Background: The first and second choice for vascular access in patients with end stage renal disease (ESRD) is radio cephalic and brachio cephalic arteriovenous fistula (AVF).In patients with failed previous AVF e or poorly visualized or impalpable cephalic veins, the basilic vein can be mobilized and superficialized to create an AVF with the brachial artery.Objective: The aim of this study is to report our experience at the Vascular Surgery Department/ Surgical Specialty Hospital in brachio-basilic (BB) vascular access for hemodialysis.Methods: From January 2006 to December 2009, 31 patients with ESRD whose cephalic veins were thrombosed or impalpable or had previous unsuccessful vascular access procedures were referred to the Vascular Surgery Department/Surgical Specialty Hospital for creation of vascular access. Brachio - basilic mobilization AVF was offered to them. There were 20 females and 11 males. Their ages ranged from 12 to 70 years with a mean of 40. following a careful clinical assessment of the patients, particularly their upper limb superficial veins, Doppler study of both subclavian veins was done to all patients; those with a vein stenosis exceeding 40% were excluded from the study. All patients had mobilization of basilic vein under general anesthesia via a hooky racket incision on medial aspect of upper arm extending from the axilla to the antecubital fossa. The vein is tunneled subcutaneously and anastomosed end to side to brachial artery. The postoperative condition was monitored looking for any complication. The follow up period lasted for 6 months.Results: nineteen patients (61.3%) had left-sided operations. All fistulae except one functioned well primarily (a success rate of 96.8%). One patient had primary thrombosis of the fistula while another patient developed an aneurysm of the AVF 4 months after the operation. The remainder had a smooth non-complicated postoperative course. All fistulae matured and were ready for cannulation in 6 weeks and remained functioning during the 6 months of follow up.Conclusion:: Brachio-basilic AV fistula with anterior basilica vein mobilization is an acceptable option for dialysis with good success rate and fewer complications
A simple analytical method was used in the present work for the simultaneous quantification of Ciprofloxacin and Isoniazid in pharmaceutical preparations. UV-Visible spectrophotometry has been applied to quantify these compounds in pure and mixture solutions using the first-order derivative method. The method depends on the first derivative spectrophotometry using zero-cross, peak to baseline, peak to peak and peak area measurements. Good linearity was shown in the concentration range of 2 to 24 µg∙mL-1 for Ciprofloxacin and 2 to 22 µg∙mL-1 for Isoniazid in the mixture, and the correlation coefficients were 0.9990 and 0.9989 respectively using peak area mode. The limits of detection (LOD) and limits of quantification (LOQ) were
... Show MoreWireless sensor applications are susceptible to energy constraints. Most of the energy is consumed in communication between wireless nodes. Clustering and data aggregation are the two widely used strategies for reducing energy usage and increasing the lifetime of wireless sensor networks. In target tracking applications, large amount of redundant data is produced regularly. Hence, deployment of effective data aggregation schemes is vital to eliminate data redundancy. This work aims to conduct a comparative study of various research approaches that employ clustering techniques for efficiently aggregating data in target tracking applications as selection of an appropriate clustering algorithm may reflect positive results in the data aggregati
... Show MoreIs the chemical industries of great importance for the economy of any country, through what is borne by these industries is an important part of the changes contained in the industrial output of transfer and, moreover, that these industries are overlaps and intricacies of sector-wide with the rest of the manufacturing sectors, with agriculture and services , through the offering of these industries produce Production requirements intervention such as chemical fertilizer used in the production of agricultural crops, in addition to the various areas for the use of phosphorus in the food industry, to the extent that it is difficult to find material Food preparation is not included i
... Show MoreThe catalytic wet air oxidation (CWAO) of phenol has been studied in a trickle bed reactor
using active carbon prepared from date stones as catalyst by ferric and zinc chloride activation (FAC and ZAC). The activated carbons were characterized by measuring their surface area and adsorption capacity besides conventional properties, and then checked for CWAO using a trickle bed reactor operating at different conditions (i.e. pH, gas flow rate, LHSV, temperature and oxygen partial pressure). The results showed that the active carbon (FAC and ZAC), without any active metal supported, gives the highest phenol conversion. The reaction network proposed account
... Show MoreIn this study water-soluble N-Acetyl Cysteine Capped-Cadmium Telluride QDs (NAC/CdTe nanocrystals) using N-acetyl cysteine as a stabilizer were prepared to investigate the utility of quantum dots (QDs) in distinguishing damaged DNA, (extracted from blood samples of leukaemia patients), from intact DNA (extracted from blood samples of healthy individuals) to be used for biosensing application. Based on the optical characterization of the prepared QDs, the XRD results revealed the formation of the NAC-CdTe-QDs with a grain size of 7.1nm. Whereas, the SEM test showed that the spherical size of the NAC-CdTe-QDs lies within 11~33nm. NAC-CdTe-QDs have superior PL emission properties at of 550nm and UV-Vis absorption peak at 300nm. The energy gap
... Show MoreThe main objective of this paper is to develop and validate flow injection method, a precise, accurate, simple, economic, low cost and specific turbidimetric method for the quantitative determination of mebeverine hydrochloride (MbH) in pharmaceutical preparations. A homemade NAG Dual & Solo (0-180º) analyser which contains two identical detections units (cell 1 and 2) was applied for turbidity measurements. The developed method was optimized for different chemical and physical parameters such as perception reagent concentrations, aqueous salts solutions, flow rate, the intensity of the sources light, sample volume, mixing coil and purge time. The correlation coefficients (r) of the developed method were 0.9980 and 0.9986 for
... Show More