Background: Background : Patients with non-rheumatic atrial fibrillation have high risk of thromboembolism especially ischemic stroke usually arising from left atrial appendage .Transoesophageal echocardiography provides useful information for risk stratification in these patients as it detects thrombus in the left atrial or left atrial appendage. Objective : This study was conducted at Al-Kadhimiya Teaching Hospital to assess the prevalence of left atrial chamber thrombi in patients with chronic non-rheumatic atrial fibrillation using transoesophageal echocardiography and its clinical significance as well as to verify the superiority of transoesophageal over transthoracic echocardiography in the detection of these abnormalities. Type of the study: Cross sectional study.Patients and Methods : Forty (40) consecutive patients (11 female and 29 male), at a mean age of 46 ± 9 years (range 28–60) with chronic non-rheumatic Atrial fibrillation were enrolled to this prospective study between March 2006 and December 2006. Tansthoracic and transesophageal two dimensional , M- mode , Doppler, and color- flow echocardiography were obtained with a kretz diagnostic ultrasound system. Results : The prevalence of Left atrium thrombus was 12.5%, 5 patients from the total number which was 40 patients. All of them seen bytransoesophagealechocardiography and non are detected byTansthoracic echocardiography . All the left atrial thrombi were confined to the left atrial appendage (100%). Left atrial spontaneous echo contrast was detected in 10 patients 25% by transoesophageal echocardiography, but was not observed in patient bytransthoracic echocardiography. All the 5 thrombi were found in left atria were significantly associated with spontaneous echo contrast 100% (P-value <0.001), reduced left ventricle ejection fraction (p-value <0.05) , large left atrium diameter ( p-value <0.05) and low LAAV <20 cm/s (p-value <0.001) compared to those without thrombus . Conclusions : The study showed that the prevalence of left atrial thrombus and appendage is not uncommon in patients with non-rheumatic atrial fibrillation and is exclusively seen in patients with left atrial SEC. Low Left ventricle ejection fraction , large Left atrium diameter , and low Left atrial appendages velocity are significantly associated with subsequent thrombus formation , and is more sensitive in the detection of these abnormalities compared with transthoracic echocardiography
Currently, there is an intensive development of bipedal walking robots. The most known solutions are based on the use of the principles of human gait created in nature during evolution. Modernbipedal robots are also based on the locomotion manners of birds. This review presents the current state of the art of bipedal walking robots based on natural bipedal movements (human and bird) as well as on innovative synthetic solutions. Firstly, an overview of the scientific analysis of human gait is provided as a basis for the design of bipedal robots. The full human gait cycle that consists of two main phases is analysed and the attention is paid to the problem of balance and stability, especially in the single support phase when the biped
... Show MoreGalvanic corrosion of stainless steel 316 (SS316) and carbon steel (CS) coupled in 5% wt/v sulfuric acid solution at agitation velocity was investigated. The galvanic behavior of coupled metals was also studied using zero resistance ammeter (ZRA) method. The effects of agitation velocity, temperature, and time on galvanic corrosion current and loss in weight of both metals in both free corrosion and galvanic corrosion were investigated. The trends of open circuit potential (OCP) of each metal and galvanic potential (Eg) of the couple were, also, determined. Results showed that SS316 was cathodic relative to CS in galvanic couple and its OCP was much more positive than that of CS for all investigated ranges of
... Show MoreThe evacuated tube solar collector ETC is studied intensively and extensively by experimental and
theoretical works, in order to investigate its performance and enhancement of heat transfer, for Baghdad climate
from April 2011 till the end of March 2012. Experimental work is carried out on a well instrumented collector
consists of 16 evacuated tubes of aspect ratio 38.6 and thermally insulated tank of volume 112L. The relation
between convective heat transfer and natural circulation inside the tube is estimated, collector efficiency, effect of
tube tilt angles, incidence angle modifier, The solar heating system is investigated under different loads pattern (i.e
closed and open flow) to evaluate the heat loss coefficient
This study introduces a series of single and pile group model tests subjected to lateral loads in . multilayered sand from Karbala, Iraq. The aim of this study is to investigate: the performance of the pile groups subjected to lateral loads; in which the pile batter inclination angle is changed; the effect of pile spacing (s/d) ratio, the influence of using different number of piles and pile group configuration. Results revealed that the performance of single negative (Reverse) Battered piles with inclination of 10° and 20° show a gain of 32% and 76 % in the ultimate lateral capacity over the regular ones. For pile groups, the use of a combination of regular, negative and positive battered piles in
... Show MoreGenerally, direct measurement of soil compression index (Cc) is expensive and time-consuming. To save time and effort, indirect methods to obtain Cc may be an inexpensive option. Usually, the indirect methods are based on a correlation between some easier measuring descriptive variables such as liquid limit, soil density, and natural water content. This study used the ANFIS and regression methods to obtain Cc indirectly. To achieve the aim of this investigation, 177 undisturbed samples were collected from the cohesive soil in Sulaymaniyah Governorate in Iraq. Results of this study indicated that ANFIS models over-performed the Regression method in estimating Cc with R2 of 0.66 and 0.48 for both ANFIS and Regre
... Show MoreUtilizing phase change materials in thermal energy storage systems is commonly considered as an alternative solution for the effective use of energy. This study presents numerical simulations of the charging process for a multitube latent heat thermal energy storage system. A thermal energy storage model, consisting of five tubes of heat transfer fluids, was investigated using Rubitherm phase change material (RT35) as the. The locations of the tubes were optimized by applying the Taguchi method. The thermal behavior of the unit was evaluated by considering the liquid fraction graphs, streamlines, and isotherm contours. The numerical model was first verified compared with existed experimental data from the literature. The outcomes re
... Show MoreThe rapid advancements in wireless technology and digital electronics have led to the widespread adoption of compact, intelligent devices in various aspects of daily life. These advanced systems possess the capability to sense environmental changes, process data, and communicate seamlessly within interconnected networks. Typically, such devices integrate low-power radio transmitters and multiple smart sensors, hence enabling efficient functionality across wide ranges of applications. Alongside these technological developments, the concept of the IoT has emerged as a transformative paradigm, facilitating the interconnection of uniquely identifiable devices through internet-based networks. This paper aims to provide a comprehensive ex
... Show MoreTo detect the amount of Rifampicin in bulk and medicinal dosage formulations, an accurate, and cost-effective UV spectrophotometric technique has been developed using the area under the peak to estimate the presence of Rifampicin. This range of wavelengths (300–356) nm was chosen. The method showed linearity in the 2-22 μg/mL range, with R2 being 0.9996. The developed method' linearity, detection limit, quantification limit, precision, repeatability, and accuracy were all statistically and experimentally validated. The suggested methodology can be used for routine quality control analysis of Rifampicin in pure form and in capsule dosage form, as demonstrated by the satisfactory recovery percentage results. This study explores the struct
... Show More