Evaluation Aseptic Loosening of Primary Hip Arthroplasty
...Show More Authors

Background : The number of primary hip arthroplasty is growing with every passing year. At present this surgical operation has no equal in the rate of yielding good results. Despite the fact that in many cases in the long term after surgery radiolucent lines around the cup are observed, the clinical outcomes remain satisfactory.
Aim of the study :To study the clinical and radiological manifestations of the aseptic loosening of the endoprosthesis
Methods: This is a prospective study based on an analysis of diagnostic findings of 51 patients with aseptic loosening of hip joint components, aged 30 to 84 years. We depend for diagnosis of a septic losing by both clinical evaluation and X-ray assessment Results:The majority of clinical and radiological evidence of aseptic loosening appear after three years (47%).All our patients had a pain syndrome of varying intensity, with (43.2%) used a walking-stick. Shortening limb from 1 to 7 cm was found in 43 patients 85.2%.
The aseptic losing are common in cementless hip prosthesis especially in femoral stem part of prosthesus 53.9% versus 25.6% in cemented type,
Revision surgery for primary hip prosthesis occur mainly for femoral stem involve 49% while other 25.5% involve both acetabular cup and femoral stem, while the rest of patient(25.5%) involve revision of acetabular cup only. Discussion :At present this surgical operation has no equal in the rate of yielding good results. The lifetime of the majority of artificial joints does not exceed 15 years mainly due to aseptic loosening of one or both endoprosthetic components There are many causes of aseptic instability: substandard surgical technique, unwarranted extension of the indications for arthroplasty, inappropriate choice of the prosthesis dimension type, incorrect installation of components, reaction to the massive foreign body and the development of synovial-like membrane on the metal-bone interface .
As a rule, early instability within 1 year was associated with defects in the operative techniques, from 1 to 3 years mostly due to the wrong selection of the type of primary endoprosthesis while more than 3 years period, the instability was caused by two reasons: excessive load on the operated extremity or traumas and the rapid wear of plastic with large areas of osteolysis due to the high loads or inaccurate positioning of the prosthetic cup.
Conclusions: X-ray examination is the fundamental for diagnosing of aseptic loosening of hip endoprosthesis , and improved surgical techniques, the proper selection of the type of prosthesis are the keys for reduction of risk of aseptic loosening

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Nov 08 2025
Journal Name
Journal Of Sport Sciences
The school system and its relationship to the evolution of some indicators of physical and functional skills in a lesson and basketball
...Show More Authors

View Publication
Publication Date
Sat Sep 28 2024
Journal Name
Journal Of The Pakistan Medical Association
Pulse transmission time and amplitude of digital pulse wave determined by fingertip plethysmography as a surrogate marker of brachial artery flowmediated dilatation
...Show More Authors

Objectives: To assess the changes in blood vessel stiffness and digital pulse wave amplitude because of flowmediateddilatation, and to explore how these two variables change when endothelial dysfunction isexperimentally induced.Method: The experimental study was conducted at the departments of physiology at the College of Medicine,Mustansiriyah University, and the College of Medicine, Al-Iraqia University, Baghdad, Iraq, from October 14, 2021, toMay 31, 2022, and comprised healthy young males who were subjected to the flow-mediated dilatation techniqueon the left brachial artery. Pulse transit time and the amplitude of the digital pulse wave were measured duringreactive hyperaemia for 2.5 minutes from the left middle finger using a

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Sat Nov 08 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of silanized alumina nano -fillers addition on some physical and mechanical properties of heat cured polymethyl methacrylate denture base material
...Show More Authors

Background: Polymethyl methacrylate (PMMA) is the most commonly used material in denture fabrication. The material is far from ideal in fulfilling the mechanical requirements. Midline fracture; poor thermal conductivity and water sorption, are common problem in this material. The purpose of this study was to evaluate the effect of addition of surface treated Aluminum oxide nano fillers on some properties of heat cured (PMMA). Materials and methods: In addition to controlled group of heat cured PMMA the silanized (Al2O3) nanoparticles was added to PMMA powder by weight in three different percentages 1wt%, 2wt% and 3wt%, mixed by probe ultra-sonication machine. 200 specimens were constructed and divided into 5 groups according to the test (e

... Show More
View Publication Preview PDF
Publication Date
Sun Jan 01 2017
Journal Name
Biochemical And Cellular Archives
Response of red cabbage to the adding wheat peatand spraying with its extract and organic nutrient vegeamino on qualitative characteristics of heads
...Show More Authors

Scopus (1)
Scopus
Publication Date
Tue Nov 09 2021
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
Financial technology as one of the recovery strategies of the Iraqi banking sector in the post-Covid-19 stage: An exploratory study
...Show More Authors

