Background: Background : Patients with non-rheumatic atrial fibrillation have high risk of thromboembolism especially ischemic stroke usually arising from left atrial appendage .Transoesophageal echocardiography provides useful information for risk stratification in these patients as it detects thrombus in the left atrial or left atrial appendage. Objective : This study was conducted at Al-Kadhimiya Teaching Hospital to assess the prevalence of left atrial chamber thrombi in patients with chronic non-rheumatic atrial fibrillation using transoesophageal echocardiography and its clinical significance as well as to verify the superiority of transoesophageal over transthoracic echocardiography in the detection of these abnormalities. Type of the study: Cross sectional study.Patients and Methods : Forty (40) consecutive patients (11 female and 29 male), at a mean age of 46 ± 9 years (range 28–60) with chronic non-rheumatic Atrial fibrillation were enrolled to this prospective study between March 2006 and December 2006. Tansthoracic and transesophageal two dimensional , M- mode , Doppler, and color- flow echocardiography were obtained with a kretz diagnostic ultrasound system. Results : The prevalence of Left atrium thrombus was 12.5%, 5 patients from the total number which was 40 patients. All of them seen bytransoesophagealechocardiography and non are detected byTansthoracic echocardiography . All the left atrial thrombi were confined to the left atrial appendage (100%). Left atrial spontaneous echo contrast was detected in 10 patients 25% by transoesophageal echocardiography, but was not observed in patient bytransthoracic echocardiography. All the 5 thrombi were found in left atria were significantly associated with spontaneous echo contrast 100% (P-value <0.001), reduced left ventricle ejection fraction (p-value <0.05) , large left atrium diameter ( p-value <0.05) and low LAAV <20 cm/s (p-value <0.001) compared to those without thrombus . Conclusions : The study showed that the prevalence of left atrial thrombus and appendage is not uncommon in patients with non-rheumatic atrial fibrillation and is exclusively seen in patients with left atrial SEC. Low Left ventricle ejection fraction , large Left atrium diameter , and low Left atrial appendages velocity are significantly associated with subsequent thrombus formation , and is more sensitive in the detection of these abnormalities compared with transthoracic echocardiography
In this research note approximately prime submodules is defined as a new generalization of prime submodules of unitary modules over a commutative ring with identity. A proper submodule of an -module is called an approximaitly prime submodule of (for short app-prime submodule), if when ever , where , , implies that either or . So, an ideal of a ring is called app-prime ideal of if is an app-prime submodule of -module . Several basic properties, characterizations and examples of approximaitly prime submodules were given. Furthermore, the definition of approximaitly prime radical of submodules of modules were introduced, and some of it is properties were established.
n this study, data or X-ray images Fixable Image Transport System (FITS) of objects were analyzed, where energy was collected from the body by several sensors; each sensor receives energy within a specific range, and when energy was collected from all sensors, the image was formed carrying information about that body. The images can be transferred and stored easily. The images were analyzed using the DS9 program to obtain a spectrum for each object,an energy corresponding to the photons collected per second. This study analyzed images for two types of objects (globular and open clusters). The results showed that the five open star clusters contain roughly t
... Show Moreيهدف البحث الحالي إلى اختبار العلاقة بين نوعية حياة العمل والإبداع التنظيمي في ديوان وزارة التخطيط ، ولبلوغ الهدف المذكور وبناء على معطيات البحث الاستطلاعي للباحث بني ألانموذج الفرضي للبحث الذي ضم المتغير المستقل والمعتمد، واعتماداً على حركية الأنموذج صيغت فرضيتان، ولاختبار صحة الفرضيات وجمع المعلومات من عينة البحث البالغة (100) مدير يمثلون مرك
... Show MoreIn the process of translating Qur’anic texts, there is an urgent need for interpretations of the Qur’anic text due to the presence of many incomprehensible Qur’anic verses or words because of our distance from the standard Arabic, language in which the Holy Qur’an was revealed, and the introduction of the foreign words into our language, in addition to the fact that many Qur’anic words are no longer used. All this prompted the need for the interpretation of the Qur'anic text, Therefore, it is necessary for the translator to resort to the books of interpretation if he intends to translate the Qur’an
This research deals with the rhetoric purposes of the passive voice in the holy Quran. First, we put an introductory to the concept of the Quran language and its difference of the spoken Arabic language during the revelation period. Besides; we gave a brief about the structure passive voice form of Arabic language. Second, we explained the purposes of passive voice used in the holly Quran with sufficient examples, commentaries and clarifications about all the cases. Rhetoric purposes that we deals with are: concision, emphasize an idea, avoid using the subject because it is known and clear for all or because it is really unknown, etc. This part has contained the most important purposes for the use of passive voice in holy Quran. At the end
... Show MoreMaintaining and breeding fish in a pond are a crucial task for a large fish breeder. The main issues for fish breeders are pond management such as the production of food for fishes and to maintain the pond water quality. The dynamic or technological system for breeders has been invented and becomes important to get maximum profit return for aquaponic breeders in maintaining fishes. This research presents a developed prototype of a dynamic fish feeder based on fish existence. The dynamic fish feeder is programmed to feed where sensors detected the fish's existence. A microcontroller board NodeMCU ESP8266 is programmed for the developed h
... Show MorePalm vein recognition is a one of the most efficient biometric technologies, each individual can be identified through its veins unique characteristics, palm vein acquisition techniques is either contact based or contactless based, as the individual's hand contact or not the peg of the palm imaging device, the needs a contactless palm vein system in modern applications rise tow problems, the pose variations (rotation, scaling and translation transformations) since the imaging device cannot aligned correctly with the surface of the palm, and a delay of matching process especially for large systems, trying to solve these problems. This paper proposed a pose invariant identification system for contactless palm vein which include three main
... Show MoreEight different Dichloro(bis{2-[1-(4-R-phenyl)-1H-1,2,3-triazol-4-yl-κN3]pyridine-κN})iron(II) compounds, 2–9, have been synthesised and characterised, where group R=CH3 (L2), OCH3 (L3), COOH (L4), F (L5), Cl (L6), CN (L7), H (L8) and CF3 (L9). The single crystal X-ray structure was determined for the L3 which was complemented with Density Functional Theory calculations for all complexes. The structure exhibits a distorted octahedral geometry, with the two triazole ligands coordinated to the iron centre positioned in the equatorial plane and the two chloro atoms in the axial positions. The values of the FeII/III redox couple, observed at ca. −0.3 V versus Fc/ Fc+ for complexes 2–9, varied over a very small potential range of 0.05 V.
... Show MoreThe eaction of 2 4 .6-trihydroxyactophenonemonohydra1e with
l hydr.azine monohydrate was realized ti·nder reflu.(( in methanol and i:l.
Jew drops of glacial acetic acid we.re added to give lhe'(int rmediate)
2-(1hydr pno-ctbyt)-benzcne-·1.3.5-r:Qql, which reacted wittl
saEcy.laldehyde. jn methm)ql to gjy;e 'a new :tyRe CNzOi) Ligand (H:flL]
f(2-{1-[(2-=bydroxy-bertzylide·ne)-bydrazqoo,J-e·thy.1}bcnze·neJ ;3·,5
|