Preferred Language
Articles
/
jkmc-325
The Functional Results of Surgical Percutaneous Joystick Reduction Therapy for Isolated Severely Angulated Radial Neck Fracture in Children
...Show More Authors

Background: Radial neck fractures in children account for 5 to 10% of all elbow fractures in children. They are extra-articular fractures of the radius proximal to the bicipital tuberosity. The physis is typically involved as a Salter-Harris I or II pattern. Alternatively, the fracture sometimes is extraphyseal, through the metaphysis. In children there is considerable potential for remodeling after these fractures. Up to 30° of radial head tilt and up to 3 mm of transverse displacement are acceptable. Many modalities of treatment are available regarding Surgical &Non-Surgical treatments. Objectives: To evaluate the functional outcome after surgical percutaneous joystick reduction therapy of severely angulated radial neck fracture in children. Type of the study: A prospective study. Methods: During the period between February/2012 and May/2015, we made a prospective study of (18) patients suffered from O′Brien type II&III radial neck fracture with severe angulation that require surgery seen at Al-Kindy Teaching Hospitals. However, we select a group of children who had more than 30° of Radial head angulation really cannot treated by conservative method. Angulated radial neck fractures in children reduced with a percutaneous Kirschner wire. We select of surgical procedure after failure of thumbing intraoperatively. The primary indication for surgery was changing type II&III to typeI which can go on in manage conservatively. Results: All the (18) patients treated with percutaneous pinning techniques were followed-up, clinically and radiographically evaluated pre-surgery, post-surgery and finally (6) months after surgery. The mean angulation of the fractures was 64° (30° - 90°) before reduction and 10°(0° - 22°) after reduction. Mean fracture displacement after reduction in all cases was less than 3 mm. Range of Motion (ROM) in flexion, extension, pronation and supination was the functional parameter in our study as graded by (the grading system of Steele). We obtained an outcome of excellent results in 15 patient (83%), good results in 3 patients (17%) and we have no fair or poor results. Conclusions Percutaneous Joystick Reduction Techniqueusing K-wire in children with radial neck fractures is a safe, short, easy procedure requires only good technical measures, minimally invasive in nature with minimal hospitalization time, has a minimal morbidity and complication rates, it is recommended surgical treatment that can achieve recovery of normal radial neck angulation, elbow motion and yielding excellent results.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Feb 24 2015
Journal Name
Robotica
Multi-level control of zero-moment point-based humanoid biped robots: a review
...Show More Authors
SUMMARY<p>Researchers dream of developing autonomous humanoid robots which behave/walk like a human being. Biped robots, although complex, have the greatest potential for use in human-centred environments such as the home or office. Studying biped robots is also important for understanding human locomotion and improving control strategies for prosthetic and orthotic limbs. Control systems of humans walking in cluttered environments are complex, however, and may involve multiple local controllers and commands from the cerebellum. Although biped robots have been of interest over the last four decades, no unified stability/balance criterion adopted for stabilization of miscellaneous walking/running modes of biped </p> ... Show More
View Publication
Scopus (46)
Crossref (42)
Scopus Clarivate Crossref
Publication Date
Thu Apr 01 2021
Journal Name
Basra Journal Of Science
Preparation and Characterization of Polyvinylpyrrolidone/Multi-walled Carbon Nanotubes Nanocomposite hybrid with Graphene
...Show More Authors

In this work, polyvinylpyrrolidone (PVP), Multi-walled carbon nanotubes (MWCNTs) nanocomposite was prepared and hybrid with Graphene (Gr) by casting method. The morphological and optical properties were investigated. Fourier Transformer-Infrared (FT-IR) indicates the presence of primary distinctive peaks belonging to vibration groups that describe the prepared samples. Scanning Electron Microscopy (SEM) images showed a uniform dispersion of graphene within the PVP-MWCNT nanocomposite. The results of the optical study show decrease in the energy gap with increasing MWCNT and graphene concentration. The absorption coefficient spectra indicate the presence of two absorption peaks at 282 and 287 nm attributed to the π-π* electronic tr

... Show More
View Publication Preview PDF
Scopus (7)
Crossref (5)
Scopus Crossref
Publication Date
Fri Sep 21 2018
Journal Name
Materials Research Express
Geometries, electronic properties and stability of molybdenum and tungsten nitrides low-index surfaces
...Show More Authors

Motivated by the vital role played by transition metal nitride (TMN) composites in various industrial applications, the current study reports electronic properties, thermodynamic stability phase diagram, and vacancy formation energies of the plausible surfaces of NiAs and WC-type structures of δ3-MoN and δ-WN hexagonal phases, respectively. Low miller indices of various surface terminations of δ3-MoN and δ-WN namely, (100), (110), (111), and (001) have been considered. Initial cleaving of δ3-MoN bulk unit cell offers separate Mo and N terminations signified as δ3-MoN (100): Mo, δ3-MoN(100):N, δ3-MoN(111):Mo, δ3-MoN(111):Mo, and δ3-MoN(001):Mo. However, the (110) plane reveals mix-truncated with both molybdenum and nitrogen atoms i

... Show More
View Publication
Scopus (15)
Crossref (13)
Scopus Clarivate Crossref
Publication Date
Sat Jul 01 2023
Journal Name
Journal Of Physics: Conference Series
Mixed Ligand Complexes of Schiff Base and Nicotinamide: Synthesis, Characterization and Antimicrobial Activities
...Show More Authors

A new Schiff base of HL has been synthesized from amoxicillin drug and 4- Chlorobenzophenone. Cr (III), Fe (III), Co (II), Ni (II), Cu (II), Cd (II) and Hg (II) mixed ligands complexes of Schiff base and Nicotinamide. Diagnosis of synthesis ligand and its complexes are done by 1HNMR, 13CNMR and thermal analysis for HL ligand, FTIR, UV-visible, molar conductance, CHN analysis, magnetic susceptility and atomic absorption. Octahedral geometries have been suggested for all complexes. All compounds under study were tested antimicrobial activity against four type of bacteria such as Pseudomonas aeruginosa, Escherichia coli, Staphylococcus aureus Bacillis subtilis in nutrient agar.

