Preferred Language
Articles
/
jkmc-325
The Functional Results of Surgical Percutaneous Joystick Reduction Therapy for Isolated Severely Angulated Radial Neck Fracture in Children
...Show More Authors

Background: Radial neck fractures in children account for 5 to 10% of all elbow fractures in children. They are extra-articular fractures of the radius proximal to the bicipital tuberosity. The physis is typically involved as a Salter-Harris I or II pattern. Alternatively, the fracture sometimes is extraphyseal, through the metaphysis. In children there is considerable potential for remodeling after these fractures. Up to 30° of radial head tilt and up to 3 mm of transverse displacement are acceptable. Many modalities of treatment are available regarding Surgical &Non-Surgical treatments. Objectives: To evaluate the functional outcome after surgical percutaneous joystick reduction therapy of severely angulated radial neck fracture in children. Type of the study: A prospective study. Methods: During the period between February/2012 and May/2015, we made a prospective study of (18) patients suffered from O′Brien type II&III radial neck fracture with severe angulation that require surgery seen at Al-Kindy Teaching Hospitals. However, we select a group of children who had more than 30° of Radial head angulation really cannot treated by conservative method. Angulated radial neck fractures in children reduced with a percutaneous Kirschner wire. We select of surgical procedure after failure of thumbing intraoperatively. The primary indication for surgery was changing type II&III to typeI which can go on in manage conservatively. Results: All the (18) patients treated with percutaneous pinning techniques were followed-up, clinically and radiographically evaluated pre-surgery, post-surgery and finally (6) months after surgery. The mean angulation of the fractures was 64° (30° - 90°) before reduction and 10°(0° - 22°) after reduction. Mean fracture displacement after reduction in all cases was less than 3 mm. Range of Motion (ROM) in flexion, extension, pronation and supination was the functional parameter in our study as graded by (the grading system of Steele). We obtained an outcome of excellent results in 15 patient (83%), good results in 3 patients (17%) and we have no fair or poor results. Conclusions Percutaneous Joystick Reduction Techniqueusing K-wire in children with radial neck fractures is a safe, short, easy procedure requires only good technical measures, minimally invasive in nature with minimal hospitalization time, has a minimal morbidity and complication rates, it is recommended surgical treatment that can achieve recovery of normal radial neck angulation, elbow motion and yielding excellent results.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Apr 01 2024
Journal Name
Heliyon
Ground effect of an inverted double element wing diffuser on a sedan car
...Show More Authors

View Publication
Scopus (3)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Thu Dec 01 2022
Journal Name
Environmental Nanotechnology, Monitoring & Management
Boosted visible-light-driven photocatalytic degradation of lomefloxacin over α-Ag2WO4/NiSx nanocomposites
...Show More Authors

Scopus (13)
Crossref (5)
Scopus Crossref
Publication Date
Sun Jan 23 2022
Journal Name
Buildings
Structural Efficiency of Non-Prismatic Hollow Reinforced Concrete Beams Retrofitted with CFRP Sheets
...Show More Authors

Non-prismatic reinforced concrete (RC) beams are widely used for various practical purposes, including enhancing architectural aesthetics and increasing the overall thickness in the support area above the column, which gives high assurance to services that this will not result in the distortion of construction features and can reduce heights. The hollow sections (recess) can also be used for the maintenance of large structural sections and the safe passage of utility lines of water, gas, telecommunications, electricity, etc. They are generally used in large and complex civil engineering works like bridges. This study conducted a numerical study using the commercial finite element software ANSYS version 15 for analysing RC beams, hol

... Show More
View Publication Preview PDF
Scopus (11)
Crossref (11)
Scopus Clarivate Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Construction Research Congress
Exploratory Study of Potential Negative Safety Outcomes Associated with UAV-Assisted Construction Management
...Show More Authors

Scopus (13)
Scopus
Publication Date
Sun May 01 2022
Journal Name
Journal Of Engineering
Attitude and Altitude Control of Quadrotor Carrying a Suspended Payload using Genetic Algorithm
...Show More Authors

The need for quick airborne transportation is critical, especially in emergencies. Drones with suspended payloads might be used to accomplish quick airborne transportation. Due to the environment or the drone's motion, the slung load may oscillate and lead the drone to fall. The altitude and attitude controls are the backbones of the drone's stability, and they must be adequately designed. Because of their symmetrical and simple structure, quadrotor helicopters are one of the most popular drone classes. In this work, a genetic algorithm with two weighted terms fitness function is used to adjust a Proportional-Integral-Derivative (PID) controller to compensate for the altitude and attitude controllers in a quadrotor drone with a slun

