Preferred Language
Articles
/
jkmc-192
Comparison between the Use of bupivacaine 0.5%alone and bupivacaine 0.5% with nefopam 20mg in sciatic n block ( popliteal approach) and femoral n block in patients undergoing below knee surgery
...Show More Authors

Objective : Sciatic nerve block (popliteal approach) and femoral N block is a new technique other than general anesthesia in below knee surgery because it provides adequate muscle relaxation, with good intraoperative and post-operative analgesia. Nefopam is non opioid, non-respiratory depressant and non-sedative was mixed with local anesthetics drug to study the effects. This study was done to compare the onset and duration of sensory and onset time and duration of action of motor block following administration of either bupivacaine alone with administration of bupivacaine and Nefopam in patients undergoing below knee lower limb surgeries under ultrasound guided regional anesthesia.
Methods: 100 patients with American society of anesthesiologists (ASA) 2 / 3/4 patients between 25 and 85 years who underwent elective and emergency lower limb surgeries randomly allocated into two group, each group has 50 patients by a sealed envelope technique to receive 20 ml of 0.5% Bupivacaine with 2 ml of normal saline in Group BS and 20 ml of 0.5% Bupivacaine with 2ml (20mg) of Nefopam in the second group (Group BN). The onset time, duration time of both sensory and motor blocking were seen and compared between the two groups.
Results : The onset time of both sensory and motor blockade was shorter in Group BN (bupivacaine with nefopam) when compared to Group BS (bupivacaine and normal saline) (p<0.0001). The duration of both sensory and motor blockade was longer in Group BN when compared to Group BS (p<0.0001). There were no significant hemodynamic changes (PR, BP,SPO2) in both groups. Also there is no any side effect or any complication.
Conclusion Nefopam when mixed with Bupivacaine in Sciatic nerve block and femoral nerve block in below knee surgeries shortens the onset time and prolongs the duration of action of both sensory and motor blockade without any systemic side effects and give excellent intra and postoperative analgesia.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Mar 01 2020
Journal Name
Iop Conference Series: Materials Science And Engineering
Characterization of nickel oxide nanocatalyst electrodes for an alkaline fuel cell
...Show More Authors
Abstract<p>In this paper had been studied the characterization of the nanocatalyst (NiO) Mesh electrodes. For fuel cell. The catalyst is prepared and also the electrodes The structural were studied through the analysis of X-ray diffraction of the prepared nanocatalyst for determining the yielding phase and atomic force microscope to identify the roughness of prepared catalyst surface, Use has been nanocatalyst led to optimization of cell voltage, current densities & power for a fuel cell.</p>
View Publication
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Mon Oct 01 2018
Journal Name
Iraqi Journal Of Physics
Preparation single layer of (MgO) as antireflection coating using PLD technique
...Show More Authors

In this work preparation of antireflection coating with single layer of MgO using pulsed laser deposition (PLD) method which deposit on glass substrate with different thicknesses (90 and 100) nm annealed at temperature 500 K was done.
The optical and structural properties (X-ray diffraction) have been determined. The optical reflectance was computed with the aid of MATLAB over the visible and near infrared region. Results shows that the best result obtained for optical performance of AR'Cs at 700 shots with thickness 90 nm nanostructure single layer AR'Cs and low reflection at wavelength 550 nm.

View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Journal Of The Mechanical Behavior Of Materials
Performance of reinforced concrete non-prismatic beams having multiple openings configurations
...Show More Authors
Abstract<p>This experimental study demonstrates the gable-reinforced concrete beams’ behavior with several number of openings (six and eight) and posts’ inclination, aimed to find the strength reduction in this type of beam. The major results found are: for the openings extending over similar beam length it is better to increase the number of posts (openings), <italic>i.e.</italic>, increasing opening number led to decrease in opening area, which allows us to transmit stresses and act as lever arms between the upper and the lower chords. Also, findings revealed that the inclined posts have larger loading at the mid-point relative to vertical ones. For gables with vertical posts hav</p> ... Show More
View Publication Preview PDF
Scopus (6)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Sun Jun 30 2019
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Adsorption of Chromium Ions on Activated Carbon Produced from Cow Bones
...Show More Authors

Due to the broad range uses of chromium for industrial purposes, besides its carcinogenic effect, an efficient, cost effective removal method should be obtained. In this study, cow bones as a cheap raw material were utilized to produce active carbon (CBAC) by physiochemical activation, which was characterized using: SEM to investigate surface morphology and BET to estimate the specific surface area. The best surface area of CBAC was 595.9 m2/gm which was prepared at 600 C activation temperature and impregnation ratio of 1:1.5. CBAC was used in aqueous chromium ions adsorption. The investigated factors and their ranges are: initial concentration (10-50 mg/L), adsorption time (30-300 min), temperature (20-50

