Preferred Language
Articles
/
jkmc-303
A Comparison of Sagittal Sections of Short T1inversion Recovery and T2 Weighted Fast Spin Echo Magnetic Resonance Sequences for Detection of Multiple Sclerosis Spinal Cord Lesions
...Show More Authors

Background: Multiple sclerosis is a chronic autoimmune inflammatory demyelinating disease of the central nervous system of unknown etiology. Different techniques and magnetic resonance image sequences are widely used and compared to each other to improve the detection of multiple sclerosis lesions in the spinal cord. Objective: To evaluate the ability of MRI short tau inversion recovery sequences in improvementof multiple sclerosis spinal cord lesion detection when compared to T2 weighted image sequences. Type of the study: A retrospective study. Methods: this study conducted from 15thAugust 2013 to 30thJune 2014 at Baghdad teaching hospital. 22 clinically definite MS patients with clinical features suggestive of spinal cord involvement, patients were imaged with sagittal short tau inversion recovery sequences and sagittal T2 weighted. Results: The mean age of the patients was 32.5 ± 6.7years; female to male ratio was 2.7:1. The total number of spinal cord MS lesions was 44 of them 86.4% in the cervical spine, 68.2%of the lesions had less than one vertebra extension,79.6% of the lesions did not show changes in the spinal cord morphology. There was a significant upgrading in the lesions conspicuity at short tau inversion recovery sequence comparing to T2 weighted image, P<0.001. A significant difference had been found in artifact grading between both sequences; P<0.001. Conclusions: short tau inversion recovery magnetic resonance image sequences improve detection of MS spinal cord plaques compared with T2 weighted image and itincreasesthe conspicuity of the visualized T2weighted image lesions, but also it accentuates theartifacts more than T2weighted image.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Jan 11 2025
Journal Name
Journal Of Engineering
Technological Analysis of Flat Surface Conditions by Magnetic Abrasive Finishing Method (MAF)
...Show More Authors

This study introduced the effect of using magnetic abrasive finishing method (MAF) for finishing flat surfaces. The results of experiment allow considering the MAF method as a perspective for finishing flat surfaces, forming optimum physical mechanical properties of surfaces layer, removing the defective layers and decreasing the height of micro irregularities. Study the characteristics which permit judgment parameters of surface quality after MAF method then comparative with grinding

View Publication
Publication Date
Mon Jan 01 2018
Journal Name
International Journal Of Surgery Open
Does preoperative magnetic resonant cholangiopancreatography (MRCP), improve the safety of laparoscopic cholecystectomy?
...Show More Authors

Publication Date
Mon Feb 18 2019
Journal Name
Iraqi Journal Of Physics
Anomaly in the earth magnetic field at north provinces of Najaf city
...Show More Authors

This paper investigated in the numerical simulation model to calculate the Earth magnetic field components at north provinces of Najaf city (Longitude 44.316 o -44.3592o E and Latitude 32.0508o - 32.0256o N). The components of the Earth magnetic field (total intensity (F), horizontal intensity (H), declination (D), inclination (I), the north component(X), the east component(Y), and Down component(Z)) were found by using spherical harmonic world magnetic model (WMM2010). A great deal of anomaly has been discovered in all components of the Earth magnetic field at the selected region (Long. 44.345o-44.335o E, Lat.32.042o-32.032o N) using Kriging method.

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Dec 30 2007
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Prevention of Scale Formation in Heat Exchanger Pipes by Using Magnetic Field
...Show More Authors

The possibility of using the magnetic field technique in prevention of forming scales in heat exchangers pipes using
hard water in heat transfer processes, also the studying the effective and controllable parameters on the mechanism of
scale formation.
The new designed heat exchanger experimental system was used after carrying out the basic process designs of the
system. This system was used to study the effect of the temperature (40-90 °C) and water flow rate (0.6-1.2 L/min) on
the total hardness with time as a function of precipitation of hardness salts from water and scale formation.
Different magnetic field designs in the heat exchanger experimental system were used to study the effect of magnetic
field design a

... Show More
View Publication Preview PDF
Publication Date
Wed Dec 26 2018
Journal Name
Iraqi Journal Of Science
Influence of the homogeneous magnetic field of the laser-induced breakdown spectroscopy of copper plasma
...Show More Authors

Copper plasma is generated with the existence of an external magnetic field and without its presence utilizing Nd:YAG laser (1064 nm ,9 ns) in different  pulse laser energy which ranges from(100 to 400) mJ in a vacuum. Plasma parameter beta ) is least than 1, this indicates that the existence of magnetic field confinement effect is proven. Note that both the electron temperature and electron density increases with the laser pulse energy increasing , Both are higher in the presence of a magnetic field.

View Publication Preview PDF
Publication Date
Tue Oct 11 2022
Journal Name
College Of Islamic Sciences
Hanbali's approach to building long and short travel provisions with issues attached to their provisions
...Show More Authors

 

The problem with research lies in hiding the Hanbali approach in building long and short travel provisions, as well as hiding some provisions relating to short travel that are not provided for by the jurists of Hanbali (in their books).

The research aims to demonstrate the approach and standards on which they based the long and short travel provisions, as well as to reflect the provisions of some of the issues that are silent on long and short travel, with evidence and significance.

The research included a preface and two researches, the researcher in the preface talked about the reality of long and short travel, in the first research on the approach of ha

... Show More
View Publication Preview PDF
Publication Date
Mon Apr 04 2022
Journal Name
Journal Of Educational And Psychological Researches
The Effect of Multiple Intelligences on the Acquisition of Science Operations by Middle School Students of Arabic Grammar
...Show More Authors

The current research aims to identify the multiple intelligences in the fourth students’ acquisition of the literary processes of Arabic grammar and to identify the differences in multiple intelligence according to gender (males - females). The study was determined for students of the fourth literary preparatory Al-Hakim Preparatory (for males) and Rabat Preparatory (for females) of the Second Karkh Education Directorate, topics from the Arabic grammar subject (past tense, present tense, imperative, subject, and object) for the first semester of the academic year 2019-2020. The results showed that there were no statistically significant differences at the significance level (0.05) between the average scores of the students who were tau

... Show More
View Publication Preview PDF
Publication Date
Mon Jan 01 2018
Journal Name
International Journal Of Innovation, Creativity And Change.
Multiple Intelligences and Their Relation to Blood Group Among University Students
...Show More Authors

Publication Date
Sat Jan 01 2022
Journal Name
Archives Of Civil Engineeringthis Link Is Disabled
Factors affecting time and cost trade-off in multiple construction projects
...Show More Authors

Scopus (3)
Scopus
Publication Date
Wed Nov 24 2021
Journal Name
Iraqi Journal Of Science
Comparison of Some Statistical Measurements Extracted From Benign, Malignant and Normal MRI Brain Images
...Show More Authors

People may believe that tissue of normal brain and brain with benign tumor
have the same statistical descriptive measurements that are significantly different
from the of brain with malignant tumor. Thirty brain tumor images were collected
from thirty patients with different complains (10 normal brain images, 10 images
with benign brain tumor and 10 images with malignant brain tumor). Pixel
intensities are significantly different for all three types of images and the F-test was
measured and found equal to 25.55 with p-value less than 0.0001. The means of
standard deviations and coefficients of variation showed that pixel intensities from
normal and benign tumors images are almost have the same behavior whereas the

... Show More
View Publication Preview PDF
Crossref