Single Layer Extra-Mucosal Versus Double Layer Intestinal Anastomosis for Colostomy Closure: A Prospective Comparative Study
...Show More Authors

Background: The main objective was to compare the outcome of single layer interrupted extra-mucosal sutures with that of double layer suturing in the closure of colostomies.

Subjects and Methods: Sixty-seven patients with closure colostomy were assigned in a prospective randomized fashion into either single layer extra-mucosal anastomosis (Group A) or double layer anastomosis (Group B). Primary outcome measures included mean time taken for anastomosis, immediate postoperative complications, and mean duration of hospital stay. Secondary outcome measures assessed the postoperative return of bowel function, and the overall mean cost. Chi-square test and student t-test did the statistical analysis..

Results:  Thirty-two patients were allocated to group A and 35 patients to group B. The mean time taken for anastomosis was significantly shorter in group A (23.25 ± 1.20 min in group A vs. 36.71 ± 1.93 min in group B; P<0.001). A significant shorter duration of hospital stay was seen in group A (7.00 ± 1.778 days in group A vs. 9.74 ± 1.990 days in group B; P<0.001). The detection of bowel sound was substantially quicker in group A as compared to group B (4.56 ± 0.50 days in group A vs. 6.46±0.50 days in group B; P<0.001). There was no significant discrepancy between the two groups regarding anastomotic leak rates (P= 0.543). The mean cost of double layer intestinal anastomosis method was significantly higher than that of single layer anastomosis (P<0.001).

Conclusions: The use of single layer extra-mucosal anastomosis of the intestine has the advantage of taking less time, less morbidity and cost-effective to perform with the same rate of anastomotic leak in the closure of colostomy.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Mar 30 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Single Dose Antibiotic Prophylaxis in Outpatient Oral Surgery Comparative Study
...Show More Authors

         It is clear that correct application of antibiotic prophylaxis can reduce the incidence of infection  resulting from the bacterial  inoculation in a variety of clinical situations; it cannot   prevent  all  infections  any  more  than it  can   eliminate  all  established infections. Optimum  antibiotic   prophylaxis  depends on:  rational  selection  of the drug(s),  adequate  concentrations  of the  drug  in  the  tissues that  are at risk, and attention to  timing  of  administration.  Moreover,  the  risk  of

... Show More
View Publication Preview PDF
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Thu Mar 30 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn: 1683 - 3597 , E-issn : 2521 - 3512)
Single Dose Antibiotic Prophylaxis in Outpatient Oral Surgery Comparative Study
...Show More Authors

         It is clear that correct application of antibiotic prophylaxis can reduce the incidence of infection  resulting from the bacterial  inoculation in a variety of clinical situations; it cannot   prevent  all  infections  any  more  than it  can   eliminate  all  established infections. Optimum  antibiotic   prophylaxis  depends on:  rational  selection  of the drug(s),  adequate  concentrations  of the  drug  in  the  tissues that  are at risk, and attention to  timing  of  administration.  Moreover,  the  risk  of  infection  in  some situations  does not outweigh  the risks which  attend the administration of even the safest antibiotic drug. The aim of this study was to comp

... Show More
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Society Of Petroleum Engineering
Investigating geomechanical considerations on suitable layer selection for hydraulically fractured horizontal wells placement in tight reservoirs
...Show More Authors

Scopus (5)
Scopus
Publication Date
Fri Jul 01 2022
Journal Name
Iraqi Journal Of Science
Multi-layer Multi-objective Evolutionary Algorithm for Adjustable Range Set Covers Problem in Wireless Sensor Networks
...Show More Authors

Establishing complete and reliable coverage for a long time-span is a crucial issue in densely surveillance wireless sensor networks (WSNs). Many scheduling algorithms have been proposed to model the problem as a maximum disjoint set covers (DSC) problem. The goal of DSC based algorithms is to schedule sensors into several disjoint subsets. One subset is assigned to be active, whereas, all remaining subsets are set to sleep. An extension to the maximum disjoint set covers problem has also been addressed in literature to allow for more advance sensors to adjust their sensing range. The problem, then, is extended to finding maximum number of overlapped set covers. Unlike all related works which concern with the disc sensing model, the cont