The research aims to employ one of the most important strategies for recovery from the crisis of the Covid-19 pandemic, which ravaged the economies of the entire world and its various sectors, including the banking sector, through financial technology that is based on digital transformation to achieve financial sustainability and the creation of innovative financial value chains in light of the decline in the banking sector as a result of The negative effects of the Covid-19 pandemic, be guided by the relevant international accounting standards to control the risks associated with financial technology. To recover from the Covid-19 crisis, the research came out with a set of recommendations, most notably financial technology from

... Show More
View Publication Preview PDF
Publication Date
Fri Mar 01 2013
Journal Name
Journal Of Economics And Administrative Sciences
Employment of exploratory factor analysis to extract factors Organizational Loyalty and job satisfaction Case Study in the College of Technology Management – Baghdad
...Show More Authors

According to the measuring the relationship between organizational loyalty and job satisfaction among staff members at one college in the higher education ministry in Iraq by using exploratory factor analysis methods to extraction the components which have the major effects on the variables related to organizational loyalty and job satisfaction .

The research contains four basic topics، the first section related to methodology and regarding the conceptual framework it is discussed in the second section، and the third section concentrated at the presentation and the analysis Scientific results and practical results are section presented in the fourth.

 

View Publication Preview PDF
Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
The effect of the dimensions of the strategic lens on achieving tax pioneer performance: Practical research in the General Authority for Taxes
...Show More Authors

The aim of the research is to shed light on the dimensions of the strategic lens and its impact on achieving the pioneer tax performance and represented by the dimensions (strategic direction, growth, pilot indicator, renewal and modernization, efficiency and effectiveness) in the General Tax Authority. The questionnaire was adopted as a tool to collect data and information from the adult sample They are (91) who are on the site (Assistant Director General, Head of Division, First Division Deputy, Second Division Deputy, Division Officer, Division Officer Associate) The statistical program (SPSS) has been used to calculate (the mean, the standard deviation, the correlation coefficient, the difference coefficient, the F test, the

... Show More
View Publication Preview PDF
Publication Date
Sun Jun 05 2016
Journal Name
Baghdad Science Journal
Effect of some induce chemical and biological agents against (Tilletia tritici (Bjerk) and T.laevis (Kühn) causal agents of wheat Common bunt disease
...Show More Authors

This study was conducted to evaluate the efficiency of some chemicals and biological agents to induce systemic resistance (ISR) against to wheat common bunt disease caused by the two species of fungus Tilletia tritici (Bjerk.) Wint (T. caries (Dac.) Tul.) and T. laevis Kuhn (T. foetida (Wall.) Liro. Trails in the efforts to find an alternative, safe and environmentally friendly means to control the disease. Results of this study which carried out during two consecutive seasons for the years 2012 - 2013 and 2013 - 2014 at two different environmental locations. Seed treatment by (SA 100 and 200 mg/L, 500 ?–aminobutyric acid (BABA) and 1000 mg/L, Effective Microorganisms (EM1) 40 and 150 ml/kg seeds) have led to high significant redu

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sat Nov 08 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of different palatal vault shapes and woven glass fiber reinforcement on dimensional stability of high impact acrylic denture base [Part I]
...Show More Authors

Background: Change in palatal vault shape and Reinforcement of high impact acrylic denture base resin may in turn affect the dimensional accuracy of acrylic resin and affecting the fitness of the denture.This study evaluated tostudy the effect of fiber reinforcement for high-impact acrylic resin denture base with different palatal vault shapes on adaptation or gap space between the denture base and the stone cast and compare with non-fiber reinforcement and effect of palatal vault shapes on adaptation of non-reinforced and fiber reinforced high impact denture base acrylic resin Material and method: Three different palatal vault shapes were prepared on standard casts using CNC (computer numerical control) machine. 60 samples of heat polymeri

... Show More
View Publication Preview PDF
Publication Date
Sun Jan 01 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Scienc
Synthesis, Spectral and Bacterial Studies of Mixed Ligand Complexes of Schiff Base Derived from Methyldopa and Anthranilic Acid with Some Metal Ions
...Show More Authors

Bidentate Schiff base ligand 3-(3,4-Dihydroxy-phenyl)-2-[(4-dimethylamino-benzylidene)-amino]-2-methyl-propionic acid was prepared and characterized by spectroscopic techniques studies and elemental analysis. The Cd(II), Ni(II), Cu(II), Co(II), Cr(III),and Fe(III) of mixed-ligand complexes were structural explicate through Moler conductance , [FT-IR, UV-Vis & AAS], chloride contents, , and magnetic susceptibility measurements. Octahedral geometries have been suggested for all complexes. The Schiff base and its complexes were tested against various bacterial species, two of {gram(G+) and gram(G-)} were shown weak to good activity against all bacteria.

Preview PDF