Background : The number of primary hip arthroplasty is growing with every passing year. At present this surgical operation has no equal in the rate of yielding good results. Despite the fact that in many cases in the long term after surgery radiolucent lines around the cup are observed, the clinical outcomes remain satisfactory.
Aim of the study :To study the clinical and radiological manifestations of the aseptic loosening of the endoprosthesis
Methods: This is a prospective study based on an analysis of diagnostic findings of 51 patients with aseptic loosening of hip joint components, aged 30 to 84 years. We depend for diagnosis of a septic losing by both clinical evaluation and X-ray assessment Results:The majority of clinical and radiological evidence of aseptic loosening appear after three years (47%).All our patients had a pain syndrome of varying intensity, with (43.2%) used a walking-stick. Shortening limb from 1 to 7 cm was found in 43 patients 85.2%.
The aseptic losing are common in cementless hip prosthesis especially in femoral stem part of prosthesus 53.9% versus 25.6% in cemented type,
Revision surgery for primary hip prosthesis occur mainly for femoral stem involve 49% while other 25.5% involve both acetabular cup and femoral stem, while the rest of patient(25.5%) involve revision of acetabular cup only. Discussion :At present this surgical operation has no equal in the rate of yielding good results. The lifetime of the majority of artificial joints does not exceed 15 years mainly due to aseptic loosening of one or both endoprosthetic components There are many causes of aseptic instability: substandard surgical technique, unwarranted extension of the indications for arthroplasty, inappropriate choice of the prosthesis dimension type, incorrect installation of components, reaction to the massive foreign body and the development of synovial-like membrane on the metal-bone interface .
As a rule, early instability within 1 year was associated with defects in the operative techniques, from 1 to 3 years mostly due to the wrong selection of the type of primary endoprosthesis while more than 3 years period, the instability was caused by two reasons: excessive load on the operated extremity or traumas and the rapid wear of plastic with large areas of osteolysis due to the high loads or inaccurate positioning of the prosthetic cup.
Conclusions: X-ray examination is the fundamental for diagnosing of aseptic loosening of hip endoprosthesis , and improved surgical techniques, the proper selection of the type of prosthesis are the keys for reduction of risk of aseptic loosening
The research aims to identify the concept of financing structure and what are the determinants that affect it and the goals achieved by financing in commercial banks in addition to the sources upon which the financing structure depends consisting of internal financing sources and external financing sources and their connection to the profits of commercial banks. Baghdad, Khaleeji Commercial Bank) registered in the Iraq Stock Exchange during the period for the years (2011-2020) published in the Iraq Stock Exchange from and the research relied on financial analysis tools to analyze the independent variable the following financing structure (the ratio of equity to total assets, the ratio of deposits to Total liabilities, the ratio of loans
... Show MoreThe research aims to identify the positives formulation entrances authors depending on the setting retaining the names of the authors of Arab veterans and cons of setting the entrances to Arab authors ancient depending on the nickname by desktop diligence without reference to a setting retaining the potential to benefit other libraries disciple of retaining existing in sober university libraries. Use the survey method and adopted a questionnaire distributed to the research sample consisting of employees working in the libraries in question and the total number of forms that have been distributed (50) form .tousel search phrase conclusions from them .
1-The lack of authority control depends on it to find a
... Show MoreThe objective of the study was to identify the effectiveness of a training program based on the employment of the educational portal in the development of the skills of the administrative body in the basic education schools in Dhofar Governorate. To achieve the goal, a training program was designed that includes the skills of the educational portal to be met by the administrative body and measuring its effectiveness. A questionnaire to identify training needs, and a notecard to evaluate performance. The study sample consisted of (70) individuals of the administrative staff. The researchers used the descriptive-analytical method to identify the training needs, design and build the training program and the experimental method for applying
... Show MoreAnaemia is a common extra-articular manifestation of rheumatoid arthritis (RA) where anaemia of chronic disease (ACD) and iron deficiency anaemia (IDA) are the two most frequent types. The distinction between these two types of anaemia has always been challenging requiring sophisticated techniques. Serum transferrin receptor (sTfR) a truncated soluble form of the transferrin receptor is one of the parameters that is influenced by the Iron content and supply to the erythrons and is not affected by inflammatory status and therefore the use of the sTfR/log ferritin (sTfR-F) index can be a reliable indicator of functional iron deficiency.
In light of the increasing importance of interim financial statements they provided these lists of information that enables users of accounting information to make wise investment decisions and predict the company's activities in light of changes the updated rather than wait until the end of the year and accessing information provided by the annual financial statements. In light of this research has come to the most important set of conclusions the adoption of interim financial information has been audited by the external auditor to the availability of basic qualitative characteristics in the accounting information contained in the (appropriate and timely manner, reliability and comparability) and this in turn leads to the impact on reli
... Show MorePurpose: This study aimed to compare the stability and marginal bone loss of implants inserted with flapped and flapless approaches 8 weeks after surgery and 3 months after loading. Material and Methods: Thirty SLActive implants were inserted in 11 patients and early loaded with final restoration 8 weeks after healing period. The stability values determined by Osstell and the marginal bone loss measured by CBCT at the initial time (1st) and 8 weeks of the healing period (2nd) and 3 months after loading (3rd). Results: The overall survival rate was 100%. A significant increase in the 3rd implant stability value in the age of ˂ 40. A significant decrease in the 2nd implant stability value in both gender and traumatic zone with a flapless app
... Show More