Background: Background : Patients with non-rheumatic atrial fibrillation have high risk of thromboembolism especially ischemic stroke usually arising from left atrial appendage .Transoesophageal echocardiography provides useful information for risk stratification in these patients as it detects thrombus in the left atrial or left atrial appendage. Objective : This study was conducted at Al-Kadhimiya Teaching Hospital to assess the prevalence of left atrial chamber thrombi in patients with chronic non-rheumatic atrial fibrillation using transoesophageal echocardiography and its clinical significance as well as to verify the superiority of transoesophageal over transthoracic echocardiography in the detection of these abnormalities. Type of the study: Cross sectional study.Patients and Methods : Forty (40) consecutive patients (11 female and 29 male), at a mean age of 46 ± 9 years (range 28–60) with chronic non-rheumatic Atrial fibrillation were enrolled to this prospective study between March 2006 and December 2006. Tansthoracic and transesophageal two dimensional , M- mode , Doppler, and color- flow echocardiography were obtained with a kretz diagnostic ultrasound system. Results : The prevalence of Left atrium thrombus was 12.5%, 5 patients from the total number which was 40 patients. All of them seen bytransoesophagealechocardiography and non are detected byTansthoracic echocardiography . All the left atrial thrombi were confined to the left atrial appendage (100%). Left atrial spontaneous echo contrast was detected in 10 patients 25% by transoesophageal echocardiography, but was not observed in patient bytransthoracic echocardiography. All the 5 thrombi were found in left atria were significantly associated with spontaneous echo contrast 100% (P-value <0.001), reduced left ventricle ejection fraction (p-value <0.05) , large left atrium diameter ( p-value <0.05) and low LAAV <20 cm/s (p-value <0.001) compared to those without thrombus . Conclusions : The study showed that the prevalence of left atrial thrombus and appendage is not uncommon in patients with non-rheumatic atrial fibrillation and is exclusively seen in patients with left atrial SEC. Low Left ventricle ejection fraction , large Left atrium diameter , and low Left atrial appendages velocity are significantly associated with subsequent thrombus formation , and is more sensitive in the detection of these abnormalities compared with transthoracic echocardiography
Electricity consumption for household purposes in urban areas widely affects the general urban consumption compared to other commercial and industrial uses, as household electricity consumption is affected by many factors related to the physical aspects of the residential area such as temperature, housing unit area, and coverage ratio, as well as social and economic factors such as family size and income, to reach the extent of the influence of each of the above factors on the amount of electricity consumed for residential uses, a selected sample of a residential area in the city of Baghdad was studied and a field survey conducted of the characteristics of that sample and the results analyzed and modeled statistically in relation to the amo
... Show MoreBackground: Masseter muscle is one of the most obvious muscles of mastication and considered as one indicator of jaw muscle activity. It has a major influence on the transverse growth of the midface and the vertical growth of the mandible. This study undertaken to determine the role of cephalometric analysis for discrimination between Cl I and Cl III skeletal relationships, determine the role of ultrasonography in determination of masseter muscle thickness, compare masseter muscle thickness between Cl I and Cl III skeletal relationships, and determine the effect of gender on masseter muscle thickness. Material and Method: The sample of the current study consisted of 70 Iraqi subjects 40 males and 30 females with age ranging 18-25 years. The
... Show MoreIn this work, electrochemical process was presented to polymerized eugenol on Gr.2 and Gr.5 titanium alloys before and after treated by Micro Arc Oxidation (MAO), where Gr.2 is commercial pure titanium and Gr.5 is Ti-6Al-4V dental alloys. The deposited layers were characterized by scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), X-ray diffraction (XRD), and Fourier transform infrared spectroscopy (FTIR). The adhesion strength of polymeric thin-film was estimation by using pull-off adhesion test and the result was the adhesion strength of PE was (1.23 MPa) on Gr.2 before MAO and increase to (1.98 MPa) on Gr.2 after MAO treatment. The corrosion behavior of Gr.2 and Gr.5 alloy in artificial saliva environment at
... Show MoreAbstract
The research attempted to find an explanation and solution to a problem related to the fluctuation and decrease In the rate of return on assets for the research sample banks during the duration of the research, The search started from the hypothesis that, The effect of salary Domiciliation on the banking profitability of a sample of Iraqi banks participating in the salary settlement system for the period (2016-2019),The research used the descriptive historical approach, the quantitative analytical approach and the statistical approach. The research reached a set of conclusions, the most important of which is The effect of salary Domiciliation on banking profitability was achieved in three banks
... Show MoreThe 1500m race event is part of the athletics system, and the continuous competition to break records and achieve the highest levels of achievement in athletics events, especially the 1500m race event, is one of the topics that occupies the minds of many people interested in achieving digital development for this event, given the distance of the race and the time it takes to complete it. Because it is unique from other events, it has characteristics that distinguish it from other events, despite it being a middle-distance event, which shares with them that its speed is measured by the step, which consists of the length of the step and its frequency. Increasing any of these two factors while keeping one of them constant or increasing
... Show MoreThis research dealt with the impact of internal control on tax performance using balanced scorecard indicators because of its special importance in improving tax performance and reform. The internal control system is a safety valve for senior management in all organizations, it plays an important role in the regularity and development of work and the fight against corruption To provide reliable and accurate data and information, follow up on compliance with laws, regulations and instructions. The aim of this research is to demonstrate how control affects tax performance and how to adapt internal control components to improve tax performance. In the General Authority for taxes and its branches,. The research resulted in a number of conclu
... Show MoreIs hardly day expire without hearing the news either Abuse Managementthe accounting standards or the existence of serious misstatements by someauditors.Which caused the demanding of many companies in the recent republication of the financial statements and the re-announcement of its financialresults. Such acts raise questioning about the role that should be played by theauditors, prompting agencies responsible for setting auditing standards to takeTo throw increasingly responsibility on the auditors in order to interest risksfraud The Risks of Fraud in their review of the financial statements.also The Public Company Accounting Oversight Board in the U.S.called about the need of owning the Certified Public Accountants those whoaudits for
... Show MoreTwo dwarf snakes were discovered, Eirenis thospitis Schmidtler & Lanza from Sereen mountain, north east of Arbil and E. rothii Jan from Saffin mountain North of Arbil city North of Iraqi Kurdistan. Supported by description and important notes on variation. In addition summarized list for 9 species of the genus Eirenis Jan in Iraq is also presented.