Preferred Language
Articles
/
jkmc-187
Evaluation Aseptic Loosening of Primary Hip Arthroplasty
...Show More Authors

Background : The number of primary hip arthroplasty is growing with every passing year. At present this surgical operation has no equal in the rate of yielding good results. Despite the fact that in many cases in the long term after surgery radiolucent lines around the cup are observed, the clinical outcomes remain satisfactory.
Aim of the study :To study the clinical and radiological manifestations of the aseptic loosening of the endoprosthesis
Methods: This is a prospective study based on an analysis of diagnostic findings of 51 patients with aseptic loosening of hip joint components, aged 30 to 84 years. We depend for diagnosis of a septic losing by both clinical evaluation and X-ray assessment Results:The majority of clinical and radiological evidence of aseptic loosening appear after three years (47%).All our patients had a pain syndrome of varying intensity, with (43.2%) used a walking-stick. Shortening limb from 1 to 7 cm was found in 43 patients 85.2%.
The aseptic losing are common in cementless hip prosthesis especially in femoral stem part of prosthesus 53.9% versus 25.6% in cemented type,
Revision surgery for primary hip prosthesis occur mainly for femoral stem involve 49% while other 25.5% involve both acetabular cup and femoral stem, while the rest of patient(25.5%) involve revision of acetabular cup only. Discussion :At present this surgical operation has no equal in the rate of yielding good results. The lifetime of the majority of artificial joints does not exceed 15 years mainly due to aseptic loosening of one or both endoprosthetic components There are many causes of aseptic instability: substandard surgical technique, unwarranted extension of the indications for arthroplasty, inappropriate choice of the prosthesis dimension type, incorrect installation of components, reaction to the massive foreign body and the development of synovial-like membrane on the metal-bone interface .
As a rule, early instability within 1 year was associated with defects in the operative techniques, from 1 to 3 years mostly due to the wrong selection of the type of primary endoprosthesis while more than 3 years period, the instability was caused by two reasons: excessive load on the operated extremity or traumas and the rapid wear of plastic with large areas of osteolysis due to the high loads or inaccurate positioning of the prosthetic cup.
Conclusions: X-ray examination is the fundamental for diagnosing of aseptic loosening of hip endoprosthesis , and improved surgical techniques, the proper selection of the type of prosthesis are the keys for reduction of risk of aseptic loosening

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Jul 30 2020
Journal Name
Journal Of Sustainability Science And Management
THE DIFFERENTIATION IN WORK ENRICHMENT STRATEGIES AND ORGANIZATIONAL CREATIVITY FUNCTION: A PERSPECTIVE FROM THE LEADERS OF THE MINISTRY OF OIL IN IRAQ
...Show More Authors

View Publication
Scopus (5)
Crossref (2)
Scopus Crossref
Publication Date
Sun Mar 15 2020
Journal Name
Journal Of The College Of Education For Women
The Degree of Using Computers in Administrative Jobs and the Obstacles of Usage in Public Education Schools in Sharoorah Governorate: Saudi Arabia
...Show More Authors

This study aimed to identify the degree of use computers in administrative functions (planning, organization, controlling, and evaluation) among school leaders and assistants in public education schools in Sharoorah governorate ، as well as to identify obstacles of  use computers in administrative functions from the perspective of school leaders and assistants male and female in public schools during the academic year 1439-1440, the study sample  (66) school leaders and assistants, males (58), a and females (44), , and to answer the questions of the study, the researchers developed a questionnaire consisting of  (60) items, has been verified sincerity and persistence, and data analysis was used frequencies, percentages an

... Show More
View Publication Preview PDF
Publication Date
Tue Dec 01 2015
Journal Name
Journal Of Al-nahrain University-science
Synthesis of Polyacrylamides from Derivatives 2-Aminobenzothiazole and also Preparation of Dibutylphthalate as a Plasticizer to Estimate Plasticization Behaviour for Prepared Polymers
...Show More Authors

View Publication
Crossref
Publication Date
Sat Jan 02 2021
Journal Name
Journal Of Physics: Conference Series
First record of Myxobolus insignis Eiras, Malta, Varella, Pavanelli, 2005 (Myxozoa: Myxobolidae) in Iraq from gills of the common carp Cyprinus carpio
...Show More Authors

First record of Myxobolus insignis Eiras, Malta, Varella, Pavanelli, 2005 (Myxozoa: Myxobolidae) in Iraq from gills of the common carp Cyprinus carpio

Publication Date
Sat Jul 12 2025
Journal Name
Journal Of The College Of Law /al-nahrain University
The financial regulations approved in private universities and colleges in accordance with the Law of Private Higher Education No. (25) of 2016
...Show More Authors

View Publication
Publication Date
Sun Jan 01 2023
Journal Name
Dental Hypotheses
Effect of Dentin Surface Pretreatment With Chitosan Nanoparticles on Immediate and Prolonged Shear Bond Strength of Resin Composite: An in Vitro Study
...Show More Authors

View Publication
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Mon Jan 01 2024
Journal Name
Aip Conference Proceedings
Investigation in vitro the effect of X-rays, gamma rays and beta particles on the physical and structural characteristics of human teeth
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Sun Sep 01 2013
Journal Name
Baghdad Science Journal
Synthesis ,spectroscopic study of Antipyryl azo 2-Naphthol and use it as new reagent for determination of Co(II) and Cu(II)
...Show More Authors

A simple ,accurate and sensitive spectrophotometric method has been developed the determination of Cobalt(II) and Cupper (II) .The method is based on the chelation of Co(II) and Cu(II) ions with 4-(4´-pyrazolon azo) -2-Naphthol(APAN) in aqueous medium . The complexes have a maximum absorption at (513) and (506) nm and ? max 0.531×10 4 and 0.12×10 5 L.mol -1.cm -1 for Co(II) and Cu(II) respectively .The reagent and two complexes have been prepared in ethanolic solution.The stoichiometry of both complexes were found to be 1:2 (metal :legend) .The effects of various cations and anions on Co(II) and Cu(II) determination have been investigated .The stability constants and standard deviations for Co(II) and Cu(II) 0.291 x107 ,0.909X108 L.mol

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Feb 04 2019
Journal Name
Iraqi Journal Of Physics
Effects of Q-switched Nd: YAG laser irradiation on the aqueous solution of human albumin and calf-thymus double strand DNA (ctds)
...Show More Authors

Q-switched lasers widely used in management skin diseases and
sometimes its effect may be inadequate or associated with
cytotoxicity. The current study aimed to investigate the effect of
Q-switched Nd:YAG laser upon cellular elements using in vitro
experimental model. Aqueous solutions of human albumin and pure
calf thymus double strand deoxyribonucleic acid (ctdsDNA)
irradiated with Q-switched Nd:YAG laser at different rates (1, 3 Hz)
and time exposure (up to 60 seconds) using 532 nm (400 mJ) and
1064 (1200 mJ) nm wavelength with fixed spot size of 4 mm. The
effect of laser irradiation on the albumin solution also studied in the
presence of elemental salts of copper, zinc and iron.
Q-switched laser irrad

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jan 01 2017
Journal Name
Journal Of Cosmetics, Dermatological Sciences And Applications
Burn Hemangioma (BH) (Scalded Pyogenic Granuloma) versus Infantile Hemangioma: Report of Six Cases of BH and Its Effective Therapy with Oral Propranolol
...Show More Authors

View Publication
Crossref