Preferred Language
Articles
/
jkmc-339
Evaluation of the Intrinsic Pathway of Coagulation in a Sample of Iraqi Patients with Acute Myocardial Infarction
...Show More Authors

Background: Acute myocardial infarction (AMI) is one of the most common diagnoses in hospitalized patients. Increased plasma hemostatic markers were noted in acute myocardial infarction, indicating that the blood coagulation system is highly activated in those patients. Aims of the study: To study the level of intrinsic coagulation factors including (FVIII:C, FIX:C ,FXI:C ,FXII:C ) in patients with acute myocardial infarction. Type of the study: Cross –sectional study. Methods: Thirty patients (their age range is 48-68 years) were included in this study (9 female, 21 male) who were just admitted to the coronary care unit in AL-Yarmouk Teaching Hospital and diagnosed as having acute myocardial infarction patients, blood samples were taken from those patients . Twenty healthy subjects (6 female, 14 male) age and sex matched with the patients were included as a control group. The following investigations were done for both groups: 1.Packed cell volume(PCV%) .by microhaematocrit method. 2.FVIII:C assay. [ by parallel line bioassay of coagulationfactors]. 3.FIX:C assay. 4.FXI:C assay. 5.FXII:C assay. Results Mean FVIII:C (162.63%±17.22)was significantly (P value< 0.05)higher in patients with acute myocardial infarction than control group(94.70%±9.34).1-Mean FIX:C (151.20%±14.20) was significantly (P value <0.05) higher in acute myocardial infarction group than control group(94.10±8.51). 2-Mean FXI:C (146.30%±7.87) was significantly (P value <0.05) higher in acute myocardial infarction group than control group (102.00%±7.91). 3-Mean FXII:C(71.03±11.46) was significantly (P value <0.05) lower in acute myocardial infarction group than control group (119.00%±8.52). 4-There is inverse relationship between FXI:C and FXII:C in acute myocardial infarction group(P value -0.736). Conclusions Patients with acute myocardial infarction had significantly higher levels of FVIII:C,FIX:C,FXI:C than controls. FXII:C level was significantly lower in patients with acute myocardial infarction than control group. There is an inverse relationship between FXI:C and F XII:C in patients with acute myocardial infarction.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Oct 29 2019
Journal Name
Journal Of Engineering
Demand Priority in a Power System With Wind Power Contribution Load Shedding Scheme Based
...Show More Authors

The load shedding  scheme has been extensively implemented as a fast solution for unbalance conditions. Therefore, it's crucial to investigate supply-demand balancing in order to protect the network from collapsing and to sustain stability as possible, however its implementation is mostly undesirable. One of the solutions to minimize the amount of load shedding is the integration renewable energy  resources, such as wind power, in the electric power generation could contribute significantly to minimizing power cuts as it is ability to positively improving the stability of the electric grid. In this paper propose a method for shedding the load base on the priority demands with incorporating the wind po

... Show More
View Publication Preview PDF
Crossref (9)
Crossref
Publication Date
Tue Mar 09 2021
Journal Name
Romanian Neurosurgery
Primary multiple cerebral hydatid disease in a young patient with surgically-treated intracerebral haemorrhage
...Show More Authors

Introduction:  Cerebral hydatid disease (CHD) is rare and the multiple-cystic variety is even rarer. In this paper, we report a case of multiple CHD and explore a possible link with a preceding spontaneous intracerebral haemorrhage (ICH).   Case presentation: A 27-year old gentleman with a history of surgically-evacuated, spontaneous ICH presented with severe headache, left-sided weakness - Medical Research Council (MRC) grade II - and recurrent tonic-clonic seizures, while on a full dose of anti-epileptic medication. Brain magnetic resonance imaging (MRI) scans showed multiple intra-axial cystic lesions in the right hemisphere. The cysts were removed intact using Dowling’s technique through a large temporoparietal crani

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Thu Jul 01 1999
Journal Name
Bulletin Of The Iraq Natural History Museum (p-issn: 1017-8678 , E-issn: 2311-9799)
Some leaf hopper and a plant hopper with their populations in Abu-Ghraib, Iraq
...Show More Authors

Seven leafhoppers (Cicadeilidae). and one plantboppei (Delpbacidae), Homoptera were identified from a one year operated light trap at the College of Agiculture farm in Abu¬Ghraib. The leafhoppers were: Balclutha hortensis Lind.; B. rufaofasciata Merine.; psammctettix alien us Dahlbem.; P. striatus L.; Extianus capicola.; Neoaliturus haematoceps H. R.; and Orozius albicnctus Dist. The planthopper was Sogatella vibix Haupt. one year records of their populations, indicated that B. rufofasciata occured during the fall from October 10 until December 18; E. capicola from October 24 until November 21 and again in the summer from March to October. The others occured only during the summer, from the end of March and early April until Mid-Septemb

