Evaluation Aseptic Loosening of Primary Hip Arthroplasty
...Show More Authors

Background : The number of primary hip arthroplasty is growing with every passing year. At present this surgical operation has no equal in the rate of yielding good results. Despite the fact that in many cases in the long term after surgery radiolucent lines around the cup are observed, the clinical outcomes remain satisfactory.
Aim of the study :To study the clinical and radiological manifestations of the aseptic loosening of the endoprosthesis
Methods: This is a prospective study based on an analysis of diagnostic findings of 51 patients with aseptic loosening of hip joint components, aged 30 to 84 years. We depend for diagnosis of a septic losing by both clinical evaluation and X-ray assessment Results:The majority of clinical and radiological evidence of aseptic loosening appear after three years (47%).All our patients had a pain syndrome of varying intensity, with (43.2%) used a walking-stick. Shortening limb from 1 to 7 cm was found in 43 patients 85.2%.
The aseptic losing are common in cementless hip prosthesis especially in femoral stem part of prosthesus 53.9% versus 25.6% in cemented type,
Revision surgery for primary hip prosthesis occur mainly for femoral stem involve 49% while other 25.5% involve both acetabular cup and femoral stem, while the rest of patient(25.5%) involve revision of acetabular cup only. Discussion :At present this surgical operation has no equal in the rate of yielding good results. The lifetime of the majority of artificial joints does not exceed 15 years mainly due to aseptic loosening of one or both endoprosthetic components There are many causes of aseptic instability: substandard surgical technique, unwarranted extension of the indications for arthroplasty, inappropriate choice of the prosthesis dimension type, incorrect installation of components, reaction to the massive foreign body and the development of synovial-like membrane on the metal-bone interface .
As a rule, early instability within 1 year was associated with defects in the operative techniques, from 1 to 3 years mostly due to the wrong selection of the type of primary endoprosthesis while more than 3 years period, the instability was caused by two reasons: excessive load on the operated extremity or traumas and the rapid wear of plastic with large areas of osteolysis due to the high loads or inaccurate positioning of the prosthetic cup.
Conclusions: X-ray examination is the fundamental for diagnosing of aseptic loosening of hip endoprosthesis , and improved surgical techniques, the proper selection of the type of prosthesis are the keys for reduction of risk of aseptic loosening

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Jun 11 2021
Journal Name
Journal Of Baghdad College Of Dentistry
Management of trauma to the anterior segment of the maxilla: alveolar fracture and primary incisors crown and root fracture
...Show More Authors

Background: An injury to both the primary and permanent teeth and the supporting structures is one of the most common dental problems seen in children. Splinting is usually difficult or impossible to perform in the primary dentition (due to diminutive room size and lack of patient cooperation). Healing must, therefore, occur despite mobility at the fracture line, usually resulting in interposition of connective tissue. In some instances, infection will occur in the coronal pulp. The present study reported a case of trauma to the anterior primary teeth and alveolar bone in a four year old child. The trauma has caused fracture to the crowns and roots of the primary anterior teeth. The following case was managed in a procedure that may

... Show More
View Publication
Scopus (1)
Scopus Crossref
Publication Date
Sun Dec 02 2018
Journal Name
Journal Of The College Of Education For Women
Poverty and its Relations to Some Social Variables (Children in the Primary Stage as a Model)
...Show More Authors

The phenomenon of poverty is one of the most important phenomena facing the world at large. Despite the tremendous technological progress witnessed by mankind and despite the unprecedented high levels of world economic production, poverty remains the greatest challenge facing the world. Statistics and studies have shown that poverty is caused by several problems: (health, social, economic, educational, etc.) These problems are obstacles to the ability to obtain employment opportunities, which leads in the beginning to the growth phenomenon of unemployment, and ultimately to the growth of poverty.

The results of a range of research in the field of psychology have confirmed that children from poor homes suffer from a high level of

... Show More
View Publication Preview PDF
Publication Date
Sat Dec 15 2018
Journal Name
Journal Of Baghdad College Of Dentistry
The Impact of Breastfeeding Duration on the Development of Normal Occlusal Features of the Primary Dentition among Baghdad Preschool Children
...Show More Authors

Background: Normal occlusal features of primary dentition are crucial for normal development of the permanent dentition. Breastfeeding is an important factor for both general and dental health of children. Aim: The aim of the present study is to assess the impact of the breastfeeding duration on the prevalence of normal occlusal features of the primary dentition among preschool children in Baghdad. Materials and Methods: The sample was 630 Iraqi children (270- boys, 360 girls), aged 3-5 years selected from four kindergartens in Baghdad city. The study was carried out through questionnaire and clinical examination. Normal occlusal features were examined as the presence or absence of interincisive spaces (IS) and primate spaces (PS), termi

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Tue Aug 15 2023
Journal Name
Sumer 1
The effect of silver diamine fluoride on the microleakage of glass ionomer restoration in primary teeth at different time intervals
...Show More Authors

