Background : The number of primary hip arthroplasty is growing with every passing year. At present this surgical operation has no equal in the rate of yielding good results. Despite the fact that in many cases in the long term after surgery radiolucent lines around the cup are observed, the clinical outcomes remain satisfactory.
Aim of the study :To study the clinical and radiological manifestations of the aseptic loosening of the endoprosthesis
Methods: This is a prospective study based on an analysis of diagnostic findings of 51 patients with aseptic loosening of hip joint components, aged 30 to 84 years. We depend for diagnosis of a septic losing by both clinical evaluation and X-ray assessment Results:The majority of clinical and radiological evidence of aseptic loosening appear after three years (47%).All our patients had a pain syndrome of varying intensity, with (43.2%) used a walking-stick. Shortening limb from 1 to 7 cm was found in 43 patients 85.2%.
The aseptic losing are common in cementless hip prosthesis especially in femoral stem part of prosthesus 53.9% versus 25.6% in cemented type,
Revision surgery for primary hip prosthesis occur mainly for femoral stem involve 49% while other 25.5% involve both acetabular cup and femoral stem, while the rest of patient(25.5%) involve revision of acetabular cup only. Discussion :At present this surgical operation has no equal in the rate of yielding good results. The lifetime of the majority of artificial joints does not exceed 15 years mainly due to aseptic loosening of one or both endoprosthetic components There are many causes of aseptic instability: substandard surgical technique, unwarranted extension of the indications for arthroplasty, inappropriate choice of the prosthesis dimension type, incorrect installation of components, reaction to the massive foreign body and the development of synovial-like membrane on the metal-bone interface .
As a rule, early instability within 1 year was associated with defects in the operative techniques, from 1 to 3 years mostly due to the wrong selection of the type of primary endoprosthesis while more than 3 years period, the instability was caused by two reasons: excessive load on the operated extremity or traumas and the rapid wear of plastic with large areas of osteolysis due to the high loads or inaccurate positioning of the prosthetic cup.
Conclusions: X-ray examination is the fundamental for diagnosing of aseptic loosening of hip endoprosthesis , and improved surgical techniques, the proper selection of the type of prosthesis are the keys for reduction of risk of aseptic loosening
The present study was included the isolation of Keratinophilic fungi from water samples taken from 19 indoor public swimming pools in Baghdad during four season (summer ,fall ,spring ,and winter). Isolation period was September 2011and September 2012 . Samples were collected from different places in swimming pool . Sixteen keratinophilic fungal species, belonging to twenty –one genera were isolated using Surface Dilution Plating (SDP) and Hair Bait Technique (HBT) . Aspergillus genus was the most frequent and occurrence (19.84%), followed by Trichophyton (11.60%) and Fusarium (7.59% ) . The most common fungal infection occurred in summer season (42.16%) , and the most frequent month manifestation of species occurred in August
... Show MorePraise be to God, who said: {And establish prayer and pay zakat and lend to God a good loan, and whatever good you put forward for yourselves you will find with God. It is better and greater in reward. Ask forgiveness of God. Indeed, God is Forgiving, Most Merciful. May blessings and peace be upon Muhammad, the servant of God, and His Messenger, may God bless him and grant him peace, who said: “Islam is built on five Testifying that there is no god but God and that Muhammad is the Messenger of God, establishing prayer, paying zakat, Hajj, and fasting Ramadan” ().
Now that follows: Islamic law aims to make man happy in this world and the afterlife, starting with faith in God Almighty until the end of the legal obligations. This is
The aim of the current study is to identify the morphological description of the tongue in mongoose (Herpestes javanicus) and its relation to the feeding pattern. For this purpose the (5) samples of tongues were dissected from the head of mongoosecaught from different areas of Al-Najaf province, cleaned in normal saline and examined under the dissecting microscope. The results showed the absence of the middle groove in the lingual apex area. As well as the absence of lingual prominence in the body area. The dorsal surface is characterized by the presence of four types from lingual papillae (filiform, cylindrical, fungiform, circumvallate), while the ventral surface is free of lingual papillae. The filiform papillae spread throughout the dor
... Show MoreThe Dielectric properties of EP/TiO2 and MgO nanocomposite at
a frequency range of (102-106 Hz) were studied. The composite were
prepared with the state volume ratio (0, 0.05, 0.1) for EP/TiO2 and
MgO respectively. The impedance, dielectric constant and dielectric
loss were found decrease with frequency increase.
The effect of operating parameters on the batch scale separation of hydrocarbon mixture (benzene and hexane) using
emulsion liquid membrane technique is reported. Sparkleen detergent was used as surfactant and heavy mineral oil as
solvent to receive the permeates.
From the experimental results, the parameters that influenced the permeation are, composition of feed, contact time
with solvent, ratio of volume of solvent to volume of hydrocarbon feed, ratio of volume of surfactant solution to volume
of hydrocarbon feed, surfactant concentration, mixing intensity and glycerol as polar additive in the surfactant solution
to eliminate drop breakup.
The best conditions for the separation in this study were found to be: comp
This research studies the effect of particle packing density on sintering TiO2 microstructure. Sintering experiment was conducted on compacts involving of monodisperse spherical TiO2 particles. The experimental results are modeled using L2-Regression technique in studing the effect of two theoretical values of 55% and 69% of initial packing densities. The mathematical simulation shows that the lower values of density compacts sintered fast to theoretical density and this reflects that particle packing density improved densification rate because of the competing influence of grain growth at higher values of densities.
