Preferred Language
Articles
/
jkmc-116
Stethoscope as potential occupational hazards for intra hospital carries of pathogenic microorganisms
...Show More Authors

Background: The stethoscope is a tool that doctors use daily in the examination of patients and  it  can take part in the transmission of health care-associated infections. In a single day it may come in direct contact with multiple patients and the intra hospital environment  may be contaminated by various type of bacteria and possibly transmit to others.

Objective:- The study was to know the attitude and knowledge about   the stethoscope hygiene behavior among physicians  and to determine the types of  bacterial agents that can contaminate stethoscopes.

Type of the study: The study was a cross-sectional study

Methods:-  It was conducted from 1st of July to end of October 2014 at AL-Emmamain Alkadhomain Medical City in which a convenient sample of 150 physicians  were included. A semi constructed questionnaire was used to collect demographic data and hygiene practice among participants. Specimen was collected using moisten sterile cotton swab and then cultured following standard microbiological techniques.

 The results:- showed a total of 121 (80.6%) of the stethoscopes had bacterial contamination only 29(19.40%) had negative cultures. There is statistically significant association between stethoscope contamination and frequency of cleaning it. Of the studied group only 26 subjects (17.3%) received education regarding stethoscope cleaning.

Conclusion:-There was evidence that bacteria can transfer from the skin of the patient to the stethoscope and from the stethoscope to the skin and there was poor education and assessing cleaning practices of stethoscopes.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Aug 01 2022
Journal Name
Baghdad Science Journal
Water Temperature Effect on Hardness and Flexural Strength of (PMMA/TiO2 NPs) for Dental Applications
...Show More Authors

PMMA (Poly methyl methacrylate) is considered one of the most commonly used materials in denture base fabrication due to its ideal properties. Although, a major problem with this resin is the frequent fractures due to heavy chewing forces which lead to early crack and fracture in clinical use. The addition of nanoparticles as filler performed in this study to enhance its selected mechanical properties. The Nano-additive effect investigated in normal circumstances and under a different temperature during water exposure. First, tests applied on the prepared samples at room temperature and then after exposure to water bath at (20, 40, 60) C° respectively. SEM, PSD, EDX were utilized for samples evaluation in this study. Flexural

... Show More
View Publication Preview PDF
Scopus (14)
Crossref (9)
Scopus Clarivate Crossref
Publication Date
Wed Jan 01 2025
Journal Name
Aip Conference Proceedings
Synthesis and evaluation of chalcone derivatives for antimicrobial and antioxidant activities using microwave-assisted methodology
...Show More Authors

View Publication
Scopus (2)
Scopus Crossref
Publication Date
Thu Mar 01 2018
Journal Name
Ieee Systems Journal
A Comprehensive Survey of the Current Trends and Extensions for the Proxy Mobile IPv6 Protocol
...Show More Authors

View Publication
Scopus (20)
Crossref (18)
Scopus Clarivate Crossref
Publication Date
Mon May 01 2023
Journal Name
Ain Shams Engineering Journal
Neural network modeling of rutting performance for sustainable asphalt mixtures modified by industrial waste alumina
...Show More Authors

Scopus (21)
Crossref (12)
Scopus Clarivate Crossref
Publication Date
Sun Sep 05 2010
Journal Name
Baghdad Science Journal
Effect of Hydroxyapatite Coatings on Corrosion Behavior for Biotype 316L SS Used in Orthopaedic Applications
...Show More Authors

Electrochemical corrosion of hydroxyapatite (HAP) coated performance depends on various parameters like applied potential, time, thickness and sintering temperature. Thus, the optimum parameters required for the development of stable HAP coatings was found by using electrophoretic deposition (EPD) technique. This study discusses the results obtained from open circuit potential-time measurements (OCP-time), potentiodynamic polarisation and immersion tests for all alloy samples done under varying experimental conditions, so that the optimum coating parameters can be established. The ageing studies of the coated samples were carried out by immersing them in Ringer’s solution for a period of 30 days indicates the importance of stable HAP c

