Preferred Language
Articles
/
jkmc-350
Detection of Thrombi in Left Atrial chamber by Transoesophageal Ecchocardiography in patients suffer from Non-rheumatic Atrial Fibrillation
...Show More Authors

Background: Background : Patients with non-rheumatic atrial fibrillation have high risk of thromboembolism especially ischemic stroke usually arising from left atrial appendage .Transoesophageal echocardiography provides useful information for risk stratification in these patients as it detects thrombus in the left atrial or left atrial appendage. Objective : This study was conducted at Al-Kadhimiya Teaching Hospital to assess the prevalence of left atrial chamber thrombi in patients with chronic non-rheumatic atrial fibrillation using transoesophageal echocardiography and its clinical significance as well as to verify the superiority of transoesophageal over transthoracic echocardiography in the detection of these abnormalities. Type of the study: Cross sectional study.Patients and Methods : Forty (40) consecutive patients (11 female and 29 male), at a mean age of 46 ± 9 years (range 28–60) with chronic non-rheumatic Atrial fibrillation were enrolled to this prospective study between March 2006 and December 2006. Tansthoracic and transesophageal two dimensional , M- mode , Doppler, and color- flow echocardiography were obtained with a kretz diagnostic ultrasound system. Results : The prevalence of Left atrium thrombus was 12.5%, 5 patients from the total number which was 40 patients. All of them seen bytransoesophagealechocardiography and non are detected byTansthoracic echocardiography . All the left atrial thrombi were confined to the left atrial appendage (100%). Left atrial spontaneous echo contrast was detected in 10 patients 25% by transoesophageal echocardiography, but was not observed in patient bytransthoracic echocardiography. All the 5 thrombi were found in left atria were significantly associated with spontaneous echo contrast 100% (P-value <0.001), reduced left ventricle ejection fraction (p-value <0.05) , large left atrium diameter ( p-value <0.05) and low LAAV <20 cm/s (p-value <0.001) compared to those without thrombus . Conclusions : The study showed that the prevalence of left atrial thrombus and appendage is not uncommon in patients with non-rheumatic atrial fibrillation and is exclusively seen in patients with left atrial SEC. Low Left ventricle ejection fraction , large Left atrium diameter , and low Left atrial appendages velocity are significantly associated with subsequent thrombus formation , and is more sensitive in the detection of these abnormalities compared with transthoracic echocardiography

View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Jan 20 2026
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Comparative Histopathological Study of Ciprofloxacin Impact on Mus Musculus Renal Cortex Infected with Multi-drug Resistance and Susceptible Uropathogenic Escherichia Coli
...Show More Authors

Urinary tract infections are mainly caused by uropathogenic Escherichia coli, which represent a significant global issue along with the rising of antibiotic resistance and treatment challenges. The aim of this study was to evaluate ciprofloxacin efficacy as a treatment in animal models following infection with multidrug-resistant UPEC and multidrug-susceptible UPEC and to determine the nephrotoxic effect of these antibiotics on the renal cortex. Up to 76 E. coli isolates were collected from UTI patients in Baghdad province, characterized by morphological and biochemical features, and confirmed using the Vitek-2 compact system. Mice were orally infected via gastric gavage with G33 using a bacterial load of 107 cells/ml, followed by p

... Show More
View Publication
Crossref
Publication Date
Sat Jan 01 2022
Journal Name
International Journal Of Applied Science And Engineering
The effect of model scale, acceleration history, and soil condition on closed-ended pipe pile response under coupled static-dynamic loads
...Show More Authors

This paper analyzes the effect of scaling-up model and acceleration history on seismic response of closed-ended pipe pile using a finite element modeling approach and the findings of 1 g shaking table tests of a pile embedded in dry and saturated soils. A number of scaling laws were used to create the numerical modeling according to the data obtained from 1 g shake table tests performed in the laboratory. The current study found that the behaviors of the scaled models, in general have similar trends. From numerical modeling on both the dry and saturated sands, the normalized lateral displacement, bending moment, and vertical displacement of piles with scale factors of 2 and 35 are less than those of the pile with a scale factor of 1 and the

... Show More
Scopus (17)
Crossref (11)
Scopus Crossref
Publication Date
Sun Sep 13 2026
Journal Name
Journal Of Pharmaceutical Health Care And Sciences
Evaluating public acceptance of the official medicine label and mobile verification application: a mixed-methods study applying the technology acceptance model
...Show More Authors
Abstract<sec> <title>Background

The Iraqi pharmaceutical sector faces significant challenges arising from the prevalence of substandard and falsified (S/F) medications, which pose a direct threat to public health safety. To strengthen regulatory oversight, health authorities have implemented national medicine track-and-trace system. However, the ultimate efficacy of these regulatory tools is heavily dependent on public awareness and the level of societal acceptance.

Objective

This study ai

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Jun 01 2026
Journal Name
Ecological Engineering &amp; Environmental Technology
Towards low-energy desalination: Performance analysis and design of single and two-stage reverse osmosis systems to minimize specific energy consumption
...Show More Authors

Lowering specific energy consumption (SEC) in reverse osmosis (RO) plants is one of the most important criteria in water treatment industry. The present work focused on best suggested RO pilot plant configurations for minimizing specific energy consumption, finding the best configurations experimentally to recover the water with minimizing salts in permeate side in RO module, study the factors affecting the performance of single and two stage systems, TFC membrane is used in spiral wound module. Brackish water is used as feed solution with different concentrations (2000, 3000, 4000 and 5000 ppm). The operating parameters studied were permeate flux, rejection and SEC. The experimental results showed the permeate concentration increased and w

... Show More
View Publication
Crossref
Publication Date
Wed Jan 01 2025
Journal Name
Journal Of Power Sources
Impact of tetracyanoethylene plasticizer on PEO based solid polymer electrolytes for improved ionic conductivity and solid-state lithium-ion battery performance
...Show More Authors