Silver diamine fluoride (SDF) has shown effectiveness in hardening tooth structure and killing bacteria. Therefore, it can be used to prevent and arrest dental caries. Riva Star (SDF) treatment alone will stop cavities but will not reverse the cavitation. The Silver Modified Atraumatic Procedure, often known as Smart, is the optimum technique for regaining the tooth's structure and function. Glass ionomer was introduced in (1972) as a new material that has become one of the most widely used materials in restorative dentistry. By releasing fluoride ions, this material has a therapeutic impact on the surrounding tooth structure. Microleakage is the ingress of bacteria, its byproducts, toxins, chemicals, oral fluids, and ions between t

... Show More
View Publication
Scopus (2)
Crossref (2)
Scopus Crossref
Publication Date
Wed Mar 15 2023
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of a novel coating material on the microleakage of glass hybrid restoration in primary teeth – An in vitro study
...Show More Authors

Background: Glass ionomer restorations are widely employed in the field of pediatric dentistry. There is a constant demand for a durable restoration that remains functional until exfoliation. This study aimed to measure and compare the effect of a novel coating material (EQUIA Forte Coat) on the microleakage of glass hybrid restoration (EQUIA Forte HT) in primary teeth. Material and method: Thirty cavitated (class-II) primary molars were allocated randomly into two groups based on the coat application; uncoated (control) and coated group (experimental). Cavities were prepared by the use of a ceramic bur (CeraBur) and restored with EQUIA Forte HT with or without applying a protective coat (EQUIA Forte Coat). Samples went through the

... Show More
Crossref (1)
Crossref
Publication Date
Wed Mar 15 2023
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of a novel coating material on the microleakage of glass hybrid restoration in primary teeth – An in vitro study
...Show More Authors

Background: Glass ionomer restorations are widely employed in the field of pediatric dentistry. There is a constant demand for a durable restoration that remains functional until exfoliation. This study aimed to measure and compare the effect of a novel coating material (EQUIA Forte Coat) on the microleakage of glass hybrid restoration (EQUIA Forte HT) in primary teeth. Material and method: Thirty cavitated (class-II) primary molars were allocated randomly into two groups based on the coat application; uncoated (control) and coated group (experimental). Cavities were prepared by the use of a ceramic bur (CeraBur) and restored with EQUIA Forte HT with or without applying a protective coat (EQUIA Forte Coat). Samples went through the therm

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Tue Sep 28 2021
Journal Name
Journal Of The College Of Education For Women
Awareness of Responsible Citizenship Components among Primary Schoolgirls in Jeddah: أ.د. إيمان سالم أحمد بارعيده , شروق أحمد فيصل المالكي
...Show More Authors

The research examines the awareness of the components of responsible citizenship among primary schoolgirls in Jeddah using a descriptive approach. A test was then prepared, which consists of loyalty, affiliation to homeland, conscious citizenship based on the knowledge of rights, the fulfillment of duties, family roles in education and society revival, homeland and preservation of the components and gains, participation in achievements, and of national heritage. To maintain the validity and reliability of the study, 28-item test of multiple-choice and short essays type was applied to a random sample of (303) female students in the (fourth-fifth-sixth) primary school class in Jeddah. Results have shown that the level of awareness of schoo

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Sep 15 2024
Journal Name
Journal Of Baghdad College Of Dentistry
The reliability of insertion torque as an indicator for primary stability in immediate dental implant: A prospective clinical study
...Show More Authors

Background: The primary stability of the dental implant is a crucial factor determining the ability to initiate temporary implant-supported prosthesis and for subsequent successful osseointegration, especially in the maxillary non-molar sites. This study assessed the reliability of the insertion torque of dental implants by relating it to the implant stability quotient values measured by the Osstell device. Material and methods: This study included healthy, non-smoker patients with no history of diabetes or other metabolic, or debilitating diseases that may affect bone healing, having non-restorable fractured teeth and retained roots in the maxillary non-molar sites. Primary dental implant stability was evaluated using a torque ratc

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Wed Jan 02 2019
Journal Name
Journal Of Educational And Psychological Researches
The Effectiveness of an Educational Unit According To the Constructive Strategy in Developing Thinking Skills for Fifth Primary Students
...Show More Authors

    The current phase distinguish by the rapid scientific development, which pushes individuals to have the necessities of scientific and practical life through the proper scientific thinking which contribute to the development of invention and creativity away from memorizing and indoctrination and encouraging individuals to looking for information and then attempting to process and develop these information instead of being a passive receiver. The investment of minds becomes the logical investment in all societies by preparing the citizen to become able to face life changes and its necessities. It is very important to take care of individuals and develop their mental abilities and thinking skills. The constructive strateg

... Show More
View Publication Preview PDF
Publication Date
Sun Mar 06 2016
Journal Name
Baghdad Science Journal
Addition of Some Primary and Secondary Amines to Graphene Oxide, and Studying Their Effect on Increasing its Electrical Properties
...Show More Authors

Previously many properties of graphene oxide in the field of medicine, biological environment and in the field of energy have been studied. This diversity in properties is due to the possibility of modification on the composition of this Nano compound, where the Graphene oxide is capable of more modification via addition other functional groups on its surface or at the edges of the sheet. The reason for this modification possibility is that the Sp3 hybridization (tetrahedral structure) of the carbon atoms in graphene oxide, and it contains many oxygenic functional groups that are able to reac with other groups. In this research the effect of addition of some amine compounds on electrical properties of graphene oxide has been studied by the

... Show More
View Publication Preview PDF
Crossref (28)
Crossref