Preferred Language
Articles
/
jkmc-132
Urinary Tract Infection Risk Assessment By Non- Thermal Plasma In Iraqis Patients
...Show More Authors

Background: In the present study used device jet plasma needle with atmospheric pressure which  generates non thermal plasma jet to measure treatment potent with plasma against pathogenic bacteria  founded  in UTI  was inactivated with plasma at 10 sec,

Objective:. This work included the application of the plasma produced from the system in the field of bacterial sterilization , where sample of Gram- negative bacteria (Escherichia coli) were exposed to intervals (1-10)second . Midstream Urine samples swabs were obtained from patients with urinary tract infections.

Type of the study: Cross -sectional study.

Methods: The work were used in this study  obtained from studying 100 urine samples, the age of patients ranged between 10 years to 60 years. They were 60 females and 40 males. These samples were cultured on culture media to isolate bacterial colonies .After that, bacteria were identified by means of highly specific investigations Escherichia coli, plasma needle treatment is applied on bacteria through sterilization,  and adhesion.

Results : It was found that the percentage of the killing of Gram-negative bacteria (E.coli) was 100% at (10) second, also decreasing bacterial adhesion on epithelial cells, where  numbers  adhesion bacterial with uroepithelial cells  decrease after treatment with plasma needle .

Conclusion : From this work, it has been observed that applied voltage ,distance between plasma needle and treatment model as well as  time  treatment effect on inactivation bacteria and sterilization ,also it effect on decreasing bacterial adhesion on epithelial cells, where  numbers  adhesion bacterial with uroepithelial cells  decrease after treatment with plasma needle .

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Mar 06 2011
Journal Name
Baghdad Science Journal
Study of opacity broadening in spectral lines for helium like ions in aluminum plasma which produced by laser
...Show More Authors

A theoretical analysis studied was performed to study the opacity broadening of spectral lines emitted from aluminum plasma produced by Nd-YLF laser. The plasma density was in the range 1028-1026 )) m-3 with length of plasma about ?300) m) , the opacity was studied as function of plasma density & principle quantum number. The results show that the opacity broadening increases as plasma density increases & decreases with the spacing between energy levels of emission spectral line.

View Publication Preview PDF
Crossref
Publication Date
Thu Mar 30 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Study the Prevalence of Helicobacter pylori Infection by Different Diagnostic Methods
...Show More Authors

A total of 41 patients with gastro duodenal symptoms (show signs of inflammation with or without duodenal ulcer) . 21 males (51.2%) and 20 female (48.8%) with an average age 0f  (20 – 80) years old under  going gastrointestinal endoscopy at Baghdad teaching hospital in internal disease clinical laboratory , between (February – June)  2009 . Biopsies specimen of antrum , gastric fundus ,& duodenal bulb were examined by the following methods (rapid urease test , Giemsa stain section to detect bacteria , & Haematoxilin and Eosin stained section for pathological study which are considered the gold standard methods , sera or plasma from these patients were tested by immunochromotography (ICM),serological m

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Jul 04 2022
Journal Name
International Journal Of Health Sciences
The association between plasma IL-6 levels and several thalassemia-related clinical features in Iraqi patients
...Show More Authors

The present study was set to investigate the potential association between the level of Interleukin-6 (IL-6), as a key component of the pro-inflammatory response, with different thalassemia’s biological and clinical features. For this purpose, one hundred fifty blood samples were collected from 100 beta-thalassemia patients, who attended the Genetic Hematology Centre at Ibn Al- Baladi Hospital in Baghdad, Iraq, and 50 healthy subjects who were employed as a control group. IL-6 levels were estimated using an ELISA Kit, whereas other thalassemia-related clinical features (such as HbA, HbF, ferritin, blood transfusions, splenectomy status, and the history of frequent infection) were additionally assessed. The results of the present s

... Show More
View Publication
Crossref
Publication Date
Mon Aug 25 2025
Journal Name
Journal Of Systems Science And Mathematical Sciences
SCREENING TESTS FOR DISEASE RISK HAPLOTYPE SEGMENTS IN GENOME BY USE OF PERMUTATION
...Show More Authors

The haplotype association analysis has been proposed to capture the collective behavior of sets of variants by testing the association of each set instead of individual variants with the disease.Such an analysis typically involves a list of unphased multiple-locus genotypes with potentially sparse frequencies in cases and controls.It starts with inferring haplotypes from genotypes followed by a haplotype co-classification and marginal screening for disease-associated haplotypes.Unfortunately,phasing uncertainty may have a strong effects on the haplotype co-classification and therefore on the accuracy of predicting risk haplotypes.Here,to address the issue,we propose an alternative approach:In Stage 1,we select potential risk genotypes inste

... Show More
View Publication
Publication Date
Wed Jan 01 2020
Journal Name
Technologies And Materials For Renewable Energy, Environment And Sustainability: Tmrees20
Effect gold nanoparticles generated by cold plasma for mineral blood
...Show More Authors

