New simple and sensitive spectrophotometric methods for the determination of paracetamol in aqueous medium were developed. The first method is based on coupling of paracetamol with p-amino-2-hydroxy sodium benzoate (AHB) in the presence of sodium periodate, as oxidizing agent, to form a brownish-orange compound which shows a λmax at 470 nm. The molar absorptivity (εmax) of the colored product was found to be (3371) l.mole1.cm-1 and Sandel’s index 0.0449 μg.cm-2. The method follows Beer’s law in the concentration range of 12.5-500.0 μg of paracetamol in a final volume of 25 ml (0.5-20.0) μg.ml-1 with relative standard deviation percent (R.S.D%) ranged between 0.26-4.71% and accuracy, expressed by recovery percent, 95-106% for five levels of parcetamol concentration. The second method is based on indirect spectrophotometric procedure for the determination of paracetamol, after its hydrolysis in acidic medium and the reaction of hydrolyzed product (p-aminophenol) with p-amino-2-hydroxy sodium benzoate in the presence of sodium periodate in alkaline medium. A bluish-violet water soluble compound is formed with λmax =580nm and εmax =11884 l.mole-1.cm-1 and Sandel’s index 0.0127 μg.cm-2. Beer’s law is applicable for concentration range of paracetamol 12.5-500.0 μg per 25 ml volume of solution (0.5-20.0) μg.ml-1 with (R.S.D %) ranged between 0.60-1.10 % and recovery percent 94.28-101.6% for three levels of parcetamol concentration. The proposed methods were successfully applied for the determination of paracetamol in pharmaceutical preparations by both direct and standard addition method and for three levels of concentration.
A rapid, simple and sensitive spectrophotometric method for the determination of trace amounts of chromium (VI) was studied. The method is based on the reaction of chromium (VI) with promethazine forming a red colored species by chromium in hydrochloric acid medium and exhibits a maximum absorbance at 518 nm. A plot of absorbance with chromium (VI) gives a straight line indicating that Beer’s law has been obeyed over the range concentration of 0.05-4.0 µg/ml with a molar absorptivity of chromium(VI) 2.04  104 l.mol-1.cm-1 , Sandell’s sensitivity index of 0.0025 µg.cm-2 while the limit of detection (LOD) was found to be 0.0924 µg.ml
... Show MoreA rapid, simple and sensitive spectrophotometric method for the determination of trace amounts of chromium is studied. The method is based on the interaction of chromium with indigo carmine dye in acidic medium and the presence of oxalates as a catalyst for interaction, and after studying the absorption spectrum of the solution resulting observed decrease in the intensity of the absorption. As happened (Bleaching) for color dye, this palace and directly proportional to the chromium (VI) amount was measured intensity of the absorption versus solution was figurehead at a wavelength of 610 nm. A plot of absorbance with chromium (VI) concentration gives a straight line indicating that Beer’s law has been obeyed over the range of 0.5
... Show MoreBackground: Moyamoya disease (MMD) is a rare cerebrovascular disease characterized by bilateral stenosis starting at the supraclinoid internal carotid artery (ICA), with