Accuracy of Fine Needle Aspiration Biopsy (F.N.A.B) in Diagnosis of Breast Lump
...Show More Authors

Background: Breast cancer is the first one among Iraqi females. Most of them present later for diagnosis. Early detection center in tertiary hospital practice uses FNAB for early diagnosis. Publications on accuracy of this detection are scarce.

Objective:  To test the accuracy of FNAB in breast lump diagnosis.

Methods: Diagnostic test accuracy study, on 204 women with breast lump, attending the oncology department in 2017.

Results: Fine-needle aspiration biopsy diagnosis of histologically malignant cases were, malignant in 89 (87.3%), suspicious of malignancy in 5 (4.9%), and benign in 4 (3.9%). Complete sensitivity was 87.3%, and specificity was 100%, with 12.7% false negative results and no false positive cases. The accuracy was 94%.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Jan 01 2022
Journal Name
Journal Of Population Therapeutics And Clinical Pharmacology
Accuracy of Office Hysteroscopy in Diagnosis of Endometrial Pathologies Compared to Ultrasound and Histopathology in Baghdad Teaching Hospital
...Show More Authors

Background: Menstrual problems with all manifestations ranging from life-threatening bleeding to amen- orrhea are considered patterns of abnormal uterine bleeding (AUB), which is until now a popular reason for referral to the gynaecologic clinic and requires a special diagnostic tool. Objective: To assess the accuracy of hysteroscopy in diagnosing endometrial pathologies and to compare it with sonographic and histopathologic reports. Patients and Methods: A prospective study conducted in the Baghdad Teaching Hospital on 60 Iraqi females having varying complaints from abnormal uterine bleeding in pre- and post-menopausal women, infertility, and chronic pelvic pain with normal or abnormal ultrasound findings. Office hysteroscopy was done and

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Sun May 12 2019
Journal Name
Journal Of The Faculty Of Medicine Baghdad
The accuracy of pelvic magnetic resonance imaging in the diagnosis of ovarian malignancy in Iraqi patients in comparison with histopathology
...Show More Authors

Background: Ovarian malignancy is considered to score the highest fatality among women due to lack of significant symptoms. Early diagnosis and treatment lead to good prognosis. Magnetic resonance imaging (MRI) plays a major role in the diagnosis by detecting the lesions and assessing their appearance and consistency.

Objective: To determine the accuracy of MRI in the diagnosis of ovarian malignancy and comparing this to histopathology as a gold standard test.

Patients and methods: A follow up study was conducted in the MRI unit of the Radiology Department in Baghdad Teaching Hospital / Baghdad Medical City Complex during the period from 1st of February to 31

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Jul 01 2019
Journal Name
International Journal Of Medical Research & Health Sciences
Assessing the Period between Diagnosis of Breast Cancer and Surgical Treatment among Mastectomized Female Patients in Iraq
...Show More Authors

Introduction: Breast cancer is the most common cancer and the major cause of cancer related deaths among Iraqi women. Due to the relatively late detection of breast cancer, the majority of the patients are still treated by modified radicle mastectomy. Aim: To assess the time lag between diagnosis of breast cancer and mastectomy among Iraqi patients; correlating the findings with other clinicopathological characteristics of the disease. Patients and methods: This retrospective study enrolled 226 Iraqi female patients who were diagnosed with breast cancer. Data were registered on the exact time period between signing the histopathological report and the surgical treatment. Other recorded variables included the age of the patients, their level

... Show More
View Publication Preview PDF
Publication Date
Tue Jan 09 2018
Journal Name
International Journal Of Medical Research & Health Sciences
Assessing the Period between Diagnosis of Breast Cancer and Surgical Treatment among Mastectomized Female Patients in Iraq
...Show More Authors

Introduction: Breast cancer is the most common cancer and the major cause of cancer related deaths among Iraqi women. Due to the relatively late detection of breast cancer, the majority of the patients are still treated by modified radicle mastectomy. Aim: To assess the time lag between diagnosis of breast cancer and mastectomy among Iraqi patients; correlating the findings with other clinicopathological characteristics of the disease. Patients and methods: This retrospective study enrolled 226 Iraqi female patients who were diagnosed with breast cancer. Data were registered on the exact time period between signing the histopathological report and the surgical treatment. Other recorded variables included the age of the patients, their level

... Show More
Preview PDF
Publication Date
Wed Dec 14 2016
Journal Name
Journal Of Baghdad College Of Dentistry
Surgical Biopsy in Cervical Lymphadenopathy
...Show More Authors

