Preferred Language
Articles
/
jkmc-31
Clinical and experimental Study to evaluate the effect of Biphasic calcium phosphate collagen composite (cpcc) on healing of bone defects after oral surgical procedures
...Show More Authors

Background: A recent discoveries used for reconstruction in maxillofacial surgery is the composite bone graft materials. The availability of collagen I matrix make our choice to use this material in surgery .It is biomaterials that its structure could be modified by simple techniques. Studies to find a new materials use for bone reconstruction is to overcome the disadvantages of autogenous bone and the synthetic resorbable bone substitutes.

Objectives: This study was done to evaluate the effect of biphasic calcium phosphate collagen composite (ccpc) on healing of bone defects after oral surgical procedures.

Type of the study: A cross sectional study.

Method: It involved 60 patients, 35 male and 25 female, age (15-40) yearsand experimental animals study involved sixty rabbits.The study was done in Department of Maxillofacial surgery in Al anbarCollege of Dentistry (2015-2016).These patients were received tooth extraction, and other minor surgical procedures .Clinical and radiographical examination and patients consents are done before surgery. The surgery was done under local anesthesia.The resulting bone cavities are filled with composite bone graft material composed from combination of lyophilized hydrolysed collagen sponge (Hemospon),Brasil and Osteon II bone graft material,Korea .The area is closed with 3/0 block silk suture .Antibiotic cover (Ampicillin 500mg ×4) for 1 week was prescribed. The patients were followed up by careful clinical examination with radiograph 15-30 days after surgery. .Sixty New Zeleandi White rabbit were used in our study for histopathologicalexamination.Intraperitoneal injection of ketamine 10 mg with XYL-M2 solution 20 mg xylazine base used to anesthetize the animals. (5mm diameter) bone defects were made using straight surgical hand piece and bur in anterior mandibular region and filled with each material.  The study design involve the following groups: group 1( involve 15 rabbit; the defect was made and filled with blood clot only (control group),group 2( involve 15 rabbit, the defect was made and filled with collagen sponge only),group 3(Involve 15 rabbit, the defect was made and filled with Osteon II bone graft only),group4( involve 15 rabbit, the defect was made and filled with Osteon II bone graft +collagen (Composite bone graft).The flap were closed 3/0 black silk suture. The rabbits were killed after 30 days. 10 cmexcisional biopsy specimen was taken from the paramandibular area and placed in 10%formalin then send histopathologicalexamination.

Results:  Clinically, the treated area show good healing with absence of infection .Radiographs during follow up period show radiopacity indicating new bone formation .The results of experimental animals (Rabbits) indicategrowth new bone . In group 1 and group2, the center of the defects was depressed by surrounding tissues  Eung et al, While, in group 3&group 4, the graft materials maintained the space and the center of the defect did not depress. Statistical analysis indicates that during 4 th week ,the highest healing % is (100%) in group 3 &group4 in compared to control group (50%)..A significant difference in healing % was found among the treated groups.

Conclusion:The result indicates that biphasic calcium phosphate collagen composite can be efficiently utilized clinically.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Sep 15 2024
Journal Name
Journal Of Baghdad College Of Dentistry
The reliability of insertion torque as an indicator for primary stability in immediate dental implant: A prospective clinical study
...Show More Authors

Background: The primary stability of the dental implant is a crucial factor determining the ability to initiate temporary implant-supported prosthesis and for subsequent successful osseointegration, especially in the maxillary non-molar sites. This study assessed the reliability of the insertion torque of dental implants by relating it to the implant stability quotient values measured by the Osstell device. Material and methods: This study included healthy, non-smoker patients with no history of diabetes or other metabolic, or debilitating diseases that may affect bone healing, having non-restorable fractured teeth and retained roots in the maxillary non-molar sites. Primary dental implant stability was evaluated using a torque ratc

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Mon Jul 28 2025
Journal Name
Al–bahith Al–a'alami
SPECIALIZED JOURNALISM IN IRAQ : (After The Events of 09-04-2003)
...Show More Authors

The specialized Journalism plays an important role in our daily lives using all of its different ways, including news, caricature, commentary and dialogue. The specialized Journalism deserves vigilance and interest for it is caring about having a new media system. It is meant by “specialization”, first: identifying the areas of work in which the person concerned possesses great knowledge in the specialty resulting from a long experience, it also means being able to continuously develop required skills in that specialty. The specialization is not only a feature of the press, but also a feature of human development; thousands of years ago, the primitive society consisted of people from different specializations: fishermen, farmers, her

... Show More
View Publication
Publication Date
Tue Jun 30 2009
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
The Effect of Extraction Temperature and Solvent to Oil Ratio on Viscosity Index of Mixed-medium Lubricating Oil Fraction by Using Solvents Extraction
...Show More Authors

In this study two types of extraction solvents were used to extract the undesirable polyaromatics, the first solvent was furfural which was used today in the Iraqi refineries and the second was NMP (N-methyl-2-pyrrolidone).
The studied effecting variables of extraction are extraction temperature ranged from 70 to 110°C and solvent to oil ratio in the range from 1:1 to 4:1.
The results of this investigation show that the viscosity index of mixed-medium lubricating oil fraction increases with increasing extraction temperature and reaches 107.82 for NMP extraction at extraction temperature 110°C and solvent to oil ratio 4:1, while the viscosity index reaches to 101 for furfural extraction at the same extraction temperature and same

