Background : The number of primary hip arthroplasty is growing with every passing year. At present this surgical operation has no equal in the rate of yielding good results. Despite the fact that in many cases in the long term after surgery radiolucent lines around the cup are observed, the clinical outcomes remain satisfactory.
Aim of the study :To study the clinical and radiological manifestations of the aseptic loosening of the endoprosthesis
Methods: This is a prospective study based on an analysis of diagnostic findings of 51 patients with aseptic loosening of hip joint components, aged 30 to 84 years. We depend for diagnosis of a septic losing by both clinical evaluation and X-ray assessment Results:The majority of clinical and radiological evidence of aseptic loosening appear after three years (47%).All our patients had a pain syndrome of varying intensity, with (43.2%) used a walking-stick. Shortening limb from 1 to 7 cm was found in 43 patients 85.2%.
The aseptic losing are common in cementless hip prosthesis especially in femoral stem part of prosthesus 53.9% versus 25.6% in cemented type,
Revision surgery for primary hip prosthesis occur mainly for femoral stem involve 49% while other 25.5% involve both acetabular cup and femoral stem, while the rest of patient(25.5%) involve revision of acetabular cup only. Discussion :At present this surgical operation has no equal in the rate of yielding good results. The lifetime of the majority of artificial joints does not exceed 15 years mainly due to aseptic loosening of one or both endoprosthetic components There are many causes of aseptic instability: substandard surgical technique, unwarranted extension of the indications for arthroplasty, inappropriate choice of the prosthesis dimension type, incorrect installation of components, reaction to the massive foreign body and the development of synovial-like membrane on the metal-bone interface .
As a rule, early instability within 1 year was associated with defects in the operative techniques, from 1 to 3 years mostly due to the wrong selection of the type of primary endoprosthesis while more than 3 years period, the instability was caused by two reasons: excessive load on the operated extremity or traumas and the rapid wear of plastic with large areas of osteolysis due to the high loads or inaccurate positioning of the prosthetic cup.
Conclusions: X-ray examination is the fundamental for diagnosing of aseptic loosening of hip endoprosthesis , and improved surgical techniques, the proper selection of the type of prosthesis are the keys for reduction of risk of aseptic loosening
The search consists of four chapters, which are as follows: -First Chapter,The research shows the problem and the importance and its need, its aim and limits are to identify the terms of it consist. The problem of the research has been identified by answering the following question:How to representthe significant displacement of the Crucifixion of Jesus Christ in contemporary drawing? ,The aim of the research also has been discussed around what it represents: The significant displacement of the Crucifixion of Jesus Christ in contemporary drawingshows. As for the research limits .the portress which are taken from a variety of sources, and the period of time of the year (1945-2008).fearst chapter;The theoretical framework and previous stud
... Show MoreObjectives: The study aims to assess and evaluate the caregivers knowledge about management of the children with growth hormone deficiency and to find out the relationship between caregivers kowledge and caregivers age, gender, number of individual in house hold, Date of treatment started ,Caregivers level education and economic status Methodology: Quazi expermental study design was carried out at (Child's Central Teaching Hospital, Medical City of Al Imamian Al Khadhmain Teaching Hospital, and National Centre for Treatment and Research of Diabetes,Specialized Center for Endocrine Diseases and Diabetes, and Department of Medical City Children Welfare Teaching Hospital started from
... Show MoreObjectives: To find out the effectiveness of education program application on nurses-midwives' knowledge toward prevention and management of postpartum hemorrhage in delivery room and some socio demographic characteristics Methodology: a quasi -experimental "test-retest"design has carried throughout the present study with the application of a pre –test and post- test for nurses-midwives' knowledge toward postpartum hemorrhage. The study was conducted in six hospitals in Baghdad: Fatima Al – Zahra for Maternity and Pediatric, Al -Elwia maternity, Baghdad Teaching, AL-Imamine Al - Kadhimin Teaching, Al-Karckh maternity and Al-Yarmouk Teaching hospital for the period from 27th May
... Show MoreThe acrylic polymer composites in this study are made up of various weight ratios of cement or silica nanoparticles (1, 3, 5, and 10 wt%) using the casting method. The effects of doping ratio/type on mechanical, dielectric, thermal, and hydrophobic properties were investigated. Acrylic polymer composites containing 5 wt% cement or silica nanoparticles had the lowest abrasion wear rates and the highest shore-D hardness and impact strength. The increase in the inclusion of cement or silica nanoparticles enhanced surface roughness, water contact angle (WCA), and thermal insulation. Acrylic/cement composites demonstrated higher mechanical, electrical, and thermal insulation properties than acrylic/silica composites because of their lowe
... Show MoreThis study was aimed to investigate the response of two types of ornamental herbaceous plants (Wedelia trilobata and Jacobaea maritima 'Cirrus') to different agricultural environments and the application of potassium silicates to the living walls system LWS (Felt layer system) under the climate conditions of Baghdad city. Each experiment involved the cultivation of a different plant species, and the study duration was from September 15, 2021, to August 1, 2022. A Strip-Plot Design experiment was conducted using two factors: factor M with four levels of substrates (50% peatmoss and perlite (M1), 50% Vermicompost and perlite (M2), 50% Water hyacinth compost and perlite (M3), 50% wheat straw compost and perlite (M4)) and factor S with
... Show MoreOrganic soil is problematic soils in geotechnical engineering due to its properties, as it is characterized by high compressibility and low bearing capacity. Therefore, several geotechnical techniques tried to stabilize and improve this soil type. In this study, sodium silicate was used to stabilize sand dune columns. The best sodium silicate concentration (9%) was used, and the stabilized sand dune columns were cured for seven days. The results for this soil were extracted using a numerical analysis program (Plaxis 3D, 2020).In the case of studying the effect of (L/D) (where ‘’L” and ‘’D’’ length and diameter of sand dune columns) of a single column of sand dunes stabilized with sodium silicate with a diff
... Show MoreBackground: Information concerning the maximum bite force in human population is important to clinical orthodontics. Additionally, the influence of bite force on the vertical stability of any treatment result is important. The new position of the dentition should be compatible with the dynamics of the muscular and occlusal forces in all planes. This study was conducted to 1) to measure and compare maximum bite force, body height and weight among normal occlusion and malocclusion groups (cl I,cl II,cl III) in both gender 2) to evaluate the correlation between bite force and craniofacial morphology, body height and weight. Materials and Methods: The sample consists of 100 Iraqi adult subjects aged 18-25 years. It was classified in to four gr
... Show More