100 cases the procedure completed transradially. The mean age of the patients was 57 ± 8 years. Of these 72% were males ,with different risk factors . Most cases presented with chronic stable angiana (87%). Access site was right radial artery in 87% of patients while left radial approach used in 13% of patients. In 72% of cases single guiding catheter was used, in 21% of cases 2 guiding catheter were used and more than 2 types of guiding catheter were used in 7% of cases. In most session of intervention single artery was treated (78%) , 2 vessel intervention in 21%, 3 vessel in one case..Lesions treated were different types 26%,36%,38% A,B and C respectively. The success in obtaining radial access was 97.7% ,while angiographic procedural success rate was 96%. Mean total procedure time was ( 43+/-23min ), mean fluoroscopy time (13+/-8 min )and the average amount of contrast used was (178+/-80ml). with no major complication apart from 3% small heamatom and 6% radial loss. Around 80% of patients preferred TRI approach.Conclusion: Radial artery approach for percutenuos coronary interventions has high procedural success rate and associated with low risk of access site complications and no significant increase of procedural and fluoroscopy time. It is comfortable approach for most patients especially female and obese. Early ambulation with no risk of bleeding and reduction of the duration of hospital stay are in favor of TRI approach.
This study aims to impact statement played by banking governance according to the decisions of the Basel Committee in achieving the strategic objectives of the banks, But order to achieve the this goal has been the adoption of two hypotheses in addition to the two main hypotheses as sub answered preliminary The study seeks to verify their health and two (no correlation relationship and impact between Banking governance and achieve strategic objectives), has been tested hypotheses. Study has reached
... Show MoreBackground: Maxillary first premolar with wide MOD cavity more susceptible to fracture. The aim of this study was to assess the influence of cavity design for cusp coverage on the fracture resistance of weakened maxillary first premolar restored with CAD/CAM hybrid ceramic versus nanohybide composite. Materials and Methods: Fifty six intact maxillary first premolars of approximately comparable sizes were divided into seven groups eight for each: Group A: Intact teeth (control group); Group B: teeth prepared for MOD inlay; Group C: teeth prepared for MOD onlay covering the lingual cusp; Group D: teeth prepared for MOD covering buccal and lingual cusps ,the previous three groups indirectly restored with nanohybrid composite (3M ESPE Z 250 X
... Show Moreيتعرض قانون الموازنة العامة الاتحادية للطعن بعدم الدستورية كغيره من القوانين، بل أن الطعن فيه يكاد يكون سنوياً حال نشره في الجريدة الرسمية ، وتوجه إليه المطاعن بعدم الدستورية إما عن إجراءات تشريعه أو لمضامينه المتعارضة مع الدستور نصاً أو روحاً ، ولكنّه إذا كانت مدة الطعن بعدم دستورية القوانين كافة متاحة دون قيد زمني محدد ولا تتطلب سوى إجراءات إقامة الدعوى العامة وأخصها قيام شرط المصلحة في حالة الدعوى ال
... Show MoreFour samples of the Se55S20Sb15Sn10 alloy were prepared using the melting point method. Samples B, C and D were irradiated with (6.04×1010, 12.08×1010 and 18.12×1010 (n.cm-2s -1 ) of thermal neutron beam from a neutron source (241Am-9Be) respectively, while sample A was left not irradiated. The electrical properties were assessed both before and after the radiation. All irradiated and non-irradiated samples show three conduction mechanisms, at low temperatures, electrical conductivity is achieved by electron hopping between local states near the Fermi level. At intermediate temperatures, conduction occurs by the jumping of electrons between local states at band tails. At high temperatures, electrons transfer between extended stat
... Show MoreBackground: In dentistry, dentist takes the advantages of soft lining materials due to the viscoelastic properties. The major problem is the adhesion of the soft liner with the denture base material. Materials and Methods: Heat cured of high impact acrylic resin specimens prepared with dimensions 75x13x13mm for shear bond strength test, soft lining material (Refit and Mollosil) with a 3-mm thickness and used to join each two acrylic blocks. Also four specimens with the same previous dimensions utilized for chemical and physical surface analysis. The specimens grouped as control (without plasma) and experiment (with oxygen plasma) treated high impact acrylic specimens. Results: Plasma treatment increased the shear bond strength for both Refi
... Show MoreIncreased attention to corporate governance with the increasing need for investors and other parties in the Iraqi market for securities of the information credible and confidence and greater transparency in the disclosure as well as the systems of governance lead to raise the value of the company and that by reducing the cost of capital and reduce the cost of financing, as well as that there are indications modern measurement can be adopted by the Iraqi market for securities for the purpose of evaluating the performance of listed companies and then raise their value.
The research problem is that there is no framework or structure of the legal and local rules for the application of corporate governance in Iraq obliges
... Show More