Preferred Language
Articles
/
jkmc-103
Administration of I.V. lidocaine before induction of general anesthesia prolong suxamethonium action in caesarian section surgeries. clinical assessment--------
...Show More Authors

Background: Known as suxamethonium or succinylcholine, is a medication used to cause short-term paralysis as part of general anesthesia. The duration of operation is one of the important factors accounting to the success of the operation. Simple safe available drug can change the plan of anesthesia.

Objective:  The purpose of this study was to assess adding Lidocaine three minutes intravenously before induction of general anesthesia on the duration of optimum prolongation the action of  Suxamethonium  . With other group with regular method.

Type of the study: a cross-sectional study 

 Methods: A 100 candidate to compare the effect of Lidocaine for unpremeditated patients ,American society of anesthesia( ASA)  physical status II .patients were scheduled for caesarian section surgery were randomly assigned to two groups: Group I patients received 1.5 mg/kg   Lidocaine 3 minutes before induction of general anesthesia, Group 2 patients received just the anesthetic agents.  For assessment of prolongation of action  the researcher Deepened on the clinical signs of recovery from Suxamethonium which are: spontaneous breathing, ability to swallow when we open the patient's lower jaw ( observing movement of the tongue ).between the two group Both groups received general anesthesia. 

Results:   The  of prolongation of Suxamethonium in elective cases in Group I was a about 7 - 15 minutes, while in Group II the time of Suxamethonium was about 3 - 5 minutes Conclusions :  The study concluded  that there was a significant difference  between the two groups from the side of suxamethonium time in group one( lidocaine group)as there was prolongation of time more than group two .

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Jun 28 2024
Journal Name
Curr Pharm Des
Synthesis, Characterization, and Antimicrobial Evaluation of Schiff base-mixed Ligand Complexes with Divalent Metal Ions Derived from Amoxicillin and Vanillin/Nicotinamide
...Show More Authors

Publication Date
Sun Nov 01 2015
Journal Name
Journal Of Dentistry
New functional and aesthetic composite materials used as an alternative to traditional post materials for the restoration of endodontically treated teeth
...Show More Authors

Objectives To tailor composites of polyethylene–hydroxyapatite to function as a new intracanal post for the restoration of endodontically treated teeth (ETT). Methods Silanated hydroxyapatite (HA) and zirconium dioxide (ZrO2) filled low-density polyethylene (LDPE) composites were fabricated by a melt extrusion process and characterised using infrared spectroscopy (FTIR), differential scanning calorimetry (DSC) and dynamic mechanical analysis (DMA). The flexural strength and modulus were determined in dry state and post ageing in simulated body fluid and fractured surfaces analysed by SEM. The water uptake and radiographic appearance of the experimental composites were also measured and compared with a commercially known endodontic fibre

... Show More
View Publication
Crossref (3)
Crossref
Publication Date
Thu Nov 30 2023
Journal Name
Iraqi Geological Journal
Multiple and Coherent Noise Removal from X-Profile 2D Seismic Data of Southern Iraq Using Normal Move Out-Frequency Wavenumber Technique
...Show More Authors

Multiple eliminations (de-multiple) are one of seismic processing steps to remove their effects and delineate the correct primary refractors. Using normal move out to flatten primaries is the way to eliminate multiples through transforming these data to frequency-wavenumber domain. The flatten primaries are aligned with zero axis of the frequency-wavenumber domain and any other reflection types (multiples and random noise) are distributed elsewhere. Dip-filter is applied to pass the aligned data and reject others will separate primaries from multiple after transforming the data back from frequency-wavenumber domain to time-distance domain. For that, a suggested name for this technique as normal move out- frequency-wavenumber domain

... Show More
View Publication
Scopus (3)
Scopus Crossref
Publication Date
Mon Nov 01 2021
Journal Name
Clinics And Research In Hepatology And Gastroenterology
Genetic polymorphism of fibroblast growth factor receptor 2 and trinucleotide repeat-containing 9 influence the susceptibility to HCV-induced hepatocellular carcinoma
...Show More Authors

Background Fibroblast growth factor receptor 2 (FGFR2) and trinucleotide repeat-containing 9 (TNRC9) gene polymorphisms have been associated with some cancers. We aimed to assess the association of FGFR2 rs2981582 and TNRC9 rs12443621 polymorphisms with hepatocellular cancer risk. Methods One hundred patients with HCV-induced HCC, 100 patients with chronic HCV infection, and 100 controls were genotyped for FGFR2 rs2981582 and TNRC9 rs12443621 using allele-specific Real-Time PCR analysis. Results FGFR2 rs2981582 genotype TT was associated with increased risk of HCC when compared to controls (OR = 3.09, 95% CI = 1.24–7.68). However, it was significantly associated with a lower risk of HCC when using HCV patients as controls (OR =

