Electrosurgery is the application of a high radio frequency of alternating polarity, electrical current to biological tissue as a means among many functions like cut, coagulate, desiccate, or fulgurate tissue in surgical practice . Many surgeons have faced during their lifetime one or more of the complications of these devices . It is either electrical, laser, ultrasonic and mechanical.
Polymers (Silicon elastomer) are used lately as a conductive material in electronic application in addition to be transparent, to light. In this paper we prepared polymer films about (1mm) thick and less which contain Ni-metal powder cured in magnetic vacuum furnaces at temperature 120°C in order to arrange or to be oriented the particles of the Ni- powder through the polymer in such a way to be conductive for electric currents. We found that these films are sensitive to any loads on the surface (force per unit area). Using light loads on a unit electric cell from these films, we get an electric transparent sensor that could be used in sensing applications.
Abstract
Electrical magnate was designed and constructed, the optimum Magnetic flux and the effect of time on the physical properties of the alkaline (magnetic water) produced from the bottled drinking water [the total dissolved solids (TDS) or the electrical conductivity, and pH] were studied, to simulate ZamZam water in Mekka Saudi Arabia. Also, the efficiency of magnetic field from this designed electrical magnate in decreasing the TDS of sea water (of 1500 ppm NaCl Content), to convert it to water suitable for irrigation (TDS<1000 ppm) was investigated in this work.The results show that the magnetic flux from our designed electrical magnate in the range of (0.013- 0.08) Tesla and 30 minut
... Show MoreBackground Median sternotomy is the gold standard incision for most cardiac operations. However, with the advent of minimal invasive surgery, a new approach emerged in cardiac surgery named mini-sternotomy and has been successfully used to perform a variety of operations.
The aim of this paper is to present our experience of using mini-sternotomy to harvest the left internal mammary artery (LIMA) for off-pump revascularization of the left anterior descending artery (LAD)
Methodology Over a 2-year period (October 2012-October 2014), 100 patients underwent coronary artery bypass grafting (CABG) via conventional median sternotomy (CMS) (n=80) and mini-sternotomy (MS) (n=20). The
... Show MoreA study carried out on ceramic material made at (a-Al2O3) doped with MgO (0.5 , 0.3 , 0.2,0.1)%,with particle size at 63mm.
A Hydraulic press of 5kn at diameter of 2cm.A nnalelling at 1500Co and 6 hrs still to see the effect on the changes of the dielectric material. With frequency range at (1K – 1M) Hz. And the result show that at percentage of 0.5% of MgO, the real dielectric material decreased with the increased frequency
Thin films of zinc selenide ZnSe have been prepared by using thermal evaporation method in vacuum with different thickness (1000 – 4000) Ao and a deposited on glass substrate and studying some electrical properties including the determination of A.C conductivity and real, imaginary parts of dielectric constant and tangent of loss angle. The result shows that increasing value of A.C conductivity with increasing thickness and temperature, and increasing capacitance value with increasing the temperature and decrease with increasing frequency . Real and imaginary parts of dielectric constant and tangent of loss angle decrease with increasing frequency
The research aims to identify the theoretical foundations for measuring and analyzing quality costs and continuous improvement, as well as measuring and analyzing quality costs for the Directorate of Electricity Supply / Middle Euphrates and continuous improvement of the distribution of electrical energy,The problem was represented by the high costs of failure and waste in electrical energy result to the excesses on the network and the missing (lost) energy,Thus, measuring and analyzing quality costs for the distribution of electrical energy and identifying continuous improvement leads to a reduction in missing and an increase in sales, as the research reached many conclusions, the most important of which is the high percentage o
... Show MoreIn this work, animal bones with different shapes and sizes were used to study the characteristics of the ground penetrating Radar system wares reflected by these bones. These bones were buried underground in different depths and surrounding media. The resulting data showed that the detection of buried bones with the GPR technology is highly dependent upon the surrounding media that the bones were buried in. Humidity is the main source of signal loss in such application because humidity results in low signal-to-noise ratio which leads to inability to distinguish between the signal reflected by bones from that reflected by the dopes in the media such as rock .
A 5-traverse 2D resistivity survey and 20 Vertical Electrical Sounding (VES) points were carried out on Ile Epo Dump Site with a view to inferring the extent of migration of leachate plumes in the subsurface for possible contamination of groundwater. The surveys were carried out with Omega model resistivity meter. The Schlumberger configuration was employed for the VES while Wenner configuration was employed for the 2D resistivity survey (Constant Separation Techniques). The obtained VES and CST data were interpreted using WinResist and DIPRO respectively. The integrated results revealed three to four geo-electrically polluted materials as highly saturated fills (15 Ωm, 1.9 – 27.4m), saturated fills (15 - 30 Ωm, 3.6 – 29.9m) and un
... Show MoreThe electrical insulation of the manufacture sulfonated phenol-formaldehyde viscous material (product) has been studied with Polyvinyl-acetate (PVA) and toluene diisocyanate (TDI) blend has been prepared by fixing percentage by weight 3:1 and mixed with different percentages by weight of the product sulfonated phenol formaldehyde viscous mass (SPF). The Fourier transform infrared (FTIR) spectroscopy is done on (SPF) resin powder and prepared film of PVA-TDI-SPF viscous mass. The quality factor (Q), dissipation factor (D), parallel resistance (Rp), series resistance (Rs), parallel capacitance (Cp), series capacitance (Cs) and phase shift (?) are measured. The calculated maximum dielectric constant (??) is 3.49x107 at sample (1) wt.1% SPF vis
... Show MoreChalcopyrite thin films were one-step potentiostatically deposited onto stainless steel plates from aqueous solution containing CuSO4, In2(SO4)3 and Na2S2O3.The ratio of (In3+:Cu2+) which involved in the solution and The effect of cathodic potentials on the structural had been studied. X-ray diffraction (XRD) patterns for deposited films showed that the suitable ratio of (In3+:Cu2+) =6:1, and suitable voltage is -0.90 V versus (Ag/AgCl) reference electrode