... Show More
View Publication Preview PDF
Crossref (10)
Crossref
Publication Date
Sun Jul 30 2023
Journal Name
Pakistan Heart Journal
Evaluation of nurses Practice toward Children Safety Post Cardiac Catheterization Procedure
...Show More Authors

Publication Date
Tue Mar 31 2015
Journal Name
Al-khwarizmi Engineering Journal
Intelligent H2/H∞ Robust Control of an Active Magnetic Bearings System
...Show More Authors

Abstract

Robust controller design requires a proper definition of uncertainty bounds. These uncertainty bounds are commonly selected randomly and conservatively for certain stability, without regard for controller performance.  This issue becomes critically important for multivariable systems with high nonlinearities, as in Active Magnetic Bearings (AMB) System. Flexibility and advanced learning abilities of intelligent techniques make them appealing for uncertainty estimation. The aim of this paper is to describe the development of robust H2/H controller for AMB based on intelligent estimation of uncertainty bounds using Adaptive Neuro Fuzzy Inference System (ANFIS).  Simulatio

... Show More
View Publication Preview PDF
Publication Date
Sun Sep 07 2008
Journal Name
Baghdad Science Journal
Variables Affecting Developments of Hydroxyapatite Coating by Using Electrophoretic Deposition Technique
...Show More Authors

Electrophoretic Deposition (EPD) process offers various advantages like the fabrication of the ceramic coatings and bodies with dense packing, good sinterability and homogenous microstructure. The variables namely (applied potential, deposition time and sintering temperature) affected the development of hydroxyapatite (HAP) coatings. The coating weight and thickness were found to increase with the increase in applied potential or coating time. Sintering temperature was found to affect in change phases of the metal, furthermore the firing shrinkage of the HAP coating on a constraining metal substrate leads to serve cracking. XRD Characterization indicates the formation of a contamination free phase pure, and the optical micrographs show th

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Dec 07 2018
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Novel Combination for Self-Nanoemulsifying Drug Delivery System of Candesartan Cilexetil
...Show More Authors

Solubility problem of many of effective pharmaceutical molecules are still one of the major obstacle in theformulation of such molecules. Candesartan cilexetil (CC) is angiotensin II receptor antagonist with very low water solubility and this result in low and variable bioavailability. Self- emulsifying drug delivery system (SEDDS) showed promising result in overcoming solubility problem of many drug molecules. CC was prepared as SEDDS by using novel combination of two surfactants (tween 80 and cremophore EL) and tetraglycol as cosurfactant, in addition to the use of triacetin as oil. Different tests were performed in order to confirm the stability of the final product which includes thermodynamic study, determination of self-emulsificat

... Show More
View Publication Preview PDF
Scopus (7)
Crossref (1)
Scopus Crossref
Publication Date
Thu Nov 08 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
Risk factor of urinary incontinence among menopausal women at Babylon city
...Show More Authors

Purpose: To identify the risk factors of urinary incontinency for menopausal women.
Methodology: A descriptive analytic study was conducted to identify the risk factor for urinary incontinency
and selected non-probability sample (purposive sample) from (200) menopausal women (45-65) who have
urinary incontinence as visitors and caregiver women who attend at Hila surgical teaching hospital during the
period 1/11/2010-30/3/2011. Questionnaire format used for data collection was designed and constructed
after reviewing related literatures and previous studies and consists of the following variables: Demographic
and reproductive characteristics of menopausal women who suffers from urinary incontinence
Results: The study

... Show More
View Publication Preview PDF
Publication Date
Sat Dec 01 2018
Journal Name
Al-khwarizmi Engineering Journal
Semi-Active Damping of Mechanical Vibrating Systems Using Variable Stiffness Actuator
...Show More Authors

      In this research, a variable stiffness actuator is proposed to enhance the damping of the mechanical vibrating system. The frequency response analysis of the vibrating system is dependant in order to analyze and synthesis this semi-active damping, where the suggested process is using active filter to estimate the present frequency of the vibration system, and this will limit the value of the stiffness of the vibrated system. Two active filter s are needed, low-pass-filter (LPF) to choose the higher stiffness of the actuator at small frequencies as well as more damping and high-pass-filter (HPF) to choose the lower stiffness of the actuator at high frequencies as well as more damping, and so

... Show More