Preview PDF
Scopus (3)
Scopus
Publication Date
Thu Jun 30 2011
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
CRACKING ACTIVITY OF PREPARED Y-ZEOLITE CATALYST USING CUMENE ON FLUIDIZED BED REACTOR
...Show More Authors

The catalytic activity of faujasite type NaY catalysts prepared from local clay (kaolin) with different Si/Al ratio was studied using cumene cracking as a model for catalytic cracking process in the temperature range of 450-525° C, weight hourly space velocity (WHSV) of 5-20 h1, particle size ≤75μm and atmospheric pressure. The catalytic activity was investigated using experimental laboratory plant scale of fluidized bed reactor.
It was found that the cumene conversion increases with increasing temperature and decreasing WHSV. At 525° C and WHSV 5 h-1, the conversion was 42.36 and 35.43 mol% for catalyst with 3.54 Si/Al ratio and Catalyst with 5.75 Si/Al ratio, respectively, while at 450° C and at the same WHSV, the conversion w

... Show More
View Publication Preview PDF
Publication Date
Mon Jan 18 2021
Journal Name
Materials Science And Engineering
Properties of engineered cementitious composite concrete (bendable concrete) produced using Portland limestone cement
...Show More Authors

Bendable concrete, also known as Engineered Cementitious Composite (ECC) is a type of ultra-ductile cementitious composites reinforced with fibres to control the width of cracks. It has the ability to enhance concrete flexibility by withstanding strains of 3% and higher. The properties of bendable concrete mixes (compressive strength, flexural strength, and drying shrinkage) are here assessed after the incorporation of supplementary cementitious materials, silica fume, polymer fibres, and the use of ordinary Portland cement (O.P.C) and Portland limestone cement (IL). Mixes with Portland limestone cement show lower drying shrinkage and lower compressive and flexural strength than mixes with ordinary Portland cement, due to the ratio o

... Show More
Publication Date
Tue Nov 15 2022
Journal Name
Association Of Arab Universities Journal Of Engineering Sciences
A-mechanical properties of engineered cementitious composite concrete produced from Portland limestone cement
...Show More Authors

Conventional concretes are almost unbending, and even a small amount of strain potential leaves them brittle. This lack of bendability is a major source of strain loss, and it has been the main goal behind the development of bendable concrete, often known with engineered ce ment composites, or ECC. This form of concrete has a lot more flexibility than regular concrete. Micromechanical polymer fibers are used to strengthen ECC. In most cases, ECC uses a 2% amount of thin, separated fibers. As a result, bendable concrete deforms but unlike traditional concrete, it does not crack. This study aims to include this kind of concrete, bendable concrete, which can be used to solve concrete problems. Karasta (CK) and Tasluja (CT) Portland Lime

... Show More
Publication Date
Thu May 31 2012
Journal Name
Al-khwarizmi Engineering Journal
Extraction of Penicillin V from Simulated Fermentation Broth by Liquid-Liquid Membrane Technique
...Show More Authors

Liquid-liquid membrane extraction technique, pertraction, using three types of solvents (methyl isobutyl ketone, n-butyl acetate, and n-amyl acetate) was used for recovery of penicillin V from simulated fermentation broth under various operating conditions of pH value (4-6) for feed and (6-8) for receiver phase, time (0-40 min), and agitation speed (300-500 rpm) in a batch laboratory unit system. The optimum conditions for extraction were at pH of 4 for feed, and 8 for receiver phase, rotation speed of 500 rpm, time of 40 min, and solvent of MIBK as membrane, where more than 98% of penicillin was extracted. 

View Publication Preview PDF
Publication Date
Thu Sep 06 2018
Journal Name
Al-khwarizmi Engineering Journal
Performance Augmenting of a Vertical Axis Wind Turbine using Adaptable Convergent Ducting System
...Show More Authors

Developments are carried out to enhance the performance of vertical axis wind turbines (VAWT). This paper studies the performance of the ducted wind turbine with convergent duct (DAWT). Basically, the duct technique is utilized to provide the desired wind velocity facing the turbine. Methodology was developed to estimate the decisive performance parameter and to present the effect of the convergent duct with different inlet angles. The ducted wind turbine was analyzed and simulated using MATLAB software and numerically using ANSYS-Fluent 17.2. Result of both approaches were presented and showed good closeness for the two cases of covering angles 12  and 20 respectively. Results also showed that the convergent duct with an inlet angl

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Dec 30 2018
Journal Name
Journal Of Engineering
Abrasive Wear Characteristics of Composite Material (AA 7075 / SiC) Synthesized by Stir Casting
...Show More Authors

Aluminum Metal Matrix Composites (ALMMCs) was prepared by using stir casting technique for AA 7075 aluminum alloy as a matrix reinforced with SiC particles at various percentages (3, 6, 9 and 12 wt. % ) and 75µm in grain size. The prepared composite material can be used for many applications such as aerospace, automobiles and many industrial sectors. Abrasive wear test was carried out by two stages: the first stage was done by changing the emery papers at various grit sizes 180, 320, 500, and 1000µm with constant applied load 15N. While the second stage was carried out by changing the applied loads 5, 10, 15, 20 and 25N with constant emery paper at 320 µm grit size. Microstructure examination, hardness test and roughn

... Show More
View Publication Preview PDF
Crossref (3)
Crossref