... Show More
View Publication
Crossref (5)
Crossref
Publication Date
Wed Dec 27 2017
Journal Name
Al-khwarizmi Engineering Journal
An Experimental Study of Capillary Tubes Behavior With R-12 and R-134a
...Show More Authors

 

Experimental work has been performed on three capillary tubes of different lengths and diameters using R-12 and R-134a. The test also studies the effect of discharge and speed of evaporator fan. The results clearly showed that refrigerant type and discharge significantly influence the temperature drop across the capillary tube. While the speed of evaporator fan has small effect. Experimental results showed that the temperature gradient for the two refrigerants are the same, but after approximatly one meter the temperature gradient of R-134a  is steeper than R-12.

 

View Publication Preview PDF
Publication Date
Thu Jun 30 2016
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Adsorption of Fluoroquinolones Antibiotics on Activated Carbon by K2CO3 with Microwave Assisted Activation
...Show More Authors

The preparation of low cost activated carbon from date stones and microwave method by using K2CO3 as chemical activator were investigated.

   The prepared activated carbon was used to remove fluoroquinolones antibiotics from aqueous solution. The characterizations of the activated carbon is represented by surface area, pore volume, ash content, moisture content, bulk density, and iodine number. The adsorbed fluoroquinolones antibiotics are Ciprofloxcin (CIP), Norfloxcin (NOR) and Levofloxcin (LEVO). Different variables as pH, initial concentrations and contact time were studied to show the efficieny of prepared activated carbon. The experimental adsorption data were analyzed by Lungmuir, Freundlich

... Show More
View Publication Preview PDF
Publication Date
Wed Oct 18 2023
Journal Name
Iraqi National Journal Of Nursing Specialties
Effect of Purified l-Hydroxyphenazine Pigment on Lymphocytes Viability Against Experimental Secondary Hydatidosis
...Show More Authors

Objectives: To find out the effect of l-hydroxyphenazine (1-HP) on viability of T-lymphocytes and the reflects of this
effect on experimental hyadatidosis on hydatid cyst protoscoleces infectivity in vivo.
Methodology: Four groups of white male /ه/mice were experimentally infected with four concentrations of (1-HP)
with challenge dose of 2000 protoscoleces /1 ml with negative (9.8.5) and positive (P.H.A) control groups.
Results: It has been found that the higher concentrations (75,100) 1101/111 of the (1-HP) causes significant
decrement in the lymphocytes viability in comparison with negative and positive control groups. (060.01).
Recommendations: The study recommended using concentrations lower than 25 pmole Iml which

... Show More
View Publication Preview PDF
Publication Date
Mon Mar 01 2021
Journal Name
Iraqi Journal Of Physics
Studying of Plasma- Polymerized Pyrrole at Variable Gas Flow Rates Via Plasma Jet
...Show More Authors

     In this manuscript has investigated the synthesis of plasma-polymerized pyrrole (C4H5N) nano-particles prepared by the proposed atmospheric pressure nonequilibrium plasma jet through the parametric studies, particularly gas flow rate (0.5, 1 and 1.5 L/min). The plasma jet which used operates with alternating voltage 7.5kv and frequency 28kHz. The plasma-flow characteristics were investigated based on optical emission spectroscopy (OES). UV-Vis spectroscopy was used to characterize the  oxidization  state for polypyrrole. The major absorption appears around 464.1, 449.7 and 435.3  nm at the three flow rate of argon gas. The chemical composition and structural properties of the

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Sep 12 2019
Journal Name
Al-kindy College Medical Journal
K. wire fixation versus conservative treatment of closed displaced intra-articular calcaneal fractures
...Show More Authors

Background: Calcaneus is a spongy cancellous bone with rich blood supply , its fracture heals more rapidly providing no occurrence of infection and soft tissue injury around ,no gross malposition of fragments. The associated pain leads to a major impairment in life quality. The aim of treatment for calcaneal fractures is the decrease of pain and rebuilding of walking ability for patients with normal foot shape and the ability to wear normal foot wear. To reduce complications, a minimally invasive technique for the treatment of displaced intra-articular fractures of the calcaneus was preferred to use.

The purpose of this study was to determine whether the closed reduction and percutaneous K. wire fixation of displ

... Show More
View Publication Preview PDF
Crossref