Background: Multiple sclerosis is a chronic autoimmune inflammatory demyelinating disease of the central nervous system of unknown etiology. Different techniques and magnetic resonance image sequences are widely used and compared to each other to improve the detection of multiple sclerosis lesions in the spinal cord. Objective: To evaluate the ability of MRI short tau inversion recovery sequences in improvementof multiple sclerosis spinal cord lesion detection when compared to T2 weighted image sequences. Type of the study: A retrospective study. Methods: this study conducted from 15thAugust 2013 to 30thJune 2014 at Baghdad teaching hospital. 22 clinically definite MS patients with clinical features suggestive of spinal cord involvement, patients were imaged with sagittal short tau inversion recovery sequences and sagittal T2 weighted. Results: The mean age of the patients was 32.5 ± 6.7years; female to male ratio was 2.7:1. The total number of spinal cord MS lesions was 44 of them 86.4% in the cervical spine, 68.2%of the lesions had less than one vertebra extension,79.6% of the lesions did not show changes in the spinal cord morphology. There was a significant upgrading in the lesions conspicuity at short tau inversion recovery sequence comparing to T2 weighted image, P<0.001. A significant difference had been found in artifact grading between both sequences; P<0.001. Conclusions: short tau inversion recovery magnetic resonance image sequences improve detection of MS spinal cord plaques compared with T2 weighted image and itincreasesthe conspicuity of the visualized T2weighted image lesions, but also it accentuates theartifacts more than T2weighted image.
AN Salih, LO Hamza, Ann. For. Res, 2022 - Cited by 2
Magneto-rheological (MR) Valve is one of the devices generally used to control the speed of Hydraulic actuator using MR fluid. The performance of valve depends on the magnetic circuit design. Present study deals with a new design of MR valve. The finite element analysis is carried out on this valve to optimize its design. The design of the magnetic circuit is accomplished by magnetic finite element software such as Finite Element Method Magnetic (FEMM). The Model dimensions of MR valve, material properties and the circuit properties of valve coil are taken into account. The results of analysis are presented in terms of magnetic strength and magnetic flux density. The valve can be operated with variable flow rate by varying the current. It i
... Show MoreIn recent years, the need for Machine Translation (MT) has grown, especially for translating legal contracts between languages like Arabic and English. This study primarily investigates whether Google Translator can adequately replace human translation for legal documents. Utilizing a widely popular free web-based tool, Google Translate, the research method involved translating six segments from various legal contracts into Arabic and assessing the translations for lexical and syntactic accuracy. The findings show that although Google Translate can quickly produce English-Arabic translations, it falls short compared to professional translators, especially with complex legal terms and syntax. Errors can be categorized into: polysemy,
... Show MoreAl-Yaqubi was biased in favor of Shia. May be du to his choice of source, materials. All historians as with other human beings are biased in their attitudes and preconceptions in one degree or another as well as in one direction or another.
The choice of source materials, their nature and the use made of them is an important index for measuring the achievement of ang historian.
Several specific questions arise. What sources did author use that were either unknown to or were not employed by his predecessors and contemporaries for whatever reason?
What sources are common to al- Yaqubi and his colleagues among the early Arab historians and what evidence of tendentiousness can be ascert- ained in these? To what extent can the author
Due to their attractive properties, silver nanowires (Ag-NWs) are newly used as nanoelectrodes in continuous wave (CW) THz photomixer. However, since these nanowires have small contact area, the nanowires fill factor in the photomixer active region is low, which leads to reduce the nanowires conductivity. In this work, we proposed to add graphene nanoantenna array as nanoelectrodes to the silver nanowires-based photomixer to improve the conductivity. In addition, the graphene nanoantenna array and the silver nanowires form new hybrid nanoelectrodes for the CW-THz photomixer leading to improve the device conversion efficiency by the plasmonic effect. Two types of graphene nanoantenna array are proposed in two separate photomixer conf
... Show MoreThe stanza in the sonnet has been defined as a set of poetic lines followed after proem
and be the same meter as that of proem in complete stanza, but in rhyme scheme different
from that meter. The couplet is defined as set of poetic lines that followed the stanza and be as
the same meter as that of stanza, but with different rhyme scheme. This definition is approved
by all specialized in field of Andalus literature and it was also proven to them that this
construction emptied of indications. This meter has endeavored to prove that that there were a
difference in denotation for meaning between the stanza and couplet. Thus, the sonneteers
have outweighed the sonnet of the blind "Tutaili" to their sonnets as they felt