Background: Background : Patients with non-rheumatic atrial fibrillation have high risk of thromboembolism especially ischemic stroke usually arising from left atrial appendage .Transoesophageal echocardiography provides useful information for risk stratification in these patients as it detects thrombus in the left atrial or left atrial appendage. Objective : This study was conducted at Al-Kadhimiya Teaching Hospital to assess the prevalence of left atrial chamber thrombi in patients with chronic non-rheumatic atrial fibrillation using transoesophageal echocardiography and its clinical significance as well as to verify the superiority of transoesophageal over transthoracic echocardiography in the detection of these abnormalities. Type of the study: Cross sectional study.Patients and Methods : Forty (40) consecutive patients (11 female and 29 male), at a mean age of 46 ± 9 years (range 28–60) with chronic non-rheumatic Atrial fibrillation were enrolled to this prospective study between March 2006 and December 2006. Tansthoracic and transesophageal two dimensional , M- mode , Doppler, and color- flow echocardiography were obtained with a kretz diagnostic ultrasound system. Results : The prevalence of Left atrium thrombus was 12.5%, 5 patients from the total number which was 40 patients. All of them seen bytransoesophagealechocardiography and non are detected byTansthoracic echocardiography . All the left atrial thrombi were confined to the left atrial appendage (100%). Left atrial spontaneous echo contrast was detected in 10 patients 25% by transoesophageal echocardiography, but was not observed in patient bytransthoracic echocardiography. All the 5 thrombi were found in left atria were significantly associated with spontaneous echo contrast 100% (P-value <0.001), reduced left ventricle ejection fraction (p-value <0.05) , large left atrium diameter ( p-value <0.05) and low LAAV <20 cm/s (p-value <0.001) compared to those without thrombus . Conclusions : The study showed that the prevalence of left atrial thrombus and appendage is not uncommon in patients with non-rheumatic atrial fibrillation and is exclusively seen in patients with left atrial SEC. Low Left ventricle ejection fraction , large Left atrium diameter , and low Left atrial appendages velocity are significantly associated with subsequent thrombus formation , and is more sensitive in the detection of these abnormalities compared with transthoracic echocardiography
In light of the limited sources of funding suffered by the Iraqi economy, it highlights the importance of enhancing the efficiency of public expenditure, and if the measurement of the efficiency of public expenditure and identify benchmarks first step of promoting efficiency, the adoption of scientific methods of analysis imperative in promoting the efficiency. Under this framework, the focus was on the methodologies used to measure the efficiency of public spending and supply analysis with trying statement strengths and weaknesses, and make use of it in the measurement of the efficiency of public spending in the Iraqi economy. As well as devise measurable indicators take into account the specificity of the Iraqi economy and the
... Show MoreThis work is devoted to study the properties of the ground states such as the root-mean square ( ) proton, charge, neutron and matter radii, nuclear density distributions and elastic electron scattering charge form factors for Carbon Isotopes (9C, 12C, 13C, 15C, 16C, 17C, 19C and 22C). The calculations are based on two approaches; the first is by applying the transformed harmonic-oscillator (THO) wavefunctions in local scale transformation (LST) to all nuclear subshells for only 9C, 12C, 13C and 22C. In the second approach, the 9C, 15C, 16C, 17C and 19C isotopes are studied by dividing the whole nuclear system into two parts; the first is the compact core part and the second is the halo part. The core and halo parts are studied using the
... Show MoreChromatographic and spectrophotometric methods for the estimation of mebendazole in
pharmaceutical products were developed. The flow injection method was based on the oxidation of
mebendazole by a known excess of sodium hypochlorite at pH=9.5. The excess sodium hypochlorite is then
reacted with chloranilic acid (CAA) to bleach out its color. The absorbance of the excess CAA was recorded
at 530 nm. The method is fast, simple, selective, and sensitive. The chromatographic method was carried out
on a Varian C18 column. The mobile phase was a mixture of acetonitrile (ACN), methanol (MeOH), water
and triethylamine (TEA), (56% ACN, 20% MeOH, 23.5% H2O, 0.5% TEA, v/v), adjusted to pH = 3.0 with
1.0 M hy
In this study the faunistic of lady beetles (Coleoptera, Coccinellidae) was studied in Mehriz region (Yazd province) during 2009-2010. The total number of specimens of coccinellid beetles were collected from 6 different localities having altitudes from 1420-2420 m. Altogether 11 species from 8 genera, 3 tribes and 3 subfamilies were collected and identified. External characters plus characteristics male and female genitalia were used in order to diagnose species. Seven species were recorded for the first time from Yazd province (marked*). Many species were predacious, preying on various species of aphids, mites and coccids. Some species were also sent to Dr. Helmut Fursch in Germany for identification or confirmation. T
... Show MoreConstruction is the opening of the important pillars of the construction of the film as a whole for this, we find that the first of any narrative of my film begin at the borders of this construction is the window that we look through the contents tale and puzzle narrative is of significance that degrade traveler when reservoirs expression later in reasoning and find justifications ills that came by those initiation, this initiation may be the window that lead us to the core, understanding the story through signals received to the recipient to sail because of the paths of pickling what is which is encoded, but this initiation may serve as keys that understanding the be puppies and signals that beset and surrounded to what He holds inevita
... Show MoreThe current research aims to identify the level of strategic orientation and its dimensions (vision, mission, goals, and values) in the Iraqi National Security Service (INSS). The researchers followed the descriptive analytical approach as one of the forms of analysis and organized scientific interpretation to describe a specific phenomenon or problem, adopting the form questionnaire being the main source in collecting data and preparing for this. Based on the program of the Statistical Package of Social Sciences (SPSS 26) to analyze the data and come up with the final research results to identify the opinions of the intended sample on the subject of research, and the questionnaire of (20) paragraphs included the search variable, and was
... Show MoreThe effect of superficial gas velocity within the range 0.01-0.164 m/s on gas holdup (overall, riser and down comer), volumetric oxygen mass transfer coefficient, liquid circulation velocity was studied in an internal loop concentric tubes airlift reactor (working volume 45 liters). It was shown that as the usg increases the gas holdup and also the liquid circulation velocity increase. Also it was found that increasing superficial gas velocity lead to increase the interfacial area that increases the overall oxygen mass transfer coefficient. The hydrodynamic experimental results were modeled with the available equations in the literature. The predicted data gave an acceptable accuracy with the empirical data.
The final
... Show MoreBACKGROUND: Preterm labour is a major cause of perinatal morbidity and mortality, so it is important to predict preterm delivery using the clinical examination of the cervix and uterine contraction frequency. New markers for the prediction of preterm birth have been developed such as transvaginal ultrasound measurement of cervical length as this method is widely available. OBJECTIVE: To determine, whether transvaginal cervical length measurement predicts imminent preterm delivery better than digital cervical length measurement in women presented with preterm labour and intact membranes. PATIENTS AND METHODS: Two hundred women presented with preterm labour between 24 and 36+6 weeks of gestation were included in this study. All women subjecte
... Show More