Poly(ethylene oxide) is a promising material for solid-state lithium batteries due to its safety, ease of processing, and compatibility with lithium. However, conventional linear PEO falls short of practical requirements due to its limited ionic conductivity, a consequence of the high crystallinity of its ethylene oxide chains. This crystallinity hinders the movement of lithium ions, limiting its performance in solid-state battery applications. In this study, we successfully prepared the plasticized solid polymer electrolytes (PSPEs) based on poly(ethylene oxide) (PEO)/ tetracyanoethylene (TCE) complexed with lithium bis(trifluoromethanesulfonyl)imide (LiTFSI) salt and studied the effect of TCE on structural, mechanical, electrical and elec

... Show More
View Publication
Scopus (64)
Crossref (63)
Scopus Crossref
Publication Date
Sun Dec 01 2024
Journal Name
Energy Storage
Comprehensive Study of PAN-NaBF4 Solid Polymer Electrolytes: Insights Into Optical, Structural, Thermal, Electrical, and Electrochemical Properties for Sodium-Ion Batteries
...Show More Authors

This research explores the use of solid polymer electrolytes (SPEs) as a conductive medium for sodium ions in sodium‐ion batteries, presenting a possible alternative to traditional lithium‐ion battery technology. The researchers prepare SPEs with varying molecular weight ratios of polyacrylonitrile (PAN) and sodium tetrafluoroborate (NaBF4) using a solution casting method with dimethyl formamide as the solvent. Through optical absorbance measurements, we identified the PAN:NaBF4 (80:20) SPE composition as having the lowest energy band gap value (4.48 eV). This composition also exhibits high thermal stability based on thermogravimetric analysis results. Electrochemical impedance spectroscopy re

... Show More
View Publication
Scopus (10)
Scopus
Publication Date
Sat Apr 04 2026
Journal Name
Engineering, Technology &amp; Applied Science Research
Experimental Optimization of PLC-Integrated Multi-Loop PID Control for a Three-Level Electro-Hydraulic Elevator Using PSO and Cheetah Optimizer
...Show More Authors

This study presents the design, modeling, and experimental evaluation of a three-level electro-hydraulic elevator system controlled by a Delta DVP-20SX2 Programmable Logic Controller (PLC) equipped with an integrated Proportional–Integral–Derivative (PID) module. The PLC, programmed in Ladder Logic using ISPSoft 2.46, regulates cabin motion across all three levels. A detailed MATLAB/Simulink model was developed, incorporating three PID controllers: one for displacement regulation via a proportional directional control valve and two for dynamic pressure regulation using a proportional pressure relief valve. Conventional PID parameters were initially tuned using the trial-and-error method based on time-domain performance indices a

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Wed Sep 08 2021
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
Strategic tax planning and its impact on reducing tax evasion
...Show More Authors

Taxes are an essential axis in the economy as the most effective and effective economic tool in any country (economy). Expanding the scope of taxation without adequate study has produced a dangerous result with a negative impact that is almost apparent, namely (tax evasion), which stands as a barrier preventing the state from reaching Therefore, the research sought to study strategic tax planning and its importance in reducing tax evasion, and the research aims from that to prove the importance of adopting strategic planning in the field of taxes according to modern and effective scientific foundations to reduce tax evasion to enhance the achievement of tax evasion. The financing objective is in addition to the other objectives,

... Show More
View Publication Preview PDF
Publication Date
Mon Dec 31 2018
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
BIOLOGICAL ASPECTS AND PREDATORY EFFICIENY OF PREDATOR Chilocorus bipustulatus (L.) COLEOPTERA :COCCINELLIDAE ON DATE PALM SCALE Parlatoria blanchardi (T.) DIASPIDIDAE: HOMOPTERA UNDER LABORATORY CONDITIONS.: BIOLOGICAL ASPECTS AND PREDATORY EFFICIENY OF PREDATOR Chilocorus bipustulatus (L.) COLEOPTERA :COCCINELLIDAE ON DATE PALM SCALE Parlatoria blanchardi (T.) DIASPIDIDAE: HOMOPTERA UNDER LABORATORY CONDITIONS.
...Show More Authors

Laboratory studies were conducted at the biological control unit, college of Agriculture, University of Baghdad to evaluate some biological aspects of the predator Chilocorus bipustulatus (Coleoptera: Coccinellidae), which is considered one of the most important predators on many insect pests, especially the scale insect, Parlatoria blanchardi, (Homoptera: Diaspididae) on date palms. The results showed that biological parameters of the predator were varied according to different degree of temperature. Egg incubation period was significantly different and reached to 7.5 and 5.44 day at 25 and 30°C respectively, Fertility was the same 100% at both temperature degrees. Larval growth periods were 17.41 and 16.12 day as well as the mortality

... Show More
View Publication Preview PDF
Publication Date
Wed Jan 01 2014
Journal Name
Iraqi Journal Of Science
Calculate the Longitude and Orbital Motion for Amaletha, Europa, Ganymede and Callisto Satellites
...Show More Authors

The orbital motion and longitude for some Jupiter's satellites (Amaletha, Europa, Ganymede and Callisto) were calculated from two different locations Iraq and Syria. A program was designed, the input parameters were the desired year, month, day and the longitude of the location, the output parameters results were applied in form of a file, and this file includes the longitude, orbital motion, and local time of these satellites. A specific date 1-10-2013 was taken, the results of longitude was (20-336) º and orbital motion was (92-331) º for both Iraq and Syria location with observing time (05:24:14-15:18:10) for Iraq and (04:56:33-14:50:30) for Syria. The difference in time between the two locations was constant (00:45:00), these results

... Show More