Evaluation Aseptic Loosening of Primary Hip Arthroplasty
...Show More Authors

Background : The number of primary hip arthroplasty is growing with every passing year. At present this surgical operation has no equal in the rate of yielding good results. Despite the fact that in many cases in the long term after surgery radiolucent lines around the cup are observed, the clinical outcomes remain satisfactory.
Aim of the study :To study the clinical and radiological manifestations of the aseptic loosening of the endoprosthesis
Methods: This is a prospective study based on an analysis of diagnostic findings of 51 patients with aseptic loosening of hip joint components, aged 30 to 84 years. We depend for diagnosis of a septic losing by both clinical evaluation and X-ray assessment Results:The majority of clinical and radiological evidence of aseptic loosening appear after three years (47%).All our patients had a pain syndrome of varying intensity, with (43.2%) used a walking-stick. Shortening limb from 1 to 7 cm was found in 43 patients 85.2%.
The aseptic losing are common in cementless hip prosthesis especially in femoral stem part of prosthesus 53.9% versus 25.6% in cemented type,
Revision surgery for primary hip prosthesis occur mainly for femoral stem involve 49% while other 25.5% involve both acetabular cup and femoral stem, while the rest of patient(25.5%) involve revision of acetabular cup only. Discussion :At present this surgical operation has no equal in the rate of yielding good results. The lifetime of the majority of artificial joints does not exceed 15 years mainly due to aseptic loosening of one or both endoprosthetic components There are many causes of aseptic instability: substandard surgical technique, unwarranted extension of the indications for arthroplasty, inappropriate choice of the prosthesis dimension type, incorrect installation of components, reaction to the massive foreign body and the development of synovial-like membrane on the metal-bone interface .
As a rule, early instability within 1 year was associated with defects in the operative techniques, from 1 to 3 years mostly due to the wrong selection of the type of primary endoprosthesis while more than 3 years period, the instability was caused by two reasons: excessive load on the operated extremity or traumas and the rapid wear of plastic with large areas of osteolysis due to the high loads or inaccurate positioning of the prosthetic cup.
Conclusions: X-ray examination is the fundamental for diagnosing of aseptic loosening of hip endoprosthesis , and improved surgical techniques, the proper selection of the type of prosthesis are the keys for reduction of risk of aseptic loosening

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Jun 19 2021
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Formulation and In-Vitro Evaluation of Meloxicam Solid Dispersion using Natural Polymers.
...Show More Authors

Meloxicam (MLX) is non-steroidal anti -inflammatory, poorly water soluble, highly permeable drug and the rate of its oral absorption is often controlled by the dissolution rate in the gastrointestinal tract. Solid dispersion (SD) is an effective technique for enhancing the solubility and dissolution rate of such drug.

    The present study aims to enhance the solubility and the dissolution rate of MLX by SD technique by solvent evaporation method using sodium alginate (SA), hyaluronic acid (HA), collagen and xyloglucan (XG) as gastro-protective hydrophilic natural polymers.

Twelve formulas were prepared in different drug: polymer ratios and evaluated for their, percentage yield, drug content,  water so

... Show More
View Publication Preview PDF
Scopus (12)
Crossref (5)
Scopus Crossref
Publication Date
Sat Dec 11 2021
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Formulation and in-vitro Evaluation of Carvedilol Gastroretentive Capsule as (Superporous Hydrogel)
...Show More Authors

  The preferred route of drug administration is the oral route, but drugs with narrow absorption window in the gastrointestinal tract are still challenging. The ability to extend and monitor the gastric emptying time is a valuable tool for processes remaining in the stomach longer than other traditional dosage forms.

The purpose of this study was to formulate and evaluate gastroretentive superporous hydrogel (SPH) of carvedilol with view to improve its solubility and increase gastric residence time in order to get sustained release formulas via utilization of various kinds and concentrations of hydrophilic polymers then after, incorporate the best prepared formula into capsules.