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Feb 17 2026
Journal Name
Journal Of Physical Education
Using Agility Exercises For Developing Some Refereeing Skills Of First Class Assistant Referees In Baghdad
...Show More Authors

Agility is considered an important motor ability for assistant referees and it is vital for passing modern tests issued in September 2016. The researcher used the experimental method. The subjects were (10) referees; four of them for pilot study. The experimental group followed the exercises designed by the while the controlling group used the traditional exercises followed by the refereeing committee. All referees were tested the standardized agility test issued by the FIFA. The researchers concluded that agility plays a vital role in developing some refereeing skill. Finally they recommend developing agility for improving refereeing skills.

View Publication
Publication Date
Sat Jan 01 2022
Journal Name
The 2nd Universitas Lampung International Conference On Science, Technology, And Environment (ulicoste) 2021
Investigation of the vibrational spectral and electronic properties for ZnxBe7-xO7 wurtzoid via DFT approximation
...Show More Authors

View Publication
Scopus (1)
Scopus Crossref
Publication Date
Sun Jun 05 2016
Journal Name
Baghdad Science Journal
Flame Atomic Emission and Colorimetric Methods for the Determination of Cephalexin Monohydrate in Pharmaceutical Preparations
...Show More Authors

We propose two simple, rapid, and convenient spectrophotometric methods which are described for the determination of cephalexin in bulk and its pharmaceutical preparations. They are based on the measurement of the flame atomic emission of potassium ion (in the first method) and colorimetric determination of the green colored solution at 610 nm formed after the reaction of cephalexin with potassium permanganate as an oxidant agent (in the second method) in basic medium. The working conditions of the methods are investigated and optimized. Beer's law plot shows a good correlation in the concentration range of 5-40?g ml-1. The detection limits are 2.573,2.814 ?g ml-1 for the flame emission photometric method and 1.844,2.016 ?g ml-1 for colo

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Dec 05 2024
Journal Name
Iraqi Journal Of Applied Physics
Synthesis and Characterization of Zinc Cobalt Ferrite Embedded into PAN Nanofibers for Humidity Sensing Applications
...Show More Authors

In this work, composite materials were prepared by mixing different concentrations of ferrites with polyacrylonitrile (PAN) polymer. Using the electrospinning technique, these composites were deposited on a p-type silicon wafer. The prepared samples demonstrated nanofibers in both pure PAN polymers and their composites with ferrite. Prior to examining the humidity sensing effectiveness with a percentage of relative humidity at a frequency of 10 kHz, based on ambient temperature and a relative humidity range of 50–100%, the composite nanofibers demonstrated stronger humidity sensing compared to the pure PAN nanofibers, which demonstrated a powerful resistance response. More precisely, the PAN@ferrite nanocomposite showed a broad adsorption

... Show More
Scopus
Publication Date
Sat Jul 28 2018
Journal Name
Journal Of Engineering
Experimental Investigation for the Removal of Toxic Gases from Vehicle Exhaust using Non-Thermal Plasma
...Show More Authors

In this study, the use of non-thermal plasma theory to remove toxic gases emitted from a vehicle was experimentally investigated. A non-thermal plasma reactor was constructed in the form of a cylindrical tube made of Pyrex glass. Two stainless steel rods were placed inside the tube to generate electric discharge and plasma condition, by connecting with a high voltage power supply (up to 40 kV). The reactor was used to remove the contaminants of a 1.25-liter 4-cylinder engine at ambient conditions. Several tests have been carried out for a ranging speed from 750 to 4,500 rpm of the engine and varying voltages from 0 to 32 kV. The gases entering the reactor were examined by a gas analyzer and the gases concentration ratio

... Show More
View Publication Preview PDF
Crossref (4)
Crossref