... Show More
View Publication Preview PDF
Publication Date
Mon Jan 01 2024
Journal Name
Ieee Access
Dual-Layer Compressive Sensing Scheme Incorporating Adaptive Cross Approximation Algorithm for Solving Monostatic Electromagnetic Scattering Problems
...Show More Authors

View Publication
Scopus Clarivate Crossref
Publication Date
Wed Nov 11 2020
Journal Name
The Abu Dhabi International Petroleum Exhibition & Conference, Abu Dhabi, Uae, November 2020. Paper Number: Spe-203249-ms
Investigating Geomechanical Considerations on Suitable Layer Selection for Hydraulically Fractured Horizontal Wells Placement in Tight Reservoirs
...Show More Authors

The instant global trend towards developing tight reservoir is great; however, development can be very challenging due to stress and geomechanical properties effect in horizontal well placement and hydraulic fracturing design. Many parameters are known to be important to determine the suitable layer for locating horizontal well such as petrophysical and geomechanical properties. In the present study, permeability sensitivity to stress is also considered in the best layer selection for well placement. The permeability sensitivity to the stress of the layers was investigated using measurements of 27 core sample at different confining stress values. 1-D mechanical earth model (MEM) was built and converted to a 3-D full-field geomechanical mode

... Show More
View Publication
Publication Date
Sat Oct 01 2016
Journal Name
Journal Of Non-newtonian Fluid Mechanics
On the stability of the BEK family of rotating boundary-layer flows for power-law fluids
...Show More Authors

View Publication
Scopus (7)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Tue Apr 30 2019
Journal Name
International Journal Of Environmental Research
A Comparative Study for the Identification of Superior Biomass Facilitating Biosorption of Copper and Lead Ions: A Single Alga or a Mixture of Algae
...Show More Authors

View Publication
Scopus (12)
Crossref (12)
Scopus Clarivate Crossref
Publication Date
Mon Feb 25 2019
Journal Name
Iraqi Journal Of Physics
Comparison study of CC and CH vibration frequencies and eelectronic properties for mono, Di, Tri, and tetra-rings layer of arm chair (SWCNTs)
...Show More Authors

Semi-empirical methods were applied for calculating the vibration frequencies and IR absorption intensities for normal coordinates of the {mono (C56H28), di (C84H28), tri (C112H28) and tetra (C140H28)} -rings layer for (7,7) armchair single wall carbon nanotube at their equilibrium geometries which were all found to have D7d symmetry point group.

Assignment of the modes of vibration (3N-6) was done depending on the pictures of their modes by applying (Gaussian 03) program. Comparison of the vibration frequencies of (mono, di, tri and tetra) rings layer which are active in IR, and inactive in Ramman spectra. For C-H stretching vibrat

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon Jun 03 2019
Journal Name
Rawal Medical Journal
SUPERIOR VERSUS ANTERIOR PLATING OF MIDSHAFT CLAVICLE FRACTURE IN ADULT COMPARATIVE STUDY
...Show More Authors

Clavicle fractures are common injuries in young, active individuals. The majority of the fractures (80% to 85%) occur in the mid-shaft of the bone and account for approximately 2.6% of all fractures. For many years the standard treatment of fracture clavicle was the "figure-of-eight" bandage but several indications for operative fixation, the position of plate fixation for clavicle fracture remains controversial. The aim of this study is to compare between anterio—inferior and anterior-superior plating of mid-shaft displaced clavicle fracture in complications, plate prominence, nonunion, malunion and range of motion. This study is a prospective study conducted in Al-Kindy teaching hospital .A total of 30 patients with fracture mid –sh

... Show More
View Publication Preview PDF