Preferred Language
Articles
/
jkmc-159
Role of Multi-Detector CT Angiography in Assesmente of Athrosclerotic Coronary Artery Disease
...Show More Authors

Background:  Imaging has a critical role in the diagnosis and evaluation of cardiac diseases, beginning with chest radiography and fluoro-scopy and progressing to coronary angio-graphy, echocardiography, nuclear medicine and recently  multidetector computed tomo-graphy (MDCT) as well as magnetic resonance (MR) imaging

Objective: To highlight the role of Multi-detector CT in the evaluation of coronary artery disease and its importance of being noninvasive diagnostic technique.

Methods: A cross sectional study for 20 patients. Patients were asked to fast 6 hours prior to the examination and the patients with heart rates above 65 beats per minute were given cardio-selective beta-blocker and for heart rate above 75 (up to 85) beat/min, the best systole phase was used for reconstructing our images

Results: for Evaluation of native coronary arteries, the CTCA showed significant lesions (occlusion or >60 % stenosis) in the native arteries of 13 patients and insignificant lesions in 7 patients.      

Evaluation of CABG (8 arterial grafts); for (LIMA) graft, 83% were patented,   and 17% were narrowed and 100 % of (radial graft) were   patent. For Venous Grafts the study included 10 venous grafts; 70 % were patent, 20% were narrowed and 10 % were totally occluded.

Conclusion: The multi-slice CTCA is now a clinically reliable noninvasive tool that allows the evaluation of the native coronary arteries, the bypass grafts, coronary stents.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Mar 04 2017
Journal Name
Baghdad Science Journal
Measurement and purification of Alanine aminotransferase (ALT) enzyme activity in patients with celiac disease
...Show More Authors

Celiac disease (CD) is the most common genetically - based disease in correlation with food intolerance. The aim of this study is to measure the activity of ALT enzyme and purify enzyme from sera women with celiac disease. Alanine aminotransferase (ALT) activity has been assayed in (30) women serum samples with celiac disease, age range between (20-40) year and (30) serum of healthy women as control group, age range between (22-38) year. In the present study, the mean value of ALT activity was significantly higher in patients with celiac disease than healthy group (p<0.01). The ALT enzyme was partial purified from sera women with celiac disease by dialysis, gel filtration using Sephadex G- 50 and ion exchange chromatography using DEAE- cell

... Show More
Scopus (5)
Scopus Crossref
Publication Date
Sun Sep 03 2017
Journal Name
Baghdad Science Journal
Measurement and purification of Alanine aminotransferase (ALT) enzyme activity in patients with celiac disease
...Show More Authors

Celiac disease (CD) is the most common genetically - based disease in correlation with food intolerance. The aim of this study is to measure the activity of ALT enzyme and purify enzyme from sera women with celiac disease. Alanine aminotransferase (ALT) activity has been assayed in (30) women serum samples with celiac disease, age range between (20-40) year and (30) serum of healthy women as control group, age range between (22-38) year. In the present study, the mean value of ALT activity was significantly higher in patients with celiac disease than healthy group (p<0.01). The ALT enzyme was partial purified from sera women with celiac disease by dialysis, gel filtration using Sephadex G- 50 and ion exchange chr

... Show More
View Publication Preview PDF
Scopus (5)
Scopus Crossref
Publication Date
Wed Sep 01 2021
Journal Name
Iraqi Journal Of Physics
Enhancement of Photoconductive Detector Based on Carbon Nanotubes Decorated with Silver Nanoparticles by Adding Conductive Polymer
...Show More Authors

In this work, wide band range photo detector operating in UV, Visible and IR was fabricated using carbon nanotubes (MWCNTs, SWCNTs) decorated with silver nanoparticles (Ag NPs). Silicon was used as a substrate to deposited CNTs/Ag NPs by the drop casting technique. Polyamide nylon polymer was used to coat CNTs/Ag NPs to enhance the photo-response of the detector. The electro-exploding wire technology was used to synthesize Ag NPs. Good dispersion of silver NPs achieved by a simple chemistry process on the surface of CNTs. The optical, structure and electrical characteristic of CNTs decorated with Ag NPs were characterized by X-Ray diffraction and Field Emission Scanning Electron Microscopy.  X-ray diffra