... Show More
View Publication Preview PDF
Publication Date
Tue Jan 01 2019
Journal Name
Indian Journal Of Public Health Research &amp; Development
Post-Traumatic Stress Disorder among Women with Breast Cancer in Iraq: A Preliminary Report
...Show More Authors

View Publication
Scopus (2)
Crossref (2)
Scopus Crossref
Publication Date
Mon Jun 19 2023
Journal Name
Journal Of Engineering
Study of Some Mechanical Properties for a Polymer Material Reinforcement with Chip or Powder Copper
...Show More Authors

In this paper, chip and powder copper are used as reinforcing phase in polyester matrix to form composites. Mechanical properties such as flexural strength and impact test of polymer reinforcement copper (powder and chip) were done, the maximum flexural strength for the polymer reinforcement with copper (powder and chip) are (85.13 Mpa) and (50.08 Mpa) respectively was obtained, while the maximum observation energy of the impact test for the polymer reinforcement with copper (powder and chip) are (0.85 J) and (0.4 J) respectively  

View Publication Preview PDF
Crossref
Publication Date
Wed Aug 21 2019
Journal Name
Al-khwarizmi Engineering Journal
Design and Optimization of a Surface-Mounted Permanent-Magnet Linear Synchronous Motor with Maxwell ANSYS
...Show More Authors

Linear motor offers several features in many applications that require linear motion. Nevertheless, the presence of cogging force can deteriorate the thrust of a permanent magnet linear motor. Using several methodologies, a design of synchronous single sided linear iron-core motor was proposed. According to exact formulas with surface-mounted magnets and concentrated winding specification, which are relying on geometrical parameters. Two-dimensional performance analysis of the designed model and its multi-objective optimization were accomplished as a method to reduce the motor cogging force using MAXWELL ANSYS. The optimum model design results showed that the maximum force ripple was approximatrly reduced by 81.24%compared to the origina

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Wed Jan 04 2023
Journal Name
Frontiers In Chemestry
Thermal and flow performance analysis of a concentrated linear Fresnel solar collector with transverse ribs
...Show More Authors

This article deals with the impact of including transverse ribs within the absorber tube of the concentrated linear Fresnel collector (CLFRC) system with a secondary compound parabolic collector (CPC) on thermal and flow performance coefficients. The enhancement rates of heat transfer due to varying governing parameters were compared and analyzed parametrically at Reynolds numbers in the range 5,000–13,000, employing water as the heat transfer fluid. Simulations were performed to solve the governing equations using the finite volume method (FVM) under various boundary conditions. For all Reynolds numbers, the average Nusselt number in the circular tube in the CLFRC system with ribs was found to be larger than that of the plain abs

... Show More
Scopus (7)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Thu Jan 23 2020
Journal Name
Acoustics Australia
Absorption Coefficient of a Double-Layer Inhomogeneous Micro-perforated Panel Backed with Multiple Cavity Depths
...Show More Authors

Double-layer micro-perforated panels (MPPs) have been studied extensively as sound absorption systems to increase the absorption performance of single-layer MPPs. However, existing proposed models indicate that there is still room for improvement regarding the frequency bands of absorption for the double-layer MPP. This study presents a double-layer MPP formed with two single MPPs with inhomogeneous perforation backed by multiple cavities of varying depths. The theoretical formulation is developed using the electrical equivalent circuit method to calculate the absorption coefficient under a normal incident sound. The simulation results show that the proposed model can produce absorption coefficient with wider absorption bandwidth compared w

... Show More
View Publication
Scopus (21)
Crossref (19)
Scopus Clarivate Crossref
Publication Date
Thu Aug 01 2019
Journal Name
مجلة العلوم الاقتصادية والإدارية
Improving" Jackknife Instrumental Variable Estimation method" using A class of immun algorithm with practical application
...Show More Authors

Improving" Jackknife Instrumental Variable Estimation method" using A class of immun algorithm with practical application

Publication Date
Sat Oct 16 2021
Journal Name
Energies
Performance Analysis of a Solar Cooling System with Equal and Unequal Adsorption/Desorption Operating Time
...Show More Authors

In solar-thermal adsorption/desorption processes, it is not always possible to preserve equal operating times for the adsorption/desorption modes due to the fluctuating supply nature of the source which largely affects the system’s operating conditions. This paper seeks to examine the impact of adopting unequal adsorption/desorption times on the entire cooling performance of solar adsorption systems. A cooling system with silica gel–water as adsorbent-adsorbate pair has been built and tested under the climatic condition of Iraq. A mathematical model has been established to predict the system performance, and the results are successfully validated via the experimental findings. The results show that, the system can be operational

... Show More
View Publication
Scopus (11)
Crossref (12)
Scopus Clarivate Crossref