Background: As photochemical reaction that can stiffen the cornea, CXL is the only promising method of preventing progression of keratectasia such as KC and secondary ectasia following refractive surgery. The aim of CXL is to stabilize the underlying condition with a small chance of visual improvement. Objective: To show the sequences of changes in visual acuity and topographic outcomes during 1 year post CXL for patients with progressive Keratoconus.Type of the study: Cross sectional studyMethods: CXL procedure was done for 45 eyes with progressive KC. The following parameters had been monitored pre operatively, 1, 3, 6 and 12 months postoperatively: K apex, K2, corneal thickness at thinnest location, anterior and posterior elevation points, BCVA and UCVA. Placido –Scheimpflug topography (Sirius) device had been used to monitor the corneal parameters of the study. One –way ANOVA and Paired sample T test was used for statistical analysis.The study done in Lasik specialty center /Baghdad/IraqResults: At 1 year, an averages flattening of (2.11 D) diopter in K2 and (1.88 D) diopter in K apex were found. Mean BCVA improved by 1 line from (0.18) Log MAR to (0.13) Log MAR and mean UCVA improved by 3.5 lines from (0.89) to (0.64) log MAR. The corneal thickness at thinnest location was 5.71 Mm less than the baseline. All the above mentioned parameters showed a trend of worsening between the baseline and 1 month, and improvement thereafter. We found no statistically significant changes in the anterior elevation points while the posterior elevation point changed (increased) significantly.Conclusions: Corneal collagen cross-linking seems to be effective in decreasing progression of KC , with improvements in optical measures in many patients. Post operative parameters discussed within this review followed a seemingly reproducible trend in there natural course over 12 months .Generally, the trend that observed was immediate worsening between baseline and 1 month resolution at approximately 3 months, and improvement thereafter.
The study addresses the problem of stagnation and declining economic growth rates in Arab countries since the eighties till today after the progress made by these countries in the sixties of the last century. The study reviews the e
... Show MoreGlutathione S-transferases (GSTs) are enzymes that included, in a more range of detoxifying reactions by conjugation of glutathione, to electrophilic material. Polymorphisms n the genes that responsible of GSTs affect, the function of the GSTs. GSTs play an active role in protection of cell against oxidative stress mechanism. Polymorphisms of GSTP1 at codon 105 amino acids forms GSTP1 important site for bind of hydrophobic electrophiles and the substitution of Ile/Val affect substrate specially catalytic activity of the enzyme and may correlate with reach to different diseases in human like diabetes mellitus type2 disease. Correlation between these polymorphisms and changes in the parameters file of diabetic patients has also bee
... Show MoreBackground : Carpal tunnel syndrome (CTS) is the most common entrapment neuropathy of upper extremities and Open carpal tunnel release is the most frequent surgical procedure and the gold standard for cases that do not respond to conservative treatment. Aims :This study is used to evaluate the functional outcome of limited palmar mini-incision of carpal tunnel release. This study aims to determine the safety and symptomatic and functional efficacy of median nerve decompression with limited incision in carpal tunnel syndrome surgery. Patients and methods:Carpal tunnel release with a 1.5-2 cm limited palmar incision was performed on 20 patients. Patients were evaluated initially at one month after treatment according to symptom severity
... Show MoreBackground: Corticotomy-assisted orthodontic treatment is done to induce a state of increased tissue turnover and transient osteopenia, which is followed by a faster rate of orthodontic tooth movement. It considered as an adjunct treatment option for orthodontic treatment of adults. The aim of this Study was to elucidate the effectiveness of a new surgical approach for acceleration of maxillary canine retraction in human with laser assisted flapless corticotomy and evaluate its effect on vitality of pulp and gingival sulcus depth. Materials and methods: the sample comprised of 15 Iraqi patients (9 females and 6 males; mean age 21.7), who were required extraction for their maxillary first premolars followed by retraction of the canines as pa
... Show MoreIn the present work, heterojunction diode detectors will be prepared using germanium wafers as a substrate material and 200 nm tin sulfide thickness will be evaporated by using thermal evaporation method as thin film on the substrate. Nd:YAG laser (λ=532 nm) with different energy densities (5.66 J/cm2 and 11.32 J/cm2) is used to diffuse the SnS inside the surface of the germanium samples with 10 laser shots in different environments (vacuum and distilled water). I-V characteristics in the dark illumination, C-V characteristics, transmission measurements, spectral responsivity and quantum efficiency were investigated at 300K. The C-V measurements have shown that the heterojunction were of abrupt type and the maximum value of build-in pot
... Show MoreIn most manufacturing processes, and in spite of statistical control, several process capability indices refer to non conformance of the true mean (µc ) from the target mean ( µT ), and the variation is also high. In this paper, data have been analyzed and studied for a blow molded plastic product (Zahi Bottle) (ZB). WinQSB software was used to facilitate the statistical process control, and process capability analysis and some of capability indices. The relationship between different process capability indices and the true mean of the process were represented, and then with the standard deviation (σ ), of achievement of process capability value that can reduce the standard deviation value and improve production out of theoretical con
... Show MoreIn this research, beam expander, BEX, is explained and designed for illuminating the
remote flying target. The BEX is optically designed to be suited for Nd:YAG laser of given
specifications. The BEX is modified to be zoom one to meet the conditions of preventing the
receiving unit; i.e the photodetector, from getting saturated at near and far laser tracking.
Decollimation could be achieved by automatic motor, which controls zoom lens of the BEX
according to the required expansion ratio of beam expander