Preferred Language
Articles
/
jkmc-1218
Radiological Significance of Shear-Wave Elastography Technique for Evaluation of Solid Breast Masses with Histopathological Correlation
...Show More Authors

Background: Although various imaging modalities are available for evaluating suspicious breast lesions, ultrasound-based Shear-Wave Elastography (SWE) is an advanced, non-invasive technique complementary to grayscale sonography. This technique evaluates the elasticity of a specific tissue by applying sonic pressure to that tissue.

Objective: The aim is to assess the role of SWE in evaluating solid breast masses in correlation to histopathological study results.

Subjects and Methods: This prospective study was done in a tertiary care teaching hospital from September 2019 to August 2020. A study population of 50 women aged 18 years or above with an ultrasonographic (USG) diagnosis of solid breast masses was included.

Results: A significantly higher value of SWE elasticity ratio (E-mean) was observed in malignant tumors than in benign tumors (p <0.0001).  The area-under-curve (AUC) for the BI-RADS 4 lesions was 0.522 (95% CI, 0.343-0.701) with an E-ratio cut-off score of 85.25, the sensitivity and specificity were 50% for diagnosing malignant tumors, whereas AUC for the HPE study was 1.000 (95% CI, 1.000-1.000) with an E-ratio cut-off score of 134.25; both the sensitivity and specificity were 100% for diagnosing malignant tumors.

Conclusions: Carcinoma breast is one of the most prevalent cancers globally. The most common benign tumor of the breast is a fibroadenoma, whereas Invasive Ductal Carcinoma is the most common malignant breast mass. A well-defined SWE elasticity ratio range might help predict the aggressiveness of breast tumors. SWE's correlation with BI-RADS in suspicious lesions adds to histopathology's advantage in distinguishing malignant tumors from benign ones.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue May 01 2018
Journal Name
Iop Conference Series: Materials Science And Engineering
Evaluation of Electromagnetic Near-Field Measurement Technique as Non-Destructive Testing for Composite Structures
...Show More Authors

View Publication
Scopus (3)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Thu Jan 01 2015
Journal Name
International Journal Of Science And Research (ijsr
Interaction of Alpha Particles with Breast Tissue
...Show More Authors

As modern radiotherapy technology advances, radiation dose and dose distribution have improved significantly. As part of a natural evolution, there has recently been renewed interest in therapy, particularly in the use of heavy charged particles, because these types of radiation serve theoretical advantages in all biological and physical aspects. The interactions of alpha particle with matter were studied and the stopping powers of alpha particle with Breast Tissue were calculated by using Beth-Bloch equation, Zeigler's formula and SRIM software, also the Range and Liner Energy Transfer (LET) and Breast Thickness As well as Dose and Dose equivalent for this particle were calculated by using Mat lab language for (0.01-200) MeV alpha ene

... Show More
Publication Date
Thu Aug 21 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The Clinical Approach and Treatment of Benign and Malignant Parotid Masses
...Show More Authors

Background: Parotid gland tumors account for 80% of all salivary gland neoplasms, 20% of these are malignant, but in daily clinical practice most parotid masses are operated on before obtaining the final histological diagnosis. This clinical setting further complicates the critical point of parotid surgery, which is the management of the facial nerve. Materials and methods: 45 patients underwent parotidectomy for benign and malignant neoplasms. A complete history is collected from the patients with the duration and the site of the tumor, the facial nerve examined and its associations, a medical consultation done for opinion and management. Clinical examination with facial nerve was mandatory to avoid any mistakes that may occur. The most si

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Dec 01 2023
Journal Name
Experimental And Applied Biomedical Research (eabr)
Correlation Between Ultrasound BI-Rads 4 Breast Lesions and Fine Needle Cytology Categories in a Sample of Iraqi Female Patients
...Show More Authors

Breast cancer is the most common malignancy in female and the most registered cause of women’s mortality worldwide. BI-RADS 4 breast lesions are associated with an exceptionally high rate of benign breast pathology and breast cancer, so BI-RADS 4 is subdivided into 4A, 4B and 4C to standardize the risk estimation of breast lesions. The aim of the study: to evaluate the correlation between BI-RADS 4 subdivisions 4A, 4B & 4C and the categories of reporting FNA cytology results. A case series study was conducted in the Oncology Teaching Hospital in Baghdad from September 2018 to September 2019. Included patients had suspicious breast findings and given BI-RADS 4 (4A, 4B, or 4C) in the radiological report accordingly. Fine needle aspirati

