Background: Speckle tracking echocardiography (STE)-derived mitral annular displacement (MAD) utilizes the speckle tracking technique to measure strain vectors, which provides accurate estimates of left ventricular ejection fraction (LVEF).Objectives: To validate the accuracy of mitral annular displacement (MAD), assessed by Speckle Tracking Echocardiography (STE), as a surrogate for determination of left ventricular systolic function in comparison to 2-Dimensions Simpson method in patients with different heart diseases.Methods : This cross-sectional study included patients who referred to outpatient department of Ibn Albitar Center for Cardiac Surgery, Baghdad, Iraq, between October 2012 and April 2013. STE continuously tracked annular motion throughout the cardiac cycle in the apical 4- and 2-chamber views. LVEF for each patient was measured by both Simpson method and STE-derived MAD.Results: This study included 100 patients, of them (35%) had ischemic heart disease (IHD), (10%) had dilated cardiomyopathy (DCM), (10%) had valvular heart disease (VHD), (25%) had normal echocardiography, and (20%) had hypertensive heart disease (HHD).There was significant correlation between EF % (derived by MAD) and EF % (derived by Simpson method) in patients with different heart diseases. This correlation was good in normal subjects (r=0.673), and those with IHD(r=0.896), DCM (r=0.724) and VHD (r=0.935), while in HHD it was moderately correlated (r=0.455). There was slight under-estimation of LVEF derived by MAD (a mean value of difference 0.846 %; p =0.022). In subgroup analysis, this difference was seen only in patients with HHD (a mean value of difference 3.145 %; p <0.001), while it was absent in other subgroups.Conclusion: STE-derived MAD provides easy, fast, and accurate assessments of global longitudinal systolic function. LVEF derived by MAD was correlated well with LVEF derived by Simpson method in patients with different heart diseases
Functionalized-multi wall carbon nanotubes (F-MWCNTs) and functionalized-single wall carbon nanotubes (F-SWCNTs) were well enhanced using CoO Nanoparticles. The sensor device consisted of a film of sensitive material (F-MWCNTs/CoONPs) and (F-SWCNTs/CoO NPs) deposited by drop- casting on an n-type porous silicon substrate. The two sensors perform high sensitivity to NO2 gas at room temperatures. The analysis indicated that the (F-MWCNTs/CoONPs) have a better performance than (F-SWCNTs/CoONPs). The F-SWCNTs/CoONPs gas sensor shows high sensitivity (19.1 %) at RT with response time 17 sec, while F-MWCNTs/CoONPs gas sensor show better sensitivity (39 %) at RT with response time 13 sec. The device shows a very reproducible sensor p
... Show MoreIn the last years, a new technology called Cloud computing has been developed. Empirical and previous studies, commonly examined in business field and other domains. In this study, the significant factors that affecting the adoption of cloud computing have been examined using a frequency analysis that have been explored by the previous studies. The results showed that the most effected factors were relative advantage which followed by security and privacy, complexity, innovativeness, and external support. In this study the model of technology organization-environment was used to examine the significant factors that affecting the adoption of cloud computing.
Two samples of (Ag NPs-zeolite) nanocomposite thin films have been prepared by easy hydrothermal method for 4 hours and 8 hours inside the hydrothermal autoclave at temperatures of 100°C. The two samples were used in a photoelectrochemical cell as a photocatalyst inside a cell consisting of three electrodes: the working electrode photoanode (AgNPs-zeolite), platinum as a cathode electrode, and Ag/AgCl as a reference electrode, to study the performance of AgNPs-zeolite under dark current and 473 nm laser light for water splitting. The results show the high performance of an eight-hour sample with high crystallinity compared with a four-hour sample as a reliable photocatalyst to generate hydrogen for renewable energies.
ABSTRACT Possible interference of vamin nutritional solution with the activity of several B-lactam antibiotics against E.coli was evaluated in vitro.In Minimal basal salts-glucose medium rapid growth inhibition of sensitive E. coli was induced by 4 µg/ml of ampicillin / cloxaillin, 8 µg/ml of ampicillin, 6 µg/ml of carbencillin, hostacillin, and cephalotin, and by 32 µg/ml of penicillin G and cloxacillin. Significant inactivation of up to 32 µg/ml of carbencillin, cephalotin, penicillin G, and hostacillin was induced by addition of 1:20 v/v vamin. This inactivation was due to the presence of specific amino acids in the mixture. Deletions of amino acids revealed that valine, leucine, isoleucine, tyrosine, tryptophan, phenylalanine, cys
... Show MoreKE Sharquie, AA Noaimi, AG Al-Ghazzi, 2010 - Cited by 2