Background: Cervical lymph nodes are the most frequently enlarged and biopsied of all the peripheral lymph nodes and in most of the cases the enlargement results from benign infectious causes, however, the presence of cervical lymphadenopathy (LAP) requires accurate diagnosis to exclude more serious causes. The aim of this study was to analyze cases of Iraqi patients presenting with cervical LAP who underwent surgical lymph node biopsy to establish accurate diagnosis. Materials and Methods: This retrospective study included 25 patients who presented with cervical LAP for whom surgical biopsy was performed to establish a definitive diagnosis. The investigated data included the demographic and clinical parameters in addition to the final his

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue May 01 2012
Journal Name
Iraqi Journal Of Physics
Argon plasma needle source
...Show More Authors

Non thermal argon plasma needle at atmospheric pressure was generated. The experimental set up is based on very simple and low cost electric components that generate electrical field sufficiently high at the electrodes to ionize various gases, which flow at atmospheric pressure. The high d.c power supply is 7.5kV peak to peak, the frequency of the electrical field is 28kHz, and the plasma power less than 15W. The plasma is generated using only one electrode. In the present work the voltage and current discharge waveform are measured. Also the temperature of the working Ar gas at different gas flow and distances from the plasma electrode tip was recorded

View Publication Preview PDF
Publication Date
Tue Sep 19 2017
Journal Name
Journal Of Neoplasm
The stage of breast cancer at the time of diagnosis: correlation with the clinicopathological findings among Iraqi patients
...Show More Authors

Background: Breast cancer is the most frequently diagnosed malignancy and the second leading cause of mortality among women in Iraq forming 23% of cancer related deaths. The low survival from the disease is a direct consequence to the advanced stages at diagnoses. Aim: To document the composite stage of breast cancer among Iraqi patients at the time of diagnosis; correlating the observed findings with other clinical and pathological parameters at presentation. Patients and Methods: A retrospective study enrolling the clinical and pathological characteristics of 603 Iraqi female patients diagnosed with breast cancer. The composite stage of breast cancer was determined according to UICC TNM Classification System of Breast Cancer and the Ameri

... Show More
View Publication Preview PDF
Crossref (9)
Crossref
Publication Date
Sat Jun 01 2013
Journal Name
Journal Of The College Of Languages (jcl)
Gracq : aspiration vers une écriture picturale
...Show More Authors

Entre le dessin et l’écriture, le rapport est très fort, les deux techniques sont par excellence des moyens d’expression de l’homme sur la toile ou la page. Ainsi les genres romanesques et poétiques connaissent-ils en peinture depuis longtemps une bonne source d’inspiration : des poètes (comme Baudelaire et René Char) et des romanciers (Balzac et Proust) ont, chacun à leur manière, réfléchi et interrogé les œuvres des peintres. La description d’un tableau demeure très fréquente non seulement dans la littérature moderne, voire dans celle de l’époque classique ; en revanche, le Moyen Age connaît la pratique de l’illust

... Show More
View Publication Preview PDF
Publication Date
Sun Feb 03 2019
Journal Name
Iraqi Journal Of Physics
Influence of non-thermal argon plasma needle on blood coagulation
...Show More Authors

Non-thermal argon plasma needle at atmospheric pressure was
constructed. The experimental setup was based on a simple and low
cost electric component that generates a sufficiently high electric
field at the electrodes to ionize the argon gas which flow at
atmospheric pressure. A high AC power supply was used with 1.1
kV and 19.57 kHz. Non-thermal Argon plasma used on blood
samples to show the ability of non-thermal plasma to promote blood
coagulation. Three tests have been done to show the ability of plasma
to coagulate both normal and anti-coagulant blood. Each blood
sample has been treated for varying time from 20sec. to 180sec. at
different distances. The results of the current study showed that the
co

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Dec 01 2021
Journal Name
Iraqi Journal Of Science
The Study of Electrical Description for Non-Thermal Plasma Needle System
...Show More Authors

In this research, a non-thermal plasma system was designed and a non-thermal plasma needle was manufactured for argon gas operating at normal atmospheric pressure. The electrical description of this system studied by using two different values of voltages (4.9,8) kV. Where the results showed the small amount of electrical current consumed by the system of plasma needle up to several microns of amps, and the value of the electrical current increase with the increasing gas flow, as well as the results, showed that happen a breakdown voltage at (8) kV when gas flow (4 l/min) causing a slight decrease in the electrical current value.