Preferred Language
Articles
/
jkmc-116
Stethoscope as potential occupational hazards for intra hospital carries of pathogenic microorganisms
...Show More Authors

Background: The stethoscope is a tool that doctors use daily in the examination of patients and  it  can take part in the transmission of health care-associated infections. In a single day it may come in direct contact with multiple patients and the intra hospital environment  may be contaminated by various type of bacteria and possibly transmit to others.

Objective:- The study was to know the attitude and knowledge about   the stethoscope hygiene behavior among physicians  and to determine the types of  bacterial agents that can contaminate stethoscopes.

Type of the study: The study was a cross-sectional study

Methods:-  It was conducted from 1st of July to end of October 2014 at AL-Emmamain Alkadhomain Medical City in which a convenient sample of 150 physicians  were included. A semi constructed questionnaire was used to collect demographic data and hygiene practice among participants. Specimen was collected using moisten sterile cotton swab and then cultured following standard microbiological techniques.

 The results:- showed a total of 121 (80.6%) of the stethoscopes had bacterial contamination only 29(19.40%) had negative cultures. There is statistically significant association between stethoscope contamination and frequency of cleaning it. Of the studied group only 26 subjects (17.3%) received education regarding stethoscope cleaning.

Conclusion:-There was evidence that bacteria can transfer from the skin of the patient to the stethoscope and from the stethoscope to the skin and there was poor education and assessing cleaning practices of stethoscopes.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Dec 13 2017
Journal Name
Al-khwarizmi Engineering Journal
Design and Simulation of L1-Adaptive Controller for Position Control of DC Servomotor
...Show More Authors

This paper presents L1-adaptive controller for controlling uncertain parameters and time-varying unknown parameters to control the position of a DC servomotor. For the purpose of comparison, the effectiveness of L1-adaptive controller for position control of studied servomotor has been examined and compared with another adaptive controller; Model Reference Adaptive Controller (MRAC). Robustness of both L1-adaptive controller and model reference adaptive controller to different input reference signals and different structures of uncertainty were studied. Three different types of input signals are taken into account; ramp, step and sinusoidal. The L1-adaptive controller ensured uniformly bounded

... Show More
View Publication Preview PDF
Publication Date
Wed Oct 18 2023
Journal Name
Iraqi National Journal Of Nursing Specialties
Assessment of Quality of Life for Patients with Permanent Pacemaker in Baghdad City
...Show More Authors

Objectives: To determine the (QoL) for patients with permanent pacemaker and to find-out the relationship between
these patients’ (QoL) and their sociodemographic characteristics such as age, gender, level of education, and
occupation.
Methodology: ٨ purposive non-probability” sample of (62) patient with permanent pacemaker was involved in this
study. The developed questionnaire consists of (4) parts which include !.demographic data form, 2.disease-related
information form, 3.socioeconomic data form, and 4.Permanent pacemaker patient’s quality of life questionnaire data
form. The validity and reliability of the questionnaire were determined through the application of a pilot study. ٨
descriptive statistical a

... Show More
View Publication Preview PDF
Publication Date
Thu Sep 01 2016
Journal Name
Journal Of Engineering | University Of Baghdad
Correction Factor for Methods of Installation of Piles Group in Sandy Iraqi Soils
...Show More Authors

Many problems are facing the installation of piles group in laboratory testing and the errors in results of load and settlement are measured experimentally may be happened due to select inadequate method of installation of piles group. There are three main methods of installation in-flight, pre-jacking and hammering methods. In order to find the correction factor between these methods the laboratory model tests were conducted on small-scale models. The parameters studied were the methods of installation (in-flight, pre-jacking and hammering method), the number of piles and in sandy soil in loose state. The results of experimental work show that the increase in the number of piles value led to increase in load carrying capacity of piled raft

... Show More
Publication Date
Sun Jun 05 2016
Journal Name
Baghdad Science Journal
Preparation and Characterization of Bimetallic Catalyst (NiO – CoO) for Desulfurization of Gas Oil
...Show More Authors

In this study NiO - CoO bimetallic catalysts are prepared with two Ni/Co ratios (70:30 and 80: 20) using the precipitation method of nitrate salts. The effects of Ni /Co ratio and preparation methods on the catalyst are analyzed by using different characterization techniques, i.e. atomic absorption (AA) , XRD, surface area and pore volume measurements according to the BET method . The results indicate that the best catalyst is the one containing the percentage of Ni :Co ( 70 : 30 ). Experiments indicate that the optimal conditions to prepare catalyst are stirring for three hours at a temperature of 60oC of the preparation , pH= (8-9) , calcination temperature at 400oC for two hours