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Sat Jun 01 2019
Journal Name
2019 International Symposium On Networks, Computers And Communications (isncc)
An Interference Mitigation Scheme for Millimetre Wave Heterogeneous Cloud Radio Access Network with Dynamic RRH Clustering
...Show More Authors

View Publication
Crossref (2)
Crossref
Publication Date
Tue Jul 20 2021
Journal Name
Materials Science Forum
Preparation of Solid-Super Acidic Catalyst with Improvement Physical Properties
...Show More Authors

Sulphated zirconia (SZ) is one of the most important solid acid catalysts was synthesize at different operating conditions, different calcination temperature and sulfonating time has been used. The prepared catalyst was distinguished by X-ray Diffraction (XRD), particle size and morphology of catalyst were checked by atomic force microscopy (AFM) and scanning electron microscopy (SEM) respectively, in addition to analysis by (DTA) Differential thermally and Energy Dispersive X-Ray (EDX). Finally, the N2 adsorption-desorption was used to measure the surface area (BET) and pore volume. High degree of tetragonal crystallinity was obtained 90 %, and surface area of 169 m2/g and pore volume of 0.39 cm3g-1 at 600°C calcination temperature for 3

... Show More
Crossref (4)
Crossref
Publication Date
Thu Jan 24 2019
Journal Name
Al-kindy College Medical Journal
Role of MRI diffusion weighted imaging in differentiation between benign and malignant ovarian masses
...Show More Authors

Background: Characterization of the ovarian masses preoperatively is important to inform the surgeon about the possible management strategies. MRI may be of great help in identifying malignant lesion before surgery. Diffusion Weighted Imaging (DWI) is a sensitive method for changes in proton of water mobility caused by pathological alteration of tissue cellularity, cellular membrane integrity, extracellular space perfusion, and fluid viscosity.

Objective: to study the diagnostic accuracy of DWI in differentiation between benign and malignant ovarian masses.

Type of the study:Cross-sectional study.

Methods: this study included  53with complex

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Jul 26 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Formulation and Evaluation of Fast Dissolving Tablets of Taste-Masked Ondansetron Hydrochloride by Solid Dispersion
...Show More Authors

Ondansetron hydrochloride (ONH) is a very bitter, potent antiemetic drug used for the treatment and/or prophylaxis of chemotherapy or radiotherapy or postoperative induced emesis. The objective of this study is to formulate and evaluate of taste masked fast dissolving tablet (FDTs) of ONH to increase patient compliance.

 ONH taste masked granules were prepared by solid dispersion technique using Eudragit E100 polymer as an inert carrier. Solvent evaporation and fusion melting methods were used for such preparation.

Completely taste masking with zero release of drug in phosphate buffer pH 6.8was obtained from granules prepared by solvent evaporation method using drug: polymer ratio of 1:2, from which four formulas pas

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Wed Feb 01 2023
Journal Name
Baghdad Science Journal
Revision of some Biomarkers with Cytokines in Breast Cancer
...Show More Authors

Breast cancer is the most repeatedly detected cancer category and the second reason cause of cancer-linked deaths among women worldwide. Tumor bio-indictor is a term utilized to describe possible indicators for carcinoma diagnosis, development and progression. The goal of this study is to evaluate part of some cytokines and biomarkers for both serum and saliva samples in breast cancer then estimate their potential value in the early diagnosis of breast cancer by doing more researches in saliva, and utilizing saliva instead of blood (serum and plasma) in sample collection from patients. Serum and salivary samples were taken from 72 patients with breast cancer and 45 healthy controls, in order to investigate the following

... Show More
View Publication Preview PDF
Scopus (5)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Fri May 10 2019
Journal Name
Research Journal Of Chemistry And Environment
Solid Phase Extraction of Theophylline in Aqueous Solutions by Modified Magnetic Iron Oxide Nanoparticles as an Extractor Material and Spectrophotometry Technique for the Determination
...Show More Authors

new, simple and fast solid-phase extraction method for separation and preconcentration of trace theophylline in aqueous solutions was developed using magnetite nanoparticles (MIONPs) coated with aluminium oxide (AMIONPs) and modified with palmitate (P) as an extractor (P@AMIONPs). It has shown that the developed method has a fast absorbent rate of the theophylline at room temperature. The parameters that affect the absorbent of theophylline in the aqueous solutions have been investigated such as the amount of magnetite nanoparticle, pH, standing time and the volume, concentration of desorption solution. The linear range, limit of quantification (LOQ) and limit of detection (LOD) for the determination of theophylline were 0.05-2.450 μg mL-

... Show More
View Publication