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Sep 27 2023
Journal Name
Journal Of Optics
Studying the responsivity and detectivity of GO/PSi/n-Si photo detector via drop casting technique
...Show More Authors

View Publication
Scopus (4)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Wed Sep 27 2023
Journal Name
Journal Of Optics
Studying the responsivity and detectivity of GO/PSi/n-Si photo detector via drop casting technique
...Show More Authors

View Publication
Scopus (4)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Tue Mar 12 2019
Journal Name
Al-khwarizmi Engineering Journal
Die Design of Flexible Multi-Point Forming Process
...Show More Authors

Multi-point forming (MPF) is an advanced flexible manufacture technology, and the technology results from the idea that the whole die is separated into small punches that can be adjusted height. This idea is applied to the traditional rigid blank-holder, so flexible blank-holder (FBH) idea can be obtained. In this work, the performance of a multi-point die is investigated with pins in square matrix and suitable blank holder. Each pin in the punch holder can be a significant moved according to the die high and at different load that applied with spring with respect to spring stiffness. The results shows the reduction in setting time with respect to traditional single point incremental forming process that lead to (90%). and also show duri

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Wed Feb 01 2023
Journal Name
International Journal Of Engineering, Ije Transactions B: Applications
Adaptive Polynomial Coding of Multi-Base Hybrid Compression
...Show More Authors

Scopus (5)
Scopus
Publication Date
Tue Apr 01 2014
Journal Name
Journal Of Economics And Administrative Sciences
Multi-dimensional poverty and sustainable human development in Iraq
...Show More Authors

The problem of poverty and deprivation constitute a humanitarian tragedy and its continuation may threaten the political achievements reached by the State. Iraq, in particular, and although he is one of the very rich countries due to availability of huge economic wealth, poverty indicators are still high. In addition, the main factor in the decline in the standard of living due to the weakness of the government's performance in the delivery of public services of water, electricity and sanitation. Thus, the guide for human development has been addressed which express the achievements that the state can be achieved both on a physical level or on the human level, so in order to put appropriate strategies and policies aimed at elimin

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Sep 15 2022
Journal Name
Romanian Neurosurgery
Impact of dome projection on operative steps during clipping of a ruptured pure posteriorly directed posterior communicating artery aneurysms
...Show More Authors

Background: Ruptured posterior communicating artery (PCoA) aneurysms are common; they usually present with subarachnoid haemorrhage (SAH) and oculomotor nerve palsy. The aneurysmal dome projection may influence the safety access and aneurysmal neck clipping. Here, we discuss additional intraoperative steps that may be required to widen the surgical field to ensure safe surgical clipping of a rupture pure posteriorly directed PCoA aneurysm. Case description: A previously healthy 38-year-old male reported sudden severe headache and disturbed level of consciousness with a Glasgow coma scale (GCS) of 13. His initial computed tomography (CT) scan of the head showed SAH in the basal cistern. 3D-constructed CT angiography (CTA) revealed a

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Jun 15 2023
Journal Name
Romanian Neurosurgery
Sellar hematoma as a new potential radiological clue for superior hypophyseal artery aneurysm rupture
...Show More Authors

Background. In cases of spontaneous subarachnoid haemorrhage (SAH) with multiple intracranial aneurysms (MIAs) detected on angiography, some radiological clues assist in determining the site of a ruptured aneurysm which is bleeding is quite beneficial for the selection of the best treatment strategy. Case description. We report a case of a 60 years old patient who presented with spontaneous SAH, sellar hematoma, and three different aneurysms detected in angiography. Although the right Posterior communicating artery (PcomA) aneurysms showed Murphy’s teat on angiography intraoperatively, we discovered that the right superior hypophyseal aneurysm (SHA) was the source of the index bleeding. Both aneurysms were clipped successfully. Co

... Show More
View Publication Preview PDF
Crossref (1)
Crossref