Preferred Language
Articles
/
jkmc-274
Single Layer Extra-Mucosal Versus Double Layer Intestinal Anastomosis for Colostomy Closure: A Prospective Comparative Study
...Show More Authors

Background: The main objective was to compare the outcome of single layer interrupted extra-mucosal sutures with that of double layer suturing in the closure of colostomies.

Subjects and Methods: Sixty-seven patients with closure colostomy were assigned in a prospective randomized fashion into either single layer extra-mucosal anastomosis (Group A) or double layer anastomosis (Group B). Primary outcome measures included mean time taken for anastomosis, immediate postoperative complications, and mean duration of hospital stay. Secondary outcome measures assessed the postoperative return of bowel function, and the overall mean cost. Chi-square test and student t-test did the statistical analysis..

Results:  Thirty-two patients were allocated to group A and 35 patients to group B. The mean time taken for anastomosis was significantly shorter in group A (23.25 ± 1.20 min in group A vs. 36.71 ± 1.93 min in group B; P<0.001). A significant shorter duration of hospital stay was seen in group A (7.00 ± 1.778 days in group A vs. 9.74 ± 1.990 days in group B; P<0.001). The detection of bowel sound was substantially quicker in group A as compared to group B (4.56 ± 0.50 days in group A vs. 6.46±0.50 days in group B; P<0.001). There was no significant discrepancy between the two groups regarding anastomotic leak rates (P= 0.543). The mean cost of double layer intestinal anastomosis method was significantly higher than that of single layer anastomosis (P<0.001).

Conclusions: The use of single layer extra-mucosal anastomosis of the intestine has the advantage of taking less time, less morbidity and cost-effective to perform with the same rate of anastomotic leak in the closure of colostomy.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Jan 01 2015
Journal Name
Journal Of Engineering
Shell and Double Concentric Tube Heat Exchanger Calculations and Analysis
...Show More Authors

This study concerns a new type of heat exchangers, which is that of shell-and-double concentric tube heat exchangers. The case studies include both design calculations and performance calculations.

       The new heat exchanger design was conducted according to Kern method. The volumetric flow rates were 3.6 m3/h and 7.63 m3/h for the hot oil and water respectively. The experimental parameters studied were: temperature, flow rate of hot oil, flow rate of cold water and pressure drop.

A comparison was made for the theoretical and experimental results and it was found that the percentage error for the hot oil outlet temperature was (- 1.6%). The percentage

... Show More
View Publication
Publication Date
Wed Jun 01 2016
Journal Name
Journal Of Engineering
Entropy Generation of Shell and Double Concentric Tubes Heat Exchanger
...Show More Authors

Entropy generation was studied for new type of heat exchanger (shell and double concentric tubes heat exchanger). Parameters of hot oil flow rate, temperature of inlet hot oil and pressure drop were investigated with the concept of entropy generation. The results showed that the value of entropy generation increased with increasing the flow rate of hot oil and when cold water flow rate was doubled from 20 to 40 l/min, these values were larger. On the other hand, entropy generation increased with increasing the hot oil inlet temperature at a certain flow rate of hot oil. Furthermore, at a certain hot oil inlet temperature, the entropy generation increased with the pressure drop at different hot oil inlet flow rates. Final

... Show More
View Publication Preview PDF
Publication Date
Thu Jun 30 2016
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Entransy Dissipation of Shell and Double Concentric Tubes Heat Exchanger
...Show More Authors

The concept of entransy dissipation was determined for new type of heat exchanger (shell and double concentric tubes heat exchanger). Three parameters, hot oil flow rate, temperature of inlet hot oil and pressure drop of system were investigated with this concept (entransy dissipation). The results showed that the value of entransy dissipation of oil and of system which represents the summation of entransy dissipation of both oil and water increased with increasing the flow rate of hot oil and these values were larger when cold water flow rate was doubled. Also they were increased with increasing the hot oil inlet temperature at a certain flow rate of hot oil. Furthermore, the pressure drops for hot oil in both shell side and inner tubes