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Feb 01 2019
Journal Name
Indian Journal Of Natural Sciences
Design and Test of Electrochemistry of Electrodes Catalysis for an Alkaline Fuel Cell
...Show More Authors

Preview PDF
Publication Date
Tue Nov 05 2013
Journal Name
Wit Transaction On Ecology And The Environments, Wit, Press No. 11
Remote sensing of water quality index for irrigation usability of the Euphrates River
...Show More Authors

irrigation use at many stations along the Euphrates River inside the Iraqi lands and to try to correlate the results with the satellite image analyses for the purpose of making a colored model for the Euphrates that can be used to predict the quality classifications of the river for irrigation use at any point along the river. The Bhargava method was used to calculate the water quality index for irrigation use at sixteen stations along the river from its entrance to the Iraqi land at Al-Qaim in Anbar governorate to its union with the Tigris River at Qurna in Basrah governorate. Coordinates of the sixteen stations of the Euphrates River were projected at the mosaic of Iraq satellite image which was taken from LANDSAT satellite for bands 1, 2

... Show More
View Publication Preview PDF
Publication Date
Wed Mar 29 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Validity of Generalized Standard Addition Method for a Mixture of Amino Acid Analysis
...Show More Authors

A Modified version of the Generlized standard addition method ( GSAM) was developed. This modified version was used for the quantitative determination of arginine   (Arg) and glycine ( Gly) in arginine  acetyl salicylate – glycine complex . According to this method two linear equations were solved to obtain the amounts of (Arg) and (Gly). The first equation was obtained by spectrophotometic measurement of the total absorbance of (Arg) and (Gly) colored complex with ninhydrin . The second equation was obtained by measuring the total acid consumed by total amino groups of (Arg) and ( Gly). The titration was carried out in non- aqueous media using perchloric acid in glacial acetic acid as a titrant. The developed metho

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Dec 31 2016
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Investigation of Binary Solvents Performance for Regeneration of Iraqi 15W- 40 Waste Lubricant
...Show More Authors

The aim of this study was to investigate the effectiveness of binary solvent for regeneration of spent lubricating oil by extraction-flocculation process. The regeneration was investigated by bench scale experiments by using locally provided solvents (Heavy Naphtha, n-Butanol, and iso-Butanol). Solvents to used oil, mixing time, mixing speed and temperatures were studied as operating parameters. The performance on three estimated depended key parameters, namely the percentage of base oil recovered (Yield), percent of oil loss (POL), and the percent of sludge removal (PSR) were used to evaluate the efficiency of the employed binary solvent on extraction process. The best solvent to solvent ratio for binary system were 30:70 for Heavy Naph

... Show More
View Publication Preview PDF
Publication Date
Mon Dec 11 2017
Journal Name
Al-khwarizmi Engineering Journal
Improvement of Mechanical and Rheological Properties of Natural Rubber for Anti-Vibration Applications
...Show More Authors

Abstract  

This research aims to study and improve the passivating specifications of rubber resistant to  vibration. In this paper, seven different rubber recipes were prepared based on mixtures of natural rubber(NR)  as an essential part in addition to the synthetic rubber (IIR, BRcis, SBR, CR)with different rates. Mechanical tests such as tensile strength, hardness, friction, resistance to compression, fatigue and creep testing in addition to the rheological test were performed. Furthermore, scanning electron microscopy (SEM)test was used to examine the structure morphology of rubber. After studying and analyzing the results, we found that, recipe containing (BRcis) of 40% from th

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Mar 05 2017
Journal Name
Baghdad Science Journal
An efficient of Sansevieriatrifasciataplantas biosorbent for the treatment of metal contaminated industrial effluents
...Show More Authors

Sansevieriatrifasciata was studied as a potential biosorbent for chromium, copper and nickel removal in batch process from electroplating and tannery effluents. Different parameters influencing the biosorption process such as pH, contact time, and amount of biosorbent were optimized while using the 80 mm sized particles of the biosorbent. As high as 91.3 % Ni and 92.7 % Cu were removed at pH of 6 and 4.5 respectively, while optimum Cr removal of 91.34 % from electroplating and 94.6 % from tannery effluents was found at pH 6.0 and 4.0 respectively. Pseudo second order model was found to best fit the kinetic data for all the metals as evidenced by their greater R2 values. FTIR characterization of biosorbent revealed the presence of carboxyl a

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (2)
Scopus Crossref