Background : The number of primary hip arthroplasty is growing with every passing year. At present this surgical operation has no equal in the rate of yielding good results. Despite the fact that in many cases in the long term after surgery radiolucent lines around the cup are observed, the clinical outcomes remain satisfactory.
Aim of the study :To study the clinical and radiological manifestations of the aseptic loosening of the endoprosthesis
Methods: This is a prospective study based on an analysis of diagnostic findings of 51 patients with aseptic loosening of hip joint components, aged 30 to 84 years. We depend for diagnosis of a septic losing by both clinical evaluation and X-ray assessment Results:The majority of clinical and radiological evidence of aseptic loosening appear after three years (47%).All our patients had a pain syndrome of varying intensity, with (43.2%) used a walking-stick. Shortening limb from 1 to 7 cm was found in 43 patients 85.2%.
The aseptic losing are common in cementless hip prosthesis especially in femoral stem part of prosthesus 53.9% versus 25.6% in cemented type,
Revision surgery for primary hip prosthesis occur mainly for femoral stem involve 49% while other 25.5% involve both acetabular cup and femoral stem, while the rest of patient(25.5%) involve revision of acetabular cup only. Discussion :At present this surgical operation has no equal in the rate of yielding good results. The lifetime of the majority of artificial joints does not exceed 15 years mainly due to aseptic loosening of one or both endoprosthetic components There are many causes of aseptic instability: substandard surgical technique, unwarranted extension of the indications for arthroplasty, inappropriate choice of the prosthesis dimension type, incorrect installation of components, reaction to the massive foreign body and the development of synovial-like membrane on the metal-bone interface .
As a rule, early instability within 1 year was associated with defects in the operative techniques, from 1 to 3 years mostly due to the wrong selection of the type of primary endoprosthesis while more than 3 years period, the instability was caused by two reasons: excessive load on the operated extremity or traumas and the rapid wear of plastic with large areas of osteolysis due to the high loads or inaccurate positioning of the prosthetic cup.
Conclusions: X-ray examination is the fundamental for diagnosing of aseptic loosening of hip endoprosthesis , and improved surgical techniques, the proper selection of the type of prosthesis are the keys for reduction of risk of aseptic loosening
The effectiveness of (200 m) of the events of extreme intensity and this is characterized by training in the anaerobic energy system prevailing in the result of this privacy as these are based on the physical abilities and functional indicators identified in this direction and hence the importance of research in the evaluation of training programs on the basis of physical abilities and some indicators of the functionality of the hostile 200 m . The study aimed to: 1. Evaluation of training programs according to physical abilities and some functional indicators of hostile men.The researchers used the descriptive analytical method to suit the nature of the research. The researchers selected them research sample by the deliberate method of the
... Show MoreThe Red Palm Weevil (RPW), Rhynchophorus ferrugineus (Olivier, 1790) is a devastating invasive pest of palm trees, invading the Iraqi date palm tree in 2015 for the first time in Safwan county, Basrah province. The Red Palm weevil has been categorized as a quarantine pest of date palm trees worldwide. In this study, a five years monitoring program has been achieved by scouting the invasive pest RPW population in Safwan county by using visual sampling and Pheromone baited traps.
The results indicated that the number of infested palms, increased from 12 trees in 2015 to 111 in 16 orchards in 2016. The number of the infested palms was minimized to 3 trees in the county in 2019 due to the management protocol of the Ministry of Agriculture
Volatile organic compounds (VOCs) from uninfested and infested broccoli plant samples with green peach aphid
Background. Dental implantation has become a standard procedure with high success rates, relying on achieving osseointegration between the implant surface and surrounding bone tissue. Polyether ether ketone (PEEK) is a promising alternative to traditional dental implant materials like titanium, but its osseointegration capabilities are limited due to its hydrophobic nature and reduced surface roughness. Objective. The aim of the study is to increase the surface roughness and hydrophilicity of PEEK by treating the surface with piranha solution and then coating the surface with epigallocatechin-3-gallate (EGCG) by electrospraying technique. Materials and Methods. The study includes four groups intended to investigate the effect of pir
... Show MoreThis study is carried out on patients with type 2 diabetes mellitus to assess the lipid profile, malondialdehyde and glutathione. Our study is concerned with 51 (Iraqi Arab females) patients of type 2 diabetes mellitus compared with 31 control subjects unified in age, sex and ethnic background. Lipid profile is measured by using commercially available kits, while the serum MDA and glutathione levels are measured by means of sandwich ELISA test using commercially available kits. Serum MDA is significantly higher (P<0.001) while glutathione is significantly lower (P<0.001) in type 2 diabetic patients when compared to the control. The normal levels of MDA (3.82 ± 0.77n mol/ml) and GSH (2.23 ± 0.54 µg/ml) recorded for the non-diabetic female
... Show MoreThis paper was aimed to evaluate the polyurethane (PU) and polyurethane/polyvinyl chloride (90 wt. % / 10 wt. %) as organic coating of carbon steel substrate against marine environment (3.5 wt.% NaCl aqueous solution) as a severe corrosion environment . The electrochemical impedance spectroscopy (EIS) and fitting impedance data by ZsimpWin 3.22 software were used to estimate the physical barrier of the samples for different exposure times. Different equivalent electrical circuits were proposed for the physical barrier at different immersion times to get appropriate fitting .Both PU and PU/PVC coatings showed excellent corrosion protection ability for steel .The PU/PVC coating showed better protection and stability than PU coating against
... Show MoreSolid dispersion (SD) is one of the most widely used methods to resolve issues accompanied by poorly soluble drugs. The present study was carried out to enhance the solubility and dissolution rate of Aceclofenac (ACE), a BCS class II drug with pH-dependent solubility, by the SD method. Effervescent assisted fusion technique (EFSD) using different hydrophilic carriers (mannitol, urea, Soluplus®, poloxamer 188, and poloxamer 407) in the presence of an effervescent base (sodium bicarbonate and citric acid) in different drug: carrier: effervescent base ratio and the conventional fusion technique (FSD) were used to prepare ACE SD. Solubility, dissolution rate, Fourier transformation infrared spectroscopy (FTIR), PowderX-ray diffraction
... Show MoreThe key objective of the study is to understand the best processes that are currently used in managing talent in Australian higher education (AHE) and design a quantitative measurement of talent management processes (TMPs) for the higher education (HE) sector.
The three qualitative multi-method studies that are commonly used in empirical studies, namely, brainstorming, focus group discussions and semi-structured individual interviews were considered. Twenty