Preferred Language
Articles
/
jkmc-31
Clinical and experimental Study to evaluate the effect of Biphasic calcium phosphate collagen composite (cpcc) on healing of bone defects after oral surgical procedures
...Show More Authors

Background: A recent discoveries used for reconstruction in maxillofacial surgery is the composite bone graft materials. The availability of collagen I matrix make our choice to use this material in surgery .It is biomaterials that its structure could be modified by simple techniques. Studies to find a new materials use for bone reconstruction is to overcome the disadvantages of autogenous bone and the synthetic resorbable bone substitutes.

Objectives: This study was done to evaluate the effect of biphasic calcium phosphate collagen composite (ccpc) on healing of bone defects after oral surgical procedures.

Type of the study: A cross sectional study.

Method: It involved 60 patients, 35 male and 25 female, age (15-40) yearsand experimental animals study involved sixty rabbits.The study was done in Department of Maxillofacial surgery in Al anbarCollege of Dentistry (2015-2016).These patients were received tooth extraction, and other minor surgical procedures .Clinical and radiographical examination and patients consents are done before surgery. The surgery was done under local anesthesia.The resulting bone cavities are filled with composite bone graft material composed from combination of lyophilized hydrolysed collagen sponge (Hemospon),Brasil and Osteon II bone graft material,Korea .The area is closed with 3/0 block silk suture .Antibiotic cover (Ampicillin 500mg ×4) for 1 week was prescribed. The patients were followed up by careful clinical examination with radiograph 15-30 days after surgery. .Sixty New Zeleandi White rabbit were used in our study for histopathologicalexamination.Intraperitoneal injection of ketamine 10 mg with XYL-M2 solution 20 mg xylazine base used to anesthetize the animals. (5mm diameter) bone defects were made using straight surgical hand piece and bur in anterior mandibular region and filled with each material.  The study design involve the following groups: group 1( involve 15 rabbit; the defect was made and filled with blood clot only (control group),group 2( involve 15 rabbit, the defect was made and filled with collagen sponge only),group 3(Involve 15 rabbit, the defect was made and filled with Osteon II bone graft only),group4( involve 15 rabbit, the defect was made and filled with Osteon II bone graft +collagen (Composite bone graft).The flap were closed 3/0 black silk suture. The rabbits were killed after 30 days. 10 cmexcisional biopsy specimen was taken from the paramandibular area and placed in 10%formalin then send histopathologicalexamination.

Results:  Clinically, the treated area show good healing with absence of infection .Radiographs during follow up period show radiopacity indicating new bone formation .The results of experimental animals (Rabbits) indicategrowth new bone . In group 1 and group2, the center of the defects was depressed by surrounding tissues  Eung et al, While, in group 3&group 4, the graft materials maintained the space and the center of the defect did not depress. Statistical analysis indicates that during 4 th week ,the highest healing % is (100%) in group 3 &group4 in compared to control group (50%)..A significant difference in healing % was found among the treated groups.

Conclusion:The result indicates that biphasic calcium phosphate collagen composite can be efficiently utilized clinically.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Jul 02 2006
Journal Name
Journal Of The Faculty Of Medicine Baghdad
a placebo control study of the effect of nigella sativa fixed oil on the healing rate of recurrent aphthous ulceration
...Show More Authors

Background:

View Publication Preview PDF
Crossref
Publication Date
Wed Mar 29 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
The Effect of Orally -Administered Calcium Carbonate to Pregnant Women with Mild Pre-eclampsia
...Show More Authors

Pre-eclampsia is the most common medical complication of pregnancy associated with increased maternal and infant mortality and morbidity. Its exact etiology is not known, although several evidences indicate that various elements might play an important role in pre-eclampsia. This study was carried out to analyze and to compare the concentration of calcium, in mild pre-eclampsia and in normal pregnant women , and to determine the effect of oral supplementation with calcium on mild pre-eclampsia  , and whether this effect is related to the change in the level of serum calcium. Forty- five women  in the third trimester of pregnancy were selected to participate in this study and divided  into: fifteen apparently healthy, normo

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Mar 26 2019
Journal Name
Iraqi Journal Of Science
Study the Effect Some of Electrodeposition Parameters on Wear Resistance for Cu-MWCNT Composite Coating
...Show More Authors

A Copper- Mullet walled Carbon Nanotube Cu/MWCNT composite coatings prepared by direct and pulse electrodeposition with various contents of MWCNT particles, using electrodeposition method from acidic sulfate bath. The effect of the current density, pulse frequency and  particle loading (PL) of MWCNT particle in the electrolyte on the morphology and volume fraction Vol% of MWCNT in deposit were investigate. The experimental results indicated that the depositing condition affect on the microstructure of deposited copper and MWCNT Vol% in deposit. Also, the Vol% of MWCNT increases in deposit with particle loading (PL) increasing in the bath and increased with increased current density. Increasing MWCNTs in electrolyte produced increase

... Show More
View Publication Preview PDF
Publication Date
Thu Dec 26 2024
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of thermocycling on microleakage analysis of bulk filled base composite in comparison to incrementally placed nanohybrid composite in class II MOD restorations (An in vitro study)
...Show More Authors

