Preferred Language
Articles
/
jkmc-158
Chronic Tennis Elbow Treated by Platelet-Rich Plasma Versus Steroid Injections: A Comparative Study
...Show More Authors

Background: Painful elbow joint over the lateral epicondyle especially with resisted wrist extension are common signs of lateral epicondyle tendinopathy, also called tennis elbow.

Objective: To evaluate the clinical outcome of local platelet rich plasma (PRP) injection in patients with chronic tennis elbow compared with a steroid (Depomedrol 40 mg) injection.

Methods: A total of 88 patients with chronic tennis elbow were treated at Al-Kindy Teaching Hospital and private clinics. All patients had chronic pain for about 24 weeks or more and had failed first line treatment. The patients dividing into two groups, Group A injected with PRP (n = 44), and group B injected with depomedrol 40 mg (n = 44). A good clinical result was demarcated as 25% or more progress on the visual analog scale for pain. All patients followed for 6 months in both group for clinical successful result.

Results: At three months (n = 44), in group A reported a perfection of 58.2% in their pain scores while 49.3% in the group B (N = 44). At 6 months follow up, the group A informed a perfection of 74.3% in their pain scores while 58.4 % in the group B. The local elbow tenderness recording at three months was 37.4% in the group A, while in the group B was 48.4%. At six months, 16.1% versus 30.2%   recounted major elbow tenderness (P = .009) in groups (A and B) respectively.

The clinical improvement rates at three months revealed no changes between both groups while it showed more significant clinically changes in group A ( 87.1%) than in group B (70.1 %) with P value = 0.008 after six months follow up.

Conclusion: No important changes were found at 3 months in both groups, but at 6months, clinical significant perfections in patients treated with PRP group (group A)

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Sep 01 2018
Journal Name
International Journal Of Electrochemical Science
Synthesis and Characterization of AlyCu0.15Zn0.85-yFe2O4 Ferrite Prepared by the Sol-Gel Method
...Show More Authors

View Publication
Scopus (15)
Crossref (15)
Scopus Clarivate Crossref
Publication Date
Sun Jun 06 2010
Journal Name
Baghdad Science Journal
New Method for the Determination of DL-Histidine by FIA and Chemiluminometric Detection
...Show More Authors

This paper present a simple and sensitive method for the determination of DL-Histidine using FIA-Chemiluminometric measurement resulted from oxidation of luminol molecule by hydrogen peroxide in alkaline medium in the presence of DL-Histidine. Using 70?l. sample linear plot with a coefficient of determination 95.79% for (5-60) mmol.L-1 while for a quadratic relation C.O.D = 96.44% for (5-80) mmol.L-1 and found that guadratic plot in more representative. Limit of detection was 31.93 ?g DL-Histidine (S/N = 3), repeatability of measurement was less that 5% (n=6). Positive and negative ion interferances was removed by using minicolume containing ion exchange resin located after injection valve position.

View Publication Preview PDF
Crossref
Publication Date
Wed Jun 18 2014
Journal Name
Desalination And Water Treatment
Removal of zinc from contaminated groundwater by zero-valent iron permeable reactive barrier
...Show More Authors

Scopus (22)
Crossref (24)
Scopus Clarivate Crossref
Publication Date
Mon Mar 01 2010
Journal Name
Basrah Journal Of Science
Hiding Three Images at one image by Using Wavelet Coefficients at Color Image
...Show More Authors

Publication Date
Thu Sep 15 2022
Journal Name
Journal Of Baghdad College Of Dentistry
Determination of Surface Roughness and Accuracy of Alginate Impression Material Disinfected by Immersion
...Show More Authors

Background: This study was conducted to evaluate the surface roughness and dimensional accuracy of commercially obtainable alginate impression material in terms of imbibition after immersion in two different media. Materials and method: Two disinfecting agents, ethanol 70% and povidone-iodine 4%, were used to access the dimensional accuracy and surface roughness of alginate impression material. Weights of specimen discs of alginate impressions were measured before and immediately after immersion to gain a measure of imbibition. For surface roughness, disinfected specimens rectangle was examined before and after disinfection. Results: Minimal changes in weight were observed after disinfection, but a statistically non-significant differenc

