Preferred Language
Articles
/
jkmc-159
Role of Multi-Detector CT Angiography in Assesmente of Athrosclerotic Coronary Artery Disease
...Show More Authors

Background:  Imaging has a critical role in the diagnosis and evaluation of cardiac diseases, beginning with chest radiography and fluoro-scopy and progressing to coronary angio-graphy, echocardiography, nuclear medicine and recently  multidetector computed tomo-graphy (MDCT) as well as magnetic resonance (MR) imaging

Objective: To highlight the role of Multi-detector CT in the evaluation of coronary artery disease and its importance of being noninvasive diagnostic technique.

Methods: A cross sectional study for 20 patients. Patients were asked to fast 6 hours prior to the examination and the patients with heart rates above 65 beats per minute were given cardio-selective beta-blocker and for heart rate above 75 (up to 85) beat/min, the best systole phase was used for reconstructing our images

Results: for Evaluation of native coronary arteries, the CTCA showed significant lesions (occlusion or >60 % stenosis) in the native arteries of 13 patients and insignificant lesions in 7 patients.      

Evaluation of CABG (8 arterial grafts); for (LIMA) graft, 83% were patented,   and 17% were narrowed and 100 % of (radial graft) were   patent. For Venous Grafts the study included 10 venous grafts; 70 % were patent, 20% were narrowed and 10 % were totally occluded.

Conclusion: The multi-slice CTCA is now a clinically reliable noninvasive tool that allows the evaluation of the native coronary arteries, the bypass grafts, coronary stents.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Apr 05 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of the relationship between maxillary sinus floor and maxillary posterior teeth root apices using spiral CT scan
...Show More Authors

Background: The purpose of this study is to investigate the relationship between the roots of the maxillary posterior teeth and the maxillary sinus using spiral computed tomography, and measured the distances between the roots of the maxillary posterior teeth and the sinus floor. Materials and Methods: The sample of the present study was a total of 120 Iraqi subject (60 males & 60 females) aged (20-60) years old, who admitted to spiral Computed Tomography scan unit in AL-Zahraa hospital in AL-Kut city to have Computed Tomography scan of the brain and paranasal sinuses who had complaints of headaches or with suspicion of sinusitis but without pathological findings in maxillary sinuses. From November 2012 to April 2013, CT sagittal reconstruc

... Show More
View Publication Preview PDF
Publication Date
Sun Mar 07 2010
Journal Name
Baghdad Science Journal
Determination the concentration for uranium in phosphrous fertilizers by using nuclear track detector CR-39
...Show More Authors

The aim of this research was to study the concentrations of Uranium in the phosphorus fertilizers using Nuclear track detector (CR-39). Our present investigation is based on the study of 10 types samples for different kinds of phosphorus fertilizers which were available in the local market Some of them were Iraqi made and the others from different countries like, (Iran, Italy, Holland, Lebanon and Jordan) .. The result obtained shows that the Uranium concentration in phosphorus fertilizers samples varies from (3.59ppm) to(2.59ppm). Based on the radioactive concentration of Uranium in the samples all the results obtained between(3.59ppm) in the Iraqi super phosphate to (2.59ppm) in the mixture Iraqi phosphate fertilizer are withi

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Sep 06 2009
Journal Name
Baghdad Science Journal
Radon concentration measurement in soil for some northen Iraqi's regions by using CR-39 detector
...Show More Authors

Concentrations of radon were measured in this study for twenty-four samples of soil distributed in six locations on the north part of Iraq. The radon concentrations in soil samples measured by using alpha-emitters registration that emits from Radon (222Rn) in (CR-39) track detector. The concentrations values were calculated by a comparison with standard samples. The results shows that the radon gas concentrations in Darbandikhan City varies from (16.60-34.04 Bq/m3), Halabja City (16.51-23.32 Bq/m3), Al Sulaimaniya City (17.61-32.25 Bq/m3), Koisnjaq City (22.04-35.65 Bq/m3), Shaqlaua City (21.10-29.10 Bq/m3) and Erbil City (22.30-34.63 Bq/m3). The average radon gas concentration in Al Sulaimaniya and Erbil governorate are (22.30 Bq/m3)

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Apr 24 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Calculation of the Concentrations of Depleted Uranium in The Diyala River Sediment Samples Using The Nuclear Track Detector CR-39
...Show More Authors

   In this study,  depleted uranium concentrations were calculated  in  sediments  Diyala River samples , where 14 samples of sediment along the Diyala River were collected , starting from the Rustumiya area and ending with the Tuwaitha area after its confluence with the River Tigris , using the solid - state nuclear track detectors technique (SSNTDs).        We found that the highest concentration of depleted uranium was in the sample (A-13), and was taken from the Tuwaitha area with the specific activity of the amount (78.1 ± 8.5 Bq/kg ) and the lowest concentration of the depleted uranium was in the sample  (A-7), and was taken from the Azwaip area with  the