... Show More
Scopus (5)
Scopus
Publication Date
Fri Feb 28 2020
Journal Name
Neuroquantology
Using X-Ray Films for Evaluation efficiency of Unsaturated Polyester Reinforced by Lead Oxide as Shielding for Medical X-ray Devices
...Show More Authors

The largest use of x-ray in medical by dentists, employers or persons that needed by patients with specific conditions, lead to higher exposure of x-ray that may cause many diseases. In the present work radiography films have been used in evaluating the efficiency of using unsaturated polyester polymer reinforced with lead oxide (PbO) as shield material for medical x-ray devices, many parameters studied like concentration and thickness that they are increasing the attenuation of x-ray in them. The results show that the attenuation of X-ray increasing with concentration of reinforced material and with thickness, and the optical density decreases with increasing concentration from 0% to 50%, we chose 30% as suitable concentration to increase

... Show More
View Publication
Scopus Crossref
Publication Date
Mon Nov 08 2021
Journal Name
Physica Scripta
Adsorption of the eosin yellow dye by nickel oxide nanoparticles catalyzes via oxalate co-precipitation method: isotherm, kinetic and thermodynamic studies
...Show More Authors

View Publication
Scopus (11)
Crossref (12)
Scopus Clarivate Crossref
Publication Date
Mon Apr 30 2012
Journal Name
Asian Pacific Journal Of Cancer Prevention
Gelam and Nenas Honeys Inhibit Proliferation of HT 29 Colon Cancer Cells by Inducing DNA Damage and Apoptosis while Suppressing Inflammation
...Show More Authors

View Publication Preview PDF
Scopus (50)
Crossref (44)
Scopus Clarivate Crossref
Publication Date
Mon Dec 20 2021
Journal Name
Baghdad Science Journal
Dosimetric Verification of Gamma Passing Rate for Head and Neck Cases Treated with Intensity Modulated Radiation Therapy (IMRT) Treatment Planning Technique
...Show More Authors

Each Intensity Modulated Radiation Therapy (IMRT) plan needs to be tested and verified before any treatment to check its quality. Octavius 4D-1500 phantom detector is a modern and qualified device for quality assurance procedure. This study aims to compare the common dosimetric criteria 3%/3 mm with 2%/2 mm for H&N plans for the IMRT technique. Twenty-five patients with head and neck (H&N) tumor were with 6MV x-ray photon beam using Monaco 5.1 treatment planning software and exported to Elekta synergy linear accelerator then tested for pretreatment verification study using Octavius 4D-1500 phantom detector. The difference between planned and measured dose were assessed by using local and global gamma index (GI) analysis method at

... Show More
View Publication Preview PDF
Scopus (4)
Scopus Clarivate Crossref
Publication Date
Fri Dec 30 2022
Journal Name
Iraqi Journal Of Science
Structural, Optical, and Morphological Study of the Zinc Oxide Nano-Thin Films with Different Thickness Prepared by Pulsed Laser Deposition Technique
...Show More Authors

The goal of this investigation is to prepare zinc oxide (ZnO) nano-thin films by pulsed laser deposition (PLD) technique through Q-switching double frequency Nd:YAG laser (532 nm) wavelength, pulse frequency 6 Hz, and 300 mJ energy under vacuum conditions (10-3 torr) at room temperature. (ZnO) nano-thin films were deposited on glass substrates with different thickness of 300, 600 and 900 nm. ZnO films, were then annealed in air at a temperature of 500 °C for one hour. The results were compared with the researchers' previous theoretical study. The XRD analysis of ZnO nano-thin films indicated a hexagonal multi-crystalline wurtzite structure with preferential growth lines (100), (002), (101) for ZnO nano-thin films with different thi

... Show More
Scopus (4)
Crossref (1)
Scopus Crossref
Publication Date
Tue Jul 18 2023
Journal Name
Research On Chemical Intermediates
Effectual and rapid synthesis of bis(pyrazolyl)methanes and pyrazolopyranopyrimidines catalyzed by nano-[TSPSED][Cl]2 and investigating their biological activity
...Show More Authors

This investigation reports application of a mesoporous nanomaterial based on dicationic ionic liquid bonded to amorphous silica, namely nano-N,N,N′,N′-tetramethyl-N-(silican-propyl)-N′-sulfo-ethane-1,2-diaminium chloride (nano-[TSPSED][Cl]2), as an extremely effectual and recoverable catalyst for the generation of bis(pyrazolyl)methanes and pyrazolopyranopyrimidines in solvent-free conditions. In both synthetic protocols, the performance of this catalyst was very useful and general and presented attractive features including short reaction times with high yields, reasonable turnover frequency and turnover number values, easy workup, high performance under mild conditions, recoverability and reusability in 5 consecutive runs without lo

... Show More
View Publication
Scopus (2)
Crossref (2)
Scopus Clarivate Crossref