Background: The study aim was to evaluate thermocycling effect on microleakage of occlusal and cervical margins of MOD cavity filled with bulk filled composites in comparison to incrementally placed nanohybrid composite and to evaluate the difference in microleakage between enamel and dentin margins for the three materials groups. Materials and method: Forty eight maxillary first premolars were prepared with MOD cavities. Samples were divided into three groups of sixteen teeth according to material used: Grandio: Grandio. SDR: SDR +Grandio. X-tra: X-tra base + Grandio. Each group was subdivided into two according to be thermocycled or not. After 24 hrs immersion in 2% methylene blue, samples weresectioned and microleakage was estimated. Res

... Show More
View Publication Preview PDF
Publication Date
Thu Apr 13 2023
Journal Name
Sustainability
Experimental Study of the Effect of Tack Coats on Interlayer Bond Strength of Pavement
...Show More Authors

The performance and lifetime of the flexible asphalt pavement are mainly dependent on the interfacial bond strength between layer courses. To enhance the bond between layers, adhesive materials, such as tack coats, are used. The tack coat itself is a bituminous material, which is applied on an existing relatively non-absorbent surface to ensure a strong bond between the old and newly paved layer. The primary objective of this study was to evaluate the effects of various types of tack coat materials on interlayer bond strength and to determine the optimal application rate for each type. The tack coat types used in this paper were RC-70, RC-250, and CSS-1h. Both laboratory-prepared and field-constructed hot mix asphalt concrete pavements usin

... Show More
View Publication
Scopus (2)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Sun Mar 01 2020
Journal Name
Iraqi Journal Of Physics
Optimization Procedures using Effect of Etalon Finesse and Driving Term on Optical Bistability
...Show More Authors

        In this work, analytical study for simulating a Fabry-Perot bistable etalon (F-P cavity) filled with a dispersive optimized nonlinear optical material (Kerr type) such as semiconductors Indium Antimonide (InSb). Because of a trade off between the etalon finesse values and driving terms, an optimization procedures have been done on the InSb etalon/CO laser parameters, using critical switching irradiance (Ic) via simulation systems of optimization procedures of optical cavity. in order to achieve the  minimum switching power and faster switching time, the optimization parameters of the finesse values and driving terms on optical bistability and switching dynamics must be studied.

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Dec 26 2024
Journal Name
Journal Of Baghdad College Of Dentistry
A comparative study to evaluate the shear bond strength of different resin sealers to dentin (An in vitro study)
...Show More Authors

Background: One of the major problems in endodontics is micro-leakage of root canal fillings which might contribute to the failure of endodontic treatment. To avoid this problem, a variety of sealers have been tested. The objective of this, in vitro, study was to evaluate the shear bond strength of four resin based sealers (AH plus, silver free AH26, RealSeal SE and Perma Evolution permanent root canal filling material) to dentin. Materials and Methods: Forty non-carious extracted lower premolars were used. The 2mm of the occlusal surfaces of teeth were sectioned, to expose the dentin surface. The exposed dentin surfaces of teeth were washed with 5ml of 2.5% NaOCl solution followed by 5ml of 17 % EDTA then rinsed by deionized water to remov

... Show More
View Publication Preview PDF
Publication Date
Mon Mar 01 2021
Journal Name
Al-khwarizmi Engineering Journal
Experimental Study of the Influence of Nanoparticles Additive to Diesel Fuel on the Emission Characteristics
...Show More Authors

The present experimental work is conducted to examine the influence of adding Alumina (Al2O3) nanoparticles and Titanium oxide (TiO2) nanoparticles each alone to diesel fuel on the characteristic of the emissions. The size of both Alumina and Titanium oxide nanoparticles which have been added to diesel fuel to obtain nano-fuel is about 20 nm and 25 nm respectively. Three doses of (Al2O3) and (TiO2) were prepared (25, 50, and 100) ppm. The nanoparticles mixed with gas oil fuel by mechanical homogenous (manual electrical mixer) and ultrasonic processor. The study reveals that the adding of Aluminum oxide (Al2O3) and Titanium oxide (TiO2) to g

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Sep 06 2018
Journal Name
Al-khwarizmi Engineering Journal
Bone Defect Animal Model for Hybrid Polymer Matrix Nano Composite as Bone Substitute Biomaterials
...Show More Authors

Addition of bioactive materials such as Titanium oxide (TiO2), and incorporation of bio inert ceramic such as alumina (Al2O3), into polyetheretherketone (PEEK) has been adopted as an effective approach to improve bone-implant interfaces. In this paper, hot pressing technique has been adopted as a production method. This technique gave a homogenous distribution of the additive materials in the proposed composite biomaterial. Different compositions and compounding temperatures have been applied to all samples. Mechanical properties and animal model have been studied in all different production conditions. The results of these new TiO2/Al2O3/PEEK biocomposites with different

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Jan 01 2015
Journal Name
Journal Of Engineering
Experimental Study of the effect of closed cavity wall on buildings cooling loads saving
...Show More Authors

The experimental study showed the use of closed cavity wall (the thickness of the cavity 5cm) made a percentage reduction in the cooling load caused by heat gain from the wall by (21.5 %) compared with the conventional wall. also the thermal resistance of the closed cavity was an average (0.2 m2.oC/W).

The experimental results of the study showed that the use of closed cavity wall reduced the average temperature of the inner surface of the wall during the day, and that the reduction was an average (0.45 oC)  when compared with the conventional wall , as well as the use of closed cavity wall reduced the temperature difference range of the inner surface of the wall during the day, and that the

... Show More
View Publication