Background: Radial neck fractures in children account for 5 to 10% of all elbow fractures in children. They are extra-articular fractures of the radius proximal to the bicipital tuberosity. The physis is typically involved as a Salter-Harris I or II pattern. Alternatively, the fracture sometimes is extraphyseal, through the metaphysis. In children there is considerable potential for remodeling after these fractures. Up to 30° of radial head tilt and up to 3 mm of transverse displacement are acceptable. Many modalities of treatment are available regarding Surgical &Non-Surgical treatments. Objectives: To evaluate the functional outcome after surgical percutaneous joystick reduction therapy of severely angulated radial neck fracture in children. Type of the study: A prospective study. Methods: During the period between February/2012 and May/2015, we made a prospective study of (18) patients suffered from O′Brien type II&III radial neck fracture with severe angulation that require surgery seen at Al-Kindy Teaching Hospitals. However, we select a group of children who had more than 30° of Radial head angulation really cannot treated by conservative method. Angulated radial neck fractures in children reduced with a percutaneous Kirschner wire. We select of surgical procedure after failure of thumbing intraoperatively. The primary indication for surgery was changing type II&III to typeI which can go on in manage conservatively. Results: All the (18) patients treated with percutaneous pinning techniques were followed-up, clinically and radiographically evaluated pre-surgery, post-surgery and finally (6) months after surgery. The mean angulation of the fractures was 64° (30° - 90°) before reduction and 10°(0° - 22°) after reduction. Mean fracture displacement after reduction in all cases was less than 3 mm. Range of Motion (ROM) in flexion, extension, pronation and supination was the functional parameter in our study as graded by (the grading system of Steele). We obtained an outcome of excellent results in 15 patient (83%), good results in 3 patients (17%) and we have no fair or poor results. Conclusions Percutaneous Joystick Reduction Techniqueusing K-wire in children with radial neck fractures is a safe, short, easy procedure requires only good technical measures, minimally invasive in nature with minimal hospitalization time, has a minimal morbidity and complication rates, it is recommended surgical treatment that can achieve recovery of normal radial neck angulation, elbow motion and yielding excellent results.
Abstract
The critical success factors of the means of the most modern in determining the main directions for organizations to achieve competitive advantage. and can be a critical success factors in organizations that overlap in the functional areas of the organization. that successful organizations use these factors to get to the uniqueness and distinction. as the entrance of critical success factors with the capacity Evaluative phase correction because discovery increases the perception of managers of what is important to the organization and using them to get to the Strategic Entrepreneurship. as it begins in terms of permanence of success and
... Show MoreHospitals are part of the service organizations and most importantly at the level of individuals because they are tied to the people health and their daily lives , the nursing service is one of the important services provided by hospitals, and nurses are the human resource that offers this service, from this standpoint the idea of research came to prepare work Scheduling for nurses in a scientific way to improve performance operational for their services and provide efficient service available 24 hours a day, the research use one of the modern and scientific rules of scheduling its “schedule of
... Show MoreThis research a study model of linear regression problem of autocorrelation of random error is spread when a normal distribution as used in linear regression analysis for relationship between variables and through this relationship can predict the value of a variable with the values of other variables, and was comparing methods (method of least squares, method of the average un-weighted, Thiel method and Laplace method) using the mean square error (MSE) boxes and simulation and the study included fore sizes of samples (15, 30, 60, 100). The results showed that the least-squares method is best, applying the fore methods of buckwheat production data and the cultivated area of the provinces of Iraq for years (2010), (2011), (2012),
... Show MoreThe purpose of this paper is to preparing exercises for using the (Blazepod) device for advanced basketball players, and then identifying the effect of using the (Blazepod) device in developing some of the player's defensive movement for advanced basketball players. 12 players from the Adhamiya Sports Club, the category of applicants for the 2022/2023 sports year, where they were chosen in a deliberate manner from the community of origin represented by clubs, and the researchers used the defender player's movement test, and the results of the study showed that the special exercises prepared by the researcher using the (Blazepod) device affected the development Defensive skills (the movement of the defending player) greatly increased among a
... Show MoreThe objective of this study is to examine the properties of Bayes estimators of the shape parameter of the Power Function Distribution (PFD-I), by using two different prior distributions for the parameter θ and different loss functions that were compared with the maximum likelihood estimators. In many practical applications, we may have two different prior information about the prior distribution for the shape parameter of the Power Function Distribution, which influences the parameter estimation. So, we used two different kinds of conjugate priors of shape parameter θ of the <
... Show MoreMany problems are facing the installation of piles group in laboratory testing and the errors in results of load and settlement are measured experimentally may be happened due to select inadequate method of installation of piles group. There are three main methods of installation in-flight, pre-jacking and hammering methods. In order to find the correction factor between these methods the laboratory model tests were conducted on small-scale models. The parameters studied were the methods of installation (in-flight, pre-jacking and hammering method), the number of piles and in sandy soil in loose state. The results of experimental work show that the increase in the number of piles value led to increase in load carrying ca
... Show More