In the present study, gold nanoparticles (AuNPs) were prepared using a simple low cost method synthesized cold plasma at different exposure time . The nanoparticles were characterized using UV-Visible spectra, X-ray diffraction (XRD). The prepared AuNPs showed surface Plasmon resonance centered at 530, 540,and 533 nm. The XRD pattern showed that the strong intense peaks indicate crystalline nature and face centered cubic structure of gold nanoparticles for all samples were prepared .The average crystallite size of the AuNPs was 20-40 nm. Morphology of the AuNPs were carried out using FESEM. Observations show that the AuNPs synthesized we well dispersed with and particle sizes ranging from 9 to 31 nm with spherical shapes which are cle

... Show More
View Publication
Scopus (3)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Sat Apr 01 2023
Journal Name
Kuwait Journal Of Science
Evaluate the argon plasma jet parameters by optical emission spectroscopy
...Show More Authors

View Publication Preview PDF
Scopus (12)
Crossref (10)
Scopus Clarivate Crossref
Publication Date
Sat Mar 02 2019
Journal Name
Iraqi Rjounal Of Science
The immunohistochemical assessment of Muc5ac in patients with gastric carcinoma (Gc) in Iraq
...Show More Authors

The expression of MUC5AC has been associated with the loss of the differentiation, TNM system, and nodal metastasis, in many cancers including gastric carcinoma (GC).Objective: To evaluate whether the MUC5AC could be used as a predictor in patients with GC and to assess the correlation between the expression of MUC5AC& the clinicpathological parameters as age, sex, histopathological subtypes, grade and stage of the tumor. This is a retrospective study conducted on 60 randomly selected patients (30 normal vs 30 GC), at the Pathology Department of the Gastroenterology and Hepatology Teaching Hospital&some private laboratories. They were collected and diagnosed during the period 2014-2018. Histological sections were stained with H&E and IHC st

... Show More
Preview PDF
Publication Date
Thu Dec 01 2011
Journal Name
Iraqi Journal Of Physics
Surface Modification of Ti-6Al-4V Alloy by Glow Discharge-Plasma Nitriding
...Show More Authors

Titanium alloy (Ti-6Al-4V) samples were nitrided in low pressure (1.3, 3 mbar) dc-glow discharge plasmas of nitrogen. The treating time was 5, 10 and 15 hour and the temperatures range of the samples during the nitriding process was close to 800oC. The obtained microstructures of the nitride layers were studied by x-ray diffraction and optical microscopy. The ε –Ti2N, ζ-Ti3N3-x and η-Ti3N2-x.phases were formed and addition to the solid solution of nitrogen in titanium, α (Ti,N). Micro hardness measurements exhibit an increment for the Ti-alloy specimens which nitrided at 800oC for 10 and 15h.Corrosion measurements were obtained for the Ti-6Al-4V alloy in Ringer solution after plasma nitriding. The clear improving in the corrosion r

... Show More
View Publication Preview PDF
Publication Date
Sun Jan 01 2017
Journal Name
Indian Journal Of Pathology And Microbiology
Assessment of topoisomerase II-alpha gene status by dual color chromogenic in situ hybridization in a set of Iraqi patients with invasive breast carcinoma
...Show More Authors

Abstract Background: The human epidermal growth factor receptor 2(HER2) proto-oncogene is overexpressed or amplified in approximately 15%-25% of invasive breast cancers. Approximately 35% of HER2-amplified breast cancers have coamplification of the topoisomerase II-alpha (TOP2A) gene encoding an enzyme that is a major target of anthracyclines. Hence, the determination of genetic alteration (amplification or deletion) of both genes is considered as an important predictive factor that determines the response of breast cancer patients to treatment. The aims of this study are to determinate TOP2A status gene amplification in a set of Iraqi patients with breast cancer that have had an equivocal (2+) and positive HER2/neu by immunohistochemistry

... Show More
View Publication
Scopus (2)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Sun Mar 04 2018
Journal Name
Baghdad Science Journal
Effects of Gas Flow on Spectral Properties of Plasma Jet Induced by Microwave
...Show More Authors

In this paper, a construction microwave induced plasma jet(MIPJ) system was used to produce a non-thermal plasma jet at atmospheric pressure, at standard frequency of 2.45 GHz and microwave power of 800 W. The working gas Argon (Ar) was supplied to flow through the torch with adjustable flow rate using flow meter regulator. The influence of the MIPJ parameters such as applied voltage and argon gas flow rate on macroscopic microwave plasma parameters were studied. The macroscopic parameters results show increasing of microwave plasma jet length with increasing of applied voltage, argon gas flow rate where the plasma jet length exceed 12 cm as maximum value. While the increasing of argon gas flow rate will cause increasing into the ar

... Show More
View Publication Preview PDF
Scopus (16)
Crossref (4)
Scopus Clarivate Crossref