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Wed Nov 01 2017
Journal Name
Nano Hybrids And Composites
Photodetection of Near and Middle IR Lasers by f-MWCNTs/Polythiophen Nanocomposite Detector
...Show More Authors

The combination of carbon nanotubes (CNT) and conducting polymers offers an attractive route for the production of novel compounds that can be used in a variety of applications such as sensors, actuators, and molecular scale electronic devices. In this work, functionalized multiwall carbon nanotubes (f-MWCNTs) were added in different load ratios (3 wt%, 5 wt% and 10 wt%) to thiophen (PTh) polymer to procedure PTh/CNTs nanocomposite and deposited on porous silicon substrate by electropolarization. Photoconductive detectors were fabricated using PTh/f-MWCNTs matrix to work in the near region and middle IR regions. These detectors were illuminated by semiconductor laser diode wavelength of 808(nm) and Nd-YAG laser of wavelength 1064 (n

... Show More
View Publication
Crossref (2)
Crossref
Publication Date
Sat Dec 15 2018
Journal Name
Revista De Chimie
Determination of Ethanol in Fermented Broth by Headspace Gas Chromatography using Capillary Column
...Show More Authors

The gas chromatography (GC) method in analytical chemistry is a quick and accurate method to detect volatile components like ethanol. A method for determining volatile components known as Headspace chromatography (HS-GC) was developed along with an internal standard method (ISM) to identify ethanol in fermented broth in the laboratory. The aim of this research is determining the concentration of ethanol in fermented broth using capillary column (ZB-1). This method can analyze ethanol concentrations in the fermented medium broth ranging from 10 to 200 g/L. The validation of this method was done in order to obtain the results to be of high precision and the significant, precision was represented as the relative standard deviation (RSD) which

... Show More
Crossref (4)
Crossref
Publication Date
Mon Mar 23 2020
Journal Name
Baghdad Science Journal
Quantitative Determination of Fluoroquinolones in Contaminated Soils by HPLC with Solid-Phase Extraction
...Show More Authors

This work reports the development of an analytical method for the simultaneous analysis of three fluoroquinolones; ciprofloxacin (CIP), norfloxacin (NOR) and ofloxacin (OFL) in soil matrix. The proposed method was performed by using microwave-assisted extraction (MAE), solid-phase extraction (SPE) for samples purification, and finally the pre-concentrated samples were analyzed by HPLC detector. In this study, various organic solvents were tested to extract the test compounds, and the extraction performance was evaluated by testing various parameters including extraction solvent, solvent volume, extraction time, temperature and number of the extraction cycles. The current method showed a good linearity over the concentration ranging from

... Show More
View Publication Preview PDF
Scopus (6)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Mon Feb 01 2021
Journal Name
Journal Of Engineering
Decolorizing of Malachite Green Dye by Adsorption Using Corn Leaves as Adsorbent Material
...Show More Authors

This paper presents the ability to use cheap adsorbent (corn leaf) for the removal of Malachite Green (MG) dye from its aqueous solution. A batch mode was used to study several factors, dye concentration (50-150) ppm, adsorbent dosage (0.5-2.5) g/L, contact time (1-4) day, pH (2-10), and temperature (30-60)   The results indicated that the removal efficiency increases with the increase of adsorbent dosage and contact time, while inversely proportional to the increase in pH and temperature. An SEM device characterized the adsorbent corn leaves. The adsorption's resulting data were in agreement with Freundlich isotherm according to the regression analysis, and the kinetics data followed pseudo-first-order kinetic with a correlation

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Wed Dec 22 2021
Journal Name
Mathematical Modelling Of Engineering Problems
Forward Kinematic and Jacobian Matrix for the Prosthetic Human Finger Actuated by Links
...Show More Authors

The most important function of a prosthetic hand is their ability to perform tasks in a manner similar to a natural hand, so it is necessary to perform kinematic analysis to determine the performance and the ability of the prosthetic human finger design to work normally and smoothly when it's drive by two sets of links that embedded in its structure and pulled by a servomotor, so the Denvit-Hartenberg method was used to analyse the forward kinematics for the prosthetic finger joints to deduction the trajectory of the fingertip and the velocity of the joints was computed by using the Jacobian matrix. The prosthetic finger was modelled by the Solidwork - 2018 program and the results of kinematics were verified using MATLAB. The analys

... Show More
View Publication Preview PDF
Crossref