Background: Avascular necrosis (AVN) is defined as cellular death of bone components due to interruption of the blood supply; the bone structures then collapse, resulting in bone destruction, pain, and loss of joint function. AVN is associated with numerous conditions and usually involves the epiphysis of long bones, such as the femoral head. In clinical practice, AVN is most commonly encountered in the hip. Early diagnosis and appropriate intervention can delay the need for joint replacement. However, most patients present late in the disease course. Without treatment, the process is almost always progressive, leading to joint destruction within 5 years.Treatment of a vascular necrosis depends mainly on early diagnosis which mainly based on clinical findings, x-ray finding & MRI.A variety of non vascularized bone grafting techniques have been proposed with varying degrees of success as treatment alternatives for osteonecrosis of the femoral head. The success of these procedures may be enhanced using ancillary growth and differentiation factors. Objectives: To treat non traumatic hip osteonecrosis by non vascularized bone graft versus core decompression. Type of the study: A retrospective study. Methods: We retrospectively reviewed 72 patients (88 hips) with osteonecrosis of the femoral head between May 2009, and March 2014,divided into two groups . Group A include 34 patients (44 hips) with osteonecrosis of the femoral head who had non vascularized bone grafting procedures done for them . Minimum follow-up was 12 months. We compared the outcomes in this cohort to similar hip number (44 hips) in 40 patients treated with core decompression only (group B). We used Phemister technique to make a window at the posterior aspect of greater trochanter to remove necrotic bone and packed the excavated area with autogenous cancellous bone graft taken from ipsilateral iliac crest or leave it without bone graft (decompression only). Results: We report the result of treatment for femoral head avascular necrosis depending on Ficat classification stage I, II, & III. The minimum follow up was 12 months (12m-36m). The success percentage of hips in our cohort of patients with non vascularized bone grafting group A are 86% (38 of 44 hips), which is higher than group B 63% (28 of 44 hips) with core decompression alone. Conclusions: These procedures core decompression and autogenous cancellous bone graft may defer joint arthroplasty in selected patients & it is more effective than core decompression alone in treating early stages of femoral head osteonecrosis.
Ultraviolet photodetectors have been widely utilized in several applications, such as advanced communication, ozone sensing, air purification, flame detection, etc. Gallium nitride and its compound semiconductors have been promising candidates in photodetection applications. Unlike polar gallium nitride-based optoelectronics, non-polar gallium nitride-based optoelectronics have gained huge attention due to the piezoelectric and spontaneous polarization effect–induced quantum confined-stark effect being eliminated. In turn, non-polar gallium nitride-based photodetectors portray higher efficiency and faster response compared to the polar growth direction. To date, however, a systematic literature review of non-polar gallium nitride-
... Show MoreThe American vision of the Non-governmental Organizations in Iraq the topic area of that’s paper dealing with Civil Society as concept and practice, its already consider as Western concept and associated with liberalism and political development, they are many definitions of its but most significantly is all organizations, agencies, trade unions and non-governmental institutions, that’s agencies were established after 2003 and received funds from United States and UN development agencies. The non- governments organizations played a significant role as support and develop many cultural, healthy, educational, and social projects, also that’s organizations try to reduction the effects of terrorists actions especially after ISI
... Show MoreIn this paper, a self-tuning adaptive neural controller strategy for unknown nonlinear system is presented. The system considered is described by an unknown NARMA-L2 model and a feedforward neural network is used to learn the model with two stages. The first stage is learned off-line with two configuration serial-parallel model & parallel model to ensure that model output is equal to actual output of the system & to find the jacobain of the system. Which appears to be of critical importance parameter as it is used for the feedback controller and the second stage is learned on-line to modify the weights of the model in order to control the variable parameters that will occur to the system. A back propagation neural network is appl
... Show MoreNon-thermal argon plasma needle at atmospheric pressure was
constructed. The experimental setup was based on a simple and low
cost electric component that generates a sufficiently high electric
field at the electrodes to ionize the argon gas which flow at
atmospheric pressure. A high AC power supply was used with 1.1
kV and 19.57 kHz. Non-thermal Argon plasma used on blood
samples to show the ability of non-thermal plasma to promote blood
coagulation. Three tests have been done to show the ability of plasma
to coagulate both normal and anti-coagulant blood. Each blood
sample has been treated for varying time from 20sec. to 180sec. at
different distances. The results of the current study showed that the
co
A numerical study of the two-dimensional steady free convection flow in an inclined annulus between two concentric square cavities filled with a porous medium is presented in this paper for the case when the side outer walls are kept with differentially heated temperature while the horizontal outer walls and the inner walls are insulated. The heated wall is assumed to have spatial sinusoidal temperature variation about a constant mean value. The Darcy model is used and the fluid is assumed to be a standard Boussinesq fluid. For the Cartesian coordinate system, the governing equations which were used in stream function form are discretized by using the finite difference method with successive under – relaxation method (SUR) and are solv
... Show MoreComposite materials are widely used in the engineered assets as aerospace structures, marine and air navigation owing to their high strength/weight ratios. Detection and identification of damage in the composite structures are considered as an important part of monitoring and repairing of structural systems during the service to avoid instantaneous failure. Effective cost and reliability are essential during the process of detecting. The Lamb wave method is an effective and sensitive technique to tiny damage and can be applied for structural health monitoring using low energy sensors; it can provide good information about the condition of the structure during its operation by analyzing the propagation of the wave in the
... Show MoreBackground : Breast cancer is the most common cancer of
women. When breast cancer is detected and treated early,
the chances for survival are better. Surgery is the most
important treatment for non-metastatic breast cancer.
Al-Kindy Col Med J 2008 Vol.5(1) 40 Original Article
Objectives : The aim of this study is to review different
clinical presentation and to evaluate types of surgical
procedures and complications in treatment of nonmetastatic breast cancer.
Method : During the period from Jun 1998 to May 2005,
93 patients with non-metastatic breast cancer were
diagnosed and treated surgically in 2 hospitals in Baghdad (
Hammad Shihab military hospital and Al-Kindy teaching
hospital).
Results : Wo
Cold plasma is a relatively low temperature gas, so this feature enables us to use cold plasma to treat thermally sensitive materials including polymers and biologic tissues. In this research, the non-thermal plasma system is designed with diameter (3 mm, 10 mm) Argon at atmospheric pressure as well as to be suitable for use in medical and biotechnological applications.
The thermal description of this system was studied and we observed the effect of the diameter of the plasma needle on the plasma, when the plasma needle slot is increased the plasma temperature decrease, as well as the effect of the voltages applied to the temperature of the plasma, where the temperature increasing with increasing the applied voltage . Results showed t