... Show More
View Publication Preview PDF
Publication Date
Mon Jul 28 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Oral health status, salivary physical properties and salivary Mutans Streptococci among a group of mouth breathing patients in comparison to nose breathing
...Show More Authors

Background: Mouth breathing can lead to introduce cold, dry unprepared air that insults the tissue of oral cavity, nasopharynx and lung, leading in turn to pathological changes in oronasal cavity, nasopharyngeal and other respiratory tissue, mouth breathing associated with nasal obstruction may lead to many health problems, in particular oral health problems such as inflammation of gingiva, oral dryness, change in oral environment that may decrease pH, salivary flow rate and increase bacteria and dental caries.Aims of the present study were to assess the oral health condition among mouth breather associated with nasal obstruction, including dental caries, oral cleanliness and gingival health condition as well as to evaluate the changes in s

... Show More
View Publication Preview PDF
Publication Date
Wed Dec 30 2009
Journal Name
Iraqi Journal Of Physics
The Effect of PVC Powder content on the Elastic Moduli and Acoustic Impedance of Epoxy Composites
...Show More Authors

The primary purpose of the present research was to study the effect of polyvinyl chloride (PVC) powder content on ultrasonic wave velocity in PVC/Epoxy composites. The second part is concerned with the relations of dynamic elastic moduli with the ultrasonic wave velocities, to determine how ultrasonic waves can affect them.
Experimental data have been obtained using the sonic viewer (model -5217 A) device to generate two types of waves, longitudinal waves of frequency 63 kHz and transverse waves of frequency 33 kHz and to measure the transit time required for those waves to travel through individual sample.
The experimental results have shown that the propagation of the ultrasonic velocity increases directly with PVC content in the

... Show More
View Publication Preview PDF
Publication Date
Tue Mar 01 2016
Journal Name
Journal Of Baghdad College Of Dentistry
A Comparison of the Effectiveness of Reciprocating System with Continuous Rotary Systems in Non-Surgical Endodontic Retreatment
...Show More Authors

Background: Optimal root canal retreatment was required safe and efficient removal of filling material from root canal. The aim of this in vitro study was to compare the efficacy of reciprocating and continuous motion of four retreatment systems in removal of root canal filling material. Materials and Methods: Forty distal roots of the mandibular first molars teeth were used in this study, these roots were embedded in cold clear acrylic,roots were instrumented using crown down technique and rotary ProTaper systemize Sx to size F2 ,instrumentation were done with copiousirrigation of 2.5% sodium hypochlorite and 17% buffered solution of EDTA was used as final irrigant followed by distilledwater, roots were obturated with AH26 sealer and Prota

... Show More
Preview PDF
Publication Date
Tue Mar 01 2022
Journal Name
Iraqi Journal Of Physics
Preparation, Characterization, and Antimicrobial Activity of Polyaniline and Fe2O3/Polyaniline Composite Nanoparticle
...Show More Authors

An oxidative polymerization approach was used to create polyaniline (PANI) and Fe2O3 /PANI nanoparticle combination. Various characterization approaches were used to investigate the structural, morphological, and Fe2O3 /PANI nanoparticle structures. The findings support the synthesis of polycrystalline nanoparticle PANI and Fe2O3 /PANI spherical nanoparticle composites. Gram-positive bacteria are tested for antibacterial activity. Various quantities of Nanoparticles of PANI and Fe2O3 /PANI nanoparticle composites were used to test Staph-aureus and gram-negative bacteria, E-coli, and candida species. PANI has antibacterial properties against all microo

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Mon Mar 01 2010
Journal Name
Journal Of Economics And Administrative Sciences
The study of the effect of the use of programming in the linear programming model (applied study)
...Show More Authors

The parametric programming considered as type of sensitivity analysis. In this research concerning to study the effect of the variations on linear programming model (objective function coefficients and right hand side) on the optimal solution. To determine the parameter (θ) value (-5≤ θ ≤5).Whereas the result، the objective function equal  zero and the decision variables are non basic، when the parameter (θ = -5).The objective function value increases when the parameter (θ= 5) and the decision variables are basic، with the except of X24, X34.Whenever the parameter value increase, the objectiv

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Nov 02 2014
Journal Name
Autophagy
Autophagy in osteoblasts is involved in mineralization and bone homeostasis
...Show More Authors

View Publication
Scopus (351)
Crossref (333)
Scopus Clarivate Crossref
Publication Date
Thu Nov 08 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
Studying the Effect of Different Separating Medium on the Roughness of the tissue surface of Acrylic Denture Base (In Vitro Study)
...Show More Authors

Objective: In order to evaluate the effect of different typed of Separating Medium on the roughness of the fitted
tissue surface of acrylic denture base.
Methodology: Chosen three types of separating medium (Group A Tin foil), (Group B Detery Isolant),(Group C
Cold Mould Seal),used 30 samples of hot cure acrylic resin ,10 samples for each group, after complete curing of
these samples , Profilometer device was used to measure the surface roughness of each sample in all groups.
Results: Using One Way ANOVA Test and LSD test, the results were highly significant in differences among all
groups. Although (Group A) showing lest roughness, (Group B) showing a satisfactory result of roughness, While
(Group C) Showing the hig