Background : The number of primary hip arthroplasty is growing with every passing year. At present this surgical operation has no equal in the rate of yielding good results. Despite the fact that in many cases in the long term after surgery radiolucent lines around the cup are observed, the clinical outcomes remain satisfactory.
Aim of the study :To study the clinical and radiological manifestations of the aseptic loosening of the endoprosthesis
Methods: This is a prospective study based on an analysis of diagnostic findings of 51 patients with aseptic loosening of hip joint components, aged 30 to 84 years. We depend for diagnosis of a septic losing by both clinical evaluation and X-ray assessment Results:The majority of clinical and radiological evidence of aseptic loosening appear after three years (47%).All our patients had a pain syndrome of varying intensity, with (43.2%) used a walking-stick. Shortening limb from 1 to 7 cm was found in 43 patients 85.2%.
The aseptic losing are common in cementless hip prosthesis especially in femoral stem part of prosthesus 53.9% versus 25.6% in cemented type,
Revision surgery for primary hip prosthesis occur mainly for femoral stem involve 49% while other 25.5% involve both acetabular cup and femoral stem, while the rest of patient(25.5%) involve revision of acetabular cup only. Discussion :At present this surgical operation has no equal in the rate of yielding good results. The lifetime of the majority of artificial joints does not exceed 15 years mainly due to aseptic loosening of one or both endoprosthetic components There are many causes of aseptic instability: substandard surgical technique, unwarranted extension of the indications for arthroplasty, inappropriate choice of the prosthesis dimension type, incorrect installation of components, reaction to the massive foreign body and the development of synovial-like membrane on the metal-bone interface .
As a rule, early instability within 1 year was associated with defects in the operative techniques, from 1 to 3 years mostly due to the wrong selection of the type of primary endoprosthesis while more than 3 years period, the instability was caused by two reasons: excessive load on the operated extremity or traumas and the rapid wear of plastic with large areas of osteolysis due to the high loads or inaccurate positioning of the prosthetic cup.
Conclusions: X-ray examination is the fundamental for diagnosing of aseptic loosening of hip endoprosthesis , and improved surgical techniques, the proper selection of the type of prosthesis are the keys for reduction of risk of aseptic loosening
Abstract
This study aims to identify the repercussions of the Corona pandemic (Covid 19) and its impact on the educational and psychological functions of the Omani family from the point of view of a number of fathers and mothers. Drive for a group of fathers and mothers, some of whom work in the government sector and others are mothers enrolled in graduate studies programs at the university, their ages range between (30-50 years) totally (28) mothers and fathers: 22 mothers and 6 fathers. The results showed that the repercussions of the transformation of e-learning, home quarantine, social distancing, and the challenges associated with them were among the most frequent responses that posed a real challenge to the
... Show MoreThe preparation, spectroscopic characterisation of complexes derived from the mixed ligands with CdII, ZnII and CoII metal ions with Schiff base, Dithiocarbamates (DTCs) and 8-Hydroxyquinoline are reported. The compounds that prepared have been defined via; chloride content, F.T-IR, UV-Vis 1H-NMR spectroscopy and C.H.N.S, as well as conductance and magnetic susceptibility.All data which collected from such methods specified complexes with 6 coordinates in solution and solid states. The biologicalactivity that is related to all the prepared compounds which were screened for their antimicrobial activitiesagainst (G+ and (G- )). The data that collected from biological activity indicate that complexes will have extra activity against such teste
... Show MoreHistorical scripts and Academic studies have bestrewed almost all the events of the movement of march 1941 . Yet the need was present to shine more light on important sides . These important sides were neglected due to some reasons among which came the absence of the historical material which can make a new historical detection. Then there were historical topics concerning our research which comes within context of sanitarily conditions , rarely seizes the attention of the researchers for many reasons some of them were not subjective.
The spread of Malaria among the British force was one of the sanitarily conditions that were related to the movement of march since their arrival to Basra city and its continuous spread after the second
In this paper, three tool paths strategies; iso-planar, helical and adaptive have been implemented to investigates their effect on the mechanical properties of Brass 65-35 formed by single point incremental sheet metal forming process. To response this task, a fully digital integrated system from CAD modeling to finished part (CAD/CAM) for SPIF process has been developed in this paper.
The photo-micrographs shows an identical grain formation due to the plastic deformation of the incremental forming process, change in the grain shape and size was observed. It's found that the adaptive tool path play a significant role to increase the hardness of the formed specimen from (48 to 90 HV) and the grain texture of the formed specimen found a
In This research a Spectroscopic complement and Thermodynamic properties for molecule PO2 were studied . That included a calculation of potential energy . From the curve of total energy for molecule at equilibrium distance , for bond (P-O), the degenerated of bond energy was (4.332eV) instate of the vibration modes of ( PO2 ) molecule and frequency that was found active in IR spectra because variable inpolarization and dipole moment for molecule. Also we calculate some thermodynamic parameters of ( PO2 ) such as heat of formation , enthalpy , heat Of capacity , entropy and gibb's free energy Were ( -54.16 kcal/mol , 2366.45 kcal/mol , 10.06 kcal /k/mol , 59.52 k
... Show MoreThe aim of the current study is to identify the effectiveness of cognitive conflict strategy in comprehending reading among literary fifth students in literature and literature texts. The researcher uses experimental method with partial control. The sample consisted of (80) students distributed into control and experimental groups. The scientific material, the behavioral goals, the teaching plans, and the instrument of the research have been prepared (reading comprehension test) by the researcher.
The instrument's validity and reliability have been calculated and then applied to the sample. After treating the data statistically by using SPSS, the results have revealed that there is a statistically significant difference at the si
... Show MoreVocational education is the basis of contemporary educational movement that aims at satisfying human needs. Societies can develop their human resources via setting programs for the working class as an aspect of the comprehensive national development. Vocational education is the main source of technical cadres the Iraqi labor market requires of the vocational preparatory schools to provide after three years of schooling.
The vocational schools of the governorate of Basra have a number of problems that lead to the lack of proficiency of their graduates. This study is an attempt to identify these problems or obstacles
... Show MoreBackground: Acrylic resin polymer s used in prosthodontic treatment as a denture base material for several decades. Separation and debonding of artificial teeth from denture bases present a laboratory and clinical problem affect patient and dentist. The aim of this study is to evaluate the effect of oxygen plasma and argon plasma treatment of acrylic teeth and thermocycling on bonding strength to hot cured acrylic resin denture base material. Materials and Methods: Sixty denture teeth (right maxillary central incisor) are selected. The denture teeth are waxed onto the beveled surface of rectangular wax block according to Japanese standard for artificial teeth. The control group consisted of 20 denture teeth specimen without any treatment.
... Show More