... Show More
View Publication Preview PDF
Publication Date
Tue Mar 16 2021
Journal Name
2021 4th International Conference On Energy Conservation And Efficiency (icece)
Finite Element Modeling Of Finned Double-Pass Solar Air Heaters
...Show More Authors

View Publication
Scopus (4)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Sun Jan 02 2011
Journal Name
Education College Journal/al-mustansiriyah
Double Stage Shrinkage Estimators of Two Parameters Generalized Rayleigh Distribution
...Show More Authors

Publication Date
Sat Jan 01 2022
Journal Name
Materials Today: Proceedings
Comparative study between the individual, dual and triple addition of (SF), (TGP) and (PVA) for improving Local Plaster of Paris (LPOP) properties
...Show More Authors

View Publication
Scopus (8)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Fri May 16 2025
Journal Name
Tikrit Journal Of Engineering Sciences
Comparative Study of Activated Carbon and Silver Nanoparticle-Loaded Activated Carbon Derived from Tea Waste for Removal of Tetracycline from Aqueous Solution
...Show More Authors

The present work elucidates the utilization of activated carbon (AC) and activated carbon loaded with silver nanoparticles (AgNPs-AC) to remove tetracycline (TC) from synthetically polluted water. The activated carbon was prepared from tea residue and loaded with silver nanoparticles. Scanning electron microscopy (SEM), X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FTIR), and Brunauer-Emmett-Teller (BET) were used to characterize the activated carbon (AC) and silver nanoparticles-loaded activated carbon (AgNPs-AC). The impact of various parameters on the adsorption effectiveness of TC was examined. These variables were the initial adsorbate concentration (Co), solution acidity (pH), adsorption time (t), and dosag

... Show More
View Publication
Scopus Crossref
Publication Date
Mon Jun 30 2025
Journal Name
Iraqi Journal Of Science
Hormonal and biochemical factors among chronic liver disease men infected with Toxoplasmosis and some protozoan intestinal parasites
...Show More Authors

Chronic liver disease (CLD) can potentially cause disruptions in the normal functioning of various endocrine organs responsible for producing hormones. As a result, individuals suffering from CLD may experience fluctuations or imbalances in the levels of certain hormones within their bodies. As well as they frequently have suppressed immune systems making them more vulnerable to parasite infections. The primary objective of this study was to investigate the association between Toxoplasma gondii infections and liver function by analyzing the interplay between these parasites and hormones. This study was conducted in Baghdad, Iraq from December 2021 to May 2022. One hundred and twenty male patients with Chronic liver disease (CLD) (ag

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Tue Jun 30 2015
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Single Well Coning Problem and Applicable Solutions
...Show More Authors

One of the most important and common problems in petroleum engineering; reservoir, and production engineering is coning; either water or gas coning. Almost 75% of the drilled wells worldwide contains this problem, and in Iraq water coning problem is much wider than the gas coning problem thus in this paper we try to clarify most of the reasons causing water coning and some of applicable solutions to avoid it using the simulation program (CMG Builder) to build a single well model considering an Iraqi well in north of Iraq black oil field with a bottom water drive, Coning was decreased by 57% by dividing into sub-layers (8) layers rather than (4) layers, also it was decreased (Coning) by 45% when perforation numbers and positions was chang

... Show More
View Publication Preview PDF
Publication Date
Fri Mar 01 2024
Journal Name
Baghdad Science Journal
A Comparison between Ericson's Formulae Results and Experimental Data Using New Formulae of Single Particle Level Density
...Show More Authors

The partial level density PLD of pre-equilibrium reactions that are described by Ericson’s formula has been studied using different formulae of single particle level density . The parameter  was used from the equidistant spacing model (ESM) model and the non- equidistant spacing model (non-ESM) and another formula of  are derived from the relation between  and level density parameter . The formulae used to derive  are the Roher formula, Egidy formula, Yukawa formula, and Thomas –Fermi formula. The partial level density results that depend on  from the Thomas-Fermi formula show a good agreement with the experimental data.

View Publication Preview PDF
Scopus Crossref