Background: Thyroid surgery is most common endocrine surgery in general surgical practice. Objectives: the aim of this work is to evaluate the feasibility, benefits and outcomes of open mini-incision thyroidectomy and compared the results with that of conventional thyroidectomy. The comparison between the two groups was in term of incision length, amount of blood loss, time of operation, postoperative pain, hospital stay and the cosmetic outcomes.Type of the study: this is a single-blinded randomized controlled studyMethods: This study compared the advantages and outcomes of 22 patients subjected to mini-incision thyroidectomy (Group A) with the equal numbers of patients subjected to conventional thyroidectomy (Group B).Results: the operative time was statistically longer in minithyroidectomy than with conventional thyroidectomy. Postoperative pain score in the operative day and 24 hours postoperatively showed a significant difference in favor of mini-incision thyroidectomy. The cosmetic outcome and patients satisfaction was significantly and far better in minithyroidectomy group. The results between both groups were comparable regarding the postoperative complications. The hospital stay was shorter in the mini-incision group than in conventional group but the difference was not significant.Conclusions: mini-incision thyroidectomy is simple, safe and practical procedure that achieves the same results and the rate complications to the conventional thyroidectomy with less post operative pain and better aesthetic results. It is easily converted to conventional technique when necessary without added risks .
six specimens of the Hg0.5Pb0.5Ba2Ca2Cu3-y
This research examines the electrical, optical, and structural properties of zinc oxide (ZnO) and tin(IV) oxide (ZnO)1-x (SnO2)x composite thin films made by pulsed laser deposition, as well as the impact of composition concentration. The structural study of (ZnO)1-x (SnO2)x composites and thin films was conducted by X-ray analysis (XRD). Optical properties were investigated by UV–Vis infrared spectroscopy. The structural analysis revealed that all prepared thin-film composites were polycrystalline, exhibiting both hexagonal wurtzite and tetragonal phases for pure ZnO and SnO2, as well as a mixture of both phases for x=0.2 and 0.4. In contrast, the SnO2 phase was predominant for x=0.6 and 0.8. The increase in crystal size in the (
... Show MoreBackground This study aimed to evaluate the efficacy of once-daily liraglutide as an add-on to oral antidiabetics (OADs) on glycemic control and body weight in obese patients with inadequately controlled type 2 diabetes (T2D). Methods A total of 27 obese T2D patients who received 7 months (0.6 mg/day for the first month, 1.2 mg/day for 3 months, and 1.8 mg/day for 3 months) of liraglutide treatment as an add-on to OADs were included. Data on body weight (kg), fasting plasma glucose (FPG, mg/dL), postprandial glucose (PPG, mg/dL), and HbA1c (%), were recorded. Results Liraglutide doses of 1.2 mg/day and 1.8 mg/day were associated with significant decreases in body weight (by 8.0% and 11.9%, respectively, p < 0.01 for each) and HbA1c (by 20.0
... Show MoreThe present study is an attempt to throw light on the nature of the US policy regarding the Middle East region as portrayed by AI-Sabah, Al-Mashriq and Tariq Al-Shaab papers over a period of three months from 1st of July to 30th of September 2013.
In writing this study, a number of goals have been set by the researcher. These goals may include but in no way limited to the nature of the US image as carried by the above three papers, the nature of the topics tackled by them and the nature of the Arab countries which received more and extensive coverage than others.
A qualitative research approach is proposed for the study. This approach has allowed the researcher to arrive at definite answers for the possible questions rais
... Show MoreThe purpose of this research is to identify the youth issues in Talk Shows in the Iraqi satellite channels via monitoring a sample of episodes of the Talk Shows episodes which are concerned and analyzed the youth issues in the Iraqi satellite channels, namely, «Hala Shabab Program» at Al-Iraqia satellite Channel and «Shabab wa Banat Program» at Al-Sumaria satellite Channel by recording and re-watching them again. This research is classified as one of descriptive researches. The survey method was adopted in this study.
For this purpose, the researcher prepared an analysis form. The researcher de
... Show MoreCopper zinc tin sulfide selenide, Cu2 ZnSn(S1−x Se x)4 , absorbers are promising earth-abundant and environmentally benign materials for low-cost photovoltaic applications. This study investigates the structural and optical properties of Cu 2 ZnSn(S1−x Se x)4 nanostructured thin films prepared by pulsed laser deposition using melt-quenched targets with selenium compositions x = 0.0–1.0. X-ray diffraction revealed that films with low selenium content remained amorphous, whereas higher selenium incorporation promoted the formation of polycrystalline kesterite–stannite phases with preferred orientations along (112), (200), (220), and (312). The crystallite size increased from 12.3 to 17.9 nm as selenium reached x = 1.0, indicating enha
... Show MoreBackground: Recurrent laryngeal nerve injury is
an important post-thyroidectomy complication for
which different modalities of treatment were
practiced to lower its incidence.
Objectives: To estimate the incidence of
recurrent laryngeal nerve injury in thyroid surgeries
in relation to type of surgery, type of gland diseases
& nerve identification.
Methods: Different types of goiters prepared
preoperatively by indirect laryngoscopy, operated
upon with different types of surgeries, postoperative
direct laryngoscopy by the anaesthetist were done
and indirect laryngoscopy done as needed.
Results: Of of 200 patients, the overall incidence
of recurrent laryngeal nerve injury was 9
Patients (4.5%
Electrosurgery is the application of a high radio frequency of alternating polarity, electrical current to biological tissue as a means among many functions like cut, coagulate, desiccate, or fulgurate tissue in surgical practice . Many surgeons have faced during their lifetime one or more of the complications of these devices . It is either electrical, laser, ultrasonic and mechanical.