... Show More
View Publication Preview PDF
Publication Date
Tue May 11 2021
Journal Name
Research J. Pharm. And Tech
Association of Serum Renal Function Levels with Heart Failure Disease in Iraqi Patients
...Show More Authors

Renal function tests are commonly used in clinical practice to look for renal disease, the most common includes the serum urea, uric acid and creatinine. Heart failure patients have a higher incidence of renal function test abnormalities than individuals who do not have heart failure disease. Fifty subjects of adults (male) were divided in to two groups, 25 subjects (healthy) as control (group1) and 25 subjects with heart failure (group 2). Our results indicate that serum uric acid, urea, and creatinine values were significantly elevated (P≤0.05) in patients group (2) compared with healthy group (1). The results also showed, the effect of age categories on uric acid blood urea nitrogen and creatinine values (P≤0.05) and there were no si

... Show More
Preview PDF
Scopus (2)
Scopus
Publication Date
Thu Jan 17 2019
Journal Name
Energy Procedia
Irradiation of the thin films of MnS with fast neutrons and the possibility of using the new characteristics in optical detector
...Show More Authors

The optical detectors which had been used in medical applications, and especially in radioactive treatments, need to be modified studied for the effects of radiations on them. This study included preparation of the MnS thin films in a way that vacuum thermal evaporation process at room temperature 27°C with thickness (400+-10nm) nm and a sedimentation rate of 0.39nm/sec on glass floors. The thin films prepared as a detector and had to be treated with neutron irradiation to examine the results gained from this process. The results decay X-ray (XRD) showed that all the prepared thin films have a multi-crystalline structure with the dominance of the direction (111), the two samples were irradiated with a neutron irradiation source (241Am-9Be)

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Thu Jan 30 2020
Journal Name
Al-kindy College Medical Journal
Pattern of Congenital Heart Disease In Children Attending Central Teaching Pediatric Hospital, Baghdad
...Show More Authors

Background: Congenital cardiac defects have a wide spectrum of severity in infants. About 30-40% of patients with congenital cardiac defects will be symptomatic in the 1st year of life, while the diagnosis was established in 60% of patients by the 1st month of age.

Objectives: To identify the occurrence of specific types of CHD among hospitalized patients and to evaluate of growth of patients by different congenital heart lesions.

Methods: A retrospective study, done on ninety-six patients (51 male and 45 female) with congenital heart disease (CHD) admitted to central teaching hospital of pediatrics, Baghdad from 1st September 2009 to 30

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Dec 18 2023
Journal Name
Journal Of Iraqi Al-khwarizmi
Fibrewise Multi-Separation Axioms
...Show More Authors

The aim of the research is to apply fibrewise multi-emisssions of the paramount separation axioms of normally topology namely fibrewise multi-T0. spaces, fibrewise multi-T1 spaces, fibrewise multi-R0 spaces, fibrewise multi-Hausdorff spaces, fibrewise multi-functionally Hausdorff spaces, fibrewise multi-regular spaces, fibrewise multi-completely regular spaces, fibrewise multi-normal spaces and fibrewise multi-functionally normal spaces. Also we give many score regarding it.

Preview PDF
Publication Date
Sat Jan 01 2022
Journal Name
Int. J. Nonlinear Anal. Appl.
Fibrewise multi-topological spaces
...Show More Authors

We define and study new ideas of fibrewise topological space on D namely fibrewise multi-topological space on D. We also submit the relevance of fibrewise closed and open topological space on D. Also fibrewise multi-locally sliceable and fibrewise multi-locally section able multi-topological space on D. Furthermore, we propose and prove a number of statements about these ideas.

View Publication Preview PDF
Publication Date
Fri Jul 01 2016
Journal Name
Journal Of Engineering
An Adaptive Multi-Objective Particle Swarm Optimization Algorithm for Multi-Robot Path Planning
...Show More Authors

This paper discusses an optimal path planning algorithm based on an Adaptive Multi-Objective Particle Swarm Optimization Algorithm (AMOPSO) for two case studies. First case, single robot wants to reach a goal in the static environment that contain two obstacles and two danger source. The second one, is improving the ability for five robots to reach the shortest way. The proposed algorithm solves the optimization problems for the first case by finding the minimum distance from initial to goal position and also ensuring that the generated path has a maximum distance from the danger zones. And for the second case, finding the shortest path for every robot and without any collision between them with the shortest time. In ord

... Show More
View Publication Preview PDF