 Sixteenth formulae of SPH h

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (3)
Scopus Crossref
Publication Date
Sun Nov 01 2015
Journal Name
Research In Social And Administrative Pharmacy
Evaluation of instruments to assess health literacy in Arabic language among Iraqis
...Show More Authors

View Publication
Scopus (54)
Crossref (45)
Scopus Clarivate Crossref
Publication Date
Wed Aug 13 2025
Journal Name
Mechanics Of Time-dependent Materials
Performance evaluation of highly modified asphalt binders using elastomeric and plastomeric polymers
...Show More Authors

Highly Modified Asphalt (HiMA) binders have garnered significant attention due to their superior resistance to rutting, fatigue cracking, and thermal distress under heavy traffic loads and extreme environmental conditions. While elastomeric polymers such as Styrene- Butadiene-Styrene (SBS) have been extensively used in HiMA applications, the potential of plastomeric polymers, including Polyethylene (PE) and Ethylene Vinyl Acetate (EVA), remains largely unexplored. This study aims to evaluate the performance of reference binder (RB) modified with plastomeric HiMA asphalt in comparison to SBS-modified binders and determine the optimal polymer dosage for achieving an optimal balance between rutting resistance and fatigue durability. The experi

... Show More
View Publication
Scopus Clarivate Crossref
Publication Date
Wed Apr 02 2014
Journal Name
Iraqi Journal Of Physics
The evaluation of left ventricle stiffness index in patients suffering from hypertension
...Show More Authors

Many diseases can produce cardiac overload, of these disease hypertension, valve disease congenital anomaly in addition to many other disease. One of the most common diseases causing left ventricle overload is hypertension. A long term hypertension can cause myocardium hypertrophy leading to changes in the cardiac contractility and reduced efficiency. The investigations were carried out using conventional echocardiography techniques in addition to the tissue Doppler imaging (TDI) from which many noninvasive measurements can be readily obtained. The study has involved the effect of hypertension on the myocardium stiffness index through the measurement of early diastolic filling (E) and the early velocity of lateral mitral annulus (E

... Show More
Publication Date
Thu Dec 15 2022
Journal Name
Al-academy
Evaluation of user interface designs in official websites "Fine Art Colleges Model"
...Show More Authors

I found that it does not meet some of the requirements, including browsing and organizing structural elements, which is something in which the researcher found a scope for research, and from here she can formulate the problem of her research with the following question: Is there an actual need to develop user interface designs in the websites of Iraqi colleges of fine arts? The research included four chapters (the first chapter - the research problem - the second chapter (theoretical framework), which included three sections, the first is to identify the user interface, the second topic is the structural elements, and the third topic includes the rules of interface design and the dimensions of interaction), as well as the third chapter i

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Apr 28 2019
Journal Name
Civil Engineering Journal
Evaluation the Moisture Susceptibility of Asphalt Mixtures Containing Demolished Concrete Waste Materials
...Show More Authors

The distress of moisture induced damage in flexible pavement received tremendous attention over the past decades. The harmful effects of this distress expand the deterioration of other known distresses such as rutting and fatigue cracking. This paper focused on the efficiency of using the waste material of demolished concrete to prepare asphalt mixtures that can withstand the effect of moisture in the pavement. For this purpose, different percentages of waste demolished concrete (0, 10, 20, 30, 50, 70 and 100) were embedded as a replacement for coarse aggregate to construct the base course. The optimum asphalt contents were determined depending on the Marshall method. Then after, two parameters were founded to evaluate the moisture

... Show More
Scopus (12)
Crossref (8)
Scopus Clarivate Crossref
Publication Date
Mon Jan 09 2023
Journal Name
Indian Journal Of Economics And Business
Evaluation of reverse logistics options for international and local companies in Iraq
...Show More Authors

Many international companies have branches or agencies in Iraq and have large market shares, and this has contributed to the increase in the import of these companies' products. This process created an additional problem of handling a large number of expired or defective products. There are many methods that contribute significantly to reducing these problems. The most prominent of these is the activation of reverse logistics options in Iraq by international and local companies. This research aims to conduct a survey of the reverse logistics options approved by some local and international companies and compare between them. This paper found that Amaron, Hitachi, Apple, Samsung and Huawei have limited options for reverse logistics and that

... Show More
Publication Date
Mon Dec 06 2021
Journal Name
Karbala International Journal Of Modern Science
Efficiency of +IDonBlender Photogrammetric Tool in Facial Prosthetics Rehabilitation – An Evaluation Study
...Show More Authors

Scopus (3)
Crossref (2)
Scopus Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Journal Of International Dental And Medical Research
Evaluation of selection criteria for patients indicated for fixed orthodontic appliance treatment
...Show More Authors

Scopus (2)
Scopus