Preferred Language
Articles
/
jkmc-359
Basilic Vein Mobilization for Brachio-Basilic Arterio-Venous Fistula in Dialysis
...Show More Authors

Background: The first and second choice for vascular access in patients with end stage renal disease (ESRD) is radio cephalic and brachio cephalic arteriovenous fistula (AVF).In patients with failed previous AVF e or poorly visualized or impalpable cephalic veins, the basilic vein can be mobilized and superficialized to create an AVF with the brachial artery.Objective: The aim of this study is to report our experience at the Vascular Surgery Department/ Surgical Specialty Hospital in brachio-basilic (BB) vascular access for hemodialysis.Methods: From January 2006 to December 2009, 31 patients with ESRD whose cephalic veins were thrombosed or impalpable or had previous unsuccessful vascular access procedures were referred to the Vascular Surgery Department/Surgical Specialty Hospital for creation of vascular access. Brachio - basilic mobilization AVF was offered to them. There were 20 females and 11 males. Their ages ranged from 12 to 70 years with a mean of 40. following a careful clinical assessment of the patients, particularly their upper limb superficial veins, Doppler study of both subclavian veins was done to all patients; those with a vein stenosis exceeding 40% were excluded from the study. All patients had mobilization of basilic vein under general anesthesia via a hooky racket incision on medial aspect of upper arm extending from the axilla to the antecubital fossa. The vein is tunneled subcutaneously and anastomosed end to side to brachial artery. The postoperative condition was monitored looking for any complication. The follow up period lasted for 6 months.Results: nineteen patients (61.3%) had left-sided operations. All fistulae except one functioned well primarily (a success rate of 96.8%). One patient had primary thrombosis of the fistula while another patient developed an aneurysm of the AVF 4 months after the operation. The remainder had a smooth non-complicated postoperative course. All fistulae matured and were ready for cannulation in 6 weeks and remained functioning during the 6 months of follow up.Conclusion:: Brachio-basilic AV fistula with anterior basilica vein mobilization is an acceptable option for dialysis with good success rate and fewer complications

View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Nov 05 2021
Journal Name
Semiconductor Science And Information Devices
Cladding Modified Fiber Bragg Grating for Copper Ions Detection
...Show More Authors

This paper reports a fiber Bragg grating (FBG) as a biosensor. The FBGs were etched using a chemical agent,namely,hydrofluoric acid (HF). This implies the removal of some part of the cladding layer. Consequently, the evanescent field propagating out of the core will be closer to the environment and become more sensitive to the change in the surrounding. The proposed FBG sensor was utilized to detect toxic heavy metal ions aqueous medium namely, copper ions (Cu2+). Two FBG sensors were etched with 20 and 40 μm diameters and fabricated. The sensors were studied towards Cu2+ with different concentrations using wavelength shift as a result of the interaction between the evanescent field and copper ions. The FBG sensors showed

... Show More
View Publication
Crossref (1)
Crossref
Publication Date
Sun Aug 15 2021
Journal Name
Al-qadisiyah Journal Of Pure Science Vol.(26) Issue (special Issue Num.4) (2021) Pp. 27–30
Cyclic partition for the groups of (2,41) and (2,43)
...Show More Authors

Publication Date
Wed Jul 06 2022
Journal Name
Journal Of Al-qadisiyah For Computer Science And Mathematics
Pixel Based Techniques for Gray Image Compression: A review
...Show More Authors

Currently, with the huge increase in modern communication and network applications, the speed of transformation and storing data in compact forms are pressing issues. Daily an enormous amount of images are stored and shared among people every moment, especially in the social media realm, but unfortunately, even with these marvelous applications, the limited size of sent data is still the main restriction's, where essentially all these applications utilized the well-known Joint Photographic Experts Group (JPEG) standard techniques, in the same way, the need for construction of universally accepted standard compression systems urgently required to play a key role in the immense revolution. This review is concerned with Different

... Show More
View Publication
Crossref (1)
Crossref
Publication Date
Sun Jun 07 2015
Journal Name
Baghdad Science Journal
Potential Energy Expectation Value for Lithium Excited State (1s2s3s)
...Show More Authors

The purpose of the present work is to calculate the expectation value of potential energy for different spin states (??? ? ???,??? ? ???) and compared it with spin states (??? , ??? ) for lithium excited state (1s2s3s) and Li- like ions (Be+,B+2) using Hartree-Fock wave function by partitioning techanique .The result of inter particle expectation value shows linear behaviour with atomic number and for each atom and ion the shows the trend ??? < ??? < ??? < ???

View Publication Preview PDF
Crossref
Publication Date
Tue Jul 30 2024
Journal Name
Academia Open
Positioning Preterm Newborns for Cardiorespiratory Stability A Global Insight
...Show More Authors

Publication Date
Tue Oct 01 2013
Journal Name
2013 Ieee International Conference On Systems, Man, And Cybernetics
AWSS: An Algorithm for Measuring Arabic Word Semantic Similarity
...Show More Authors

View Publication
Scopus (24)
Crossref (12)
Scopus Clarivate Crossref
Publication Date
Sun Jan 01 2017
Journal Name
Proceedings Of The Conference “recent Trends In Engineering Sciences And Sustainability”, Baghdad
GNSS positioning techniques for enhancing Google Earth data quality
...Show More Authors

Due to the easily access to the satellite images, Google Earth (GE) images have become more popular than other online virtual globes. However, the popularity of GE is not an indication of its accuracy. A considerable amount of literature has been published on evaluating the positional accuracy of GE data; however there are few studies which have investigated the subject of improving the GE accuracy. In this paper, a practical method for enhancing the horizontal positional accuracy of GE is suggested by establishing ten reference points, in University of Baghdad main campus, using different Global Navigation Satellite System (GNSS) observation techniques: Rapid Static, Post-Processing Kinematic, and Network. Then, the GE image for the study

... Show More
Publication Date
Tue Dec 01 2015
Journal Name
2015 9th Malaysian Software Engineering Conference (mysec)
Factors for communication technologies selection within virtual software teams
...Show More Authors

View Publication
Scopus (2)
Scopus Crossref
Publication Date
Sat Oct 01 2022
Journal Name
Iraqi Postgraduate Medical Journal
Helicobacter Pylori Infection among Dyspeptic Patients Referred for Endoscopy
...Show More Authors

Functional dyspepsia is one of the most common gastrointestinal symptoms and attributed to various causes including Helicobacter pylori infection. AIM OF THE STUDY: To correlate Helicobacter pylori infection to functional dyspepsia and to identify the possible risk factors for this infection. PATIENTS AND METHODS: Fifty patients who were referred to the endoscopy unit for dyspepsia symptoms, secondary gastric causes of dyspepsia were excluded during endoscopy, gastric biopsies were taken for histopathological study and for bedside urease test for detection of Helicobacter pylori infection. RESULTS: 62% of non-ulcer dyspeptic patients were infected with Helicobacter pylori, 74.2% of the patients were above 30 years old, female gender patient

... Show More
Publication Date
Thu Sep 15 2022
Journal Name
Romanian Neurosurgery
Coil migration during pressure-cooker technique for cerebral AVM
...Show More Authors

Introduction: In recent decades, the endovascular treatment of cerebral arteriovenous malformations (AVMs) has advanced. However, it still carries risks of unanticipated complications. Coil migration is a reported complication of aneurysmal coiling procedures. Herein, we report a case of early intraprocedural coil migration during pressure cooker technique embolization of right thalamic AVM, discussing the management and potential explanations. The literature showed no report of coil migration after the pressure cooker technique in the form of coil-augmented Onyx injection technique (CAIT). Case description: An otherwise healthy 26-year-old female suddenly developed a severe headache with no loss of consciousness. Computed tomograp

... Show More
View Publication Preview PDF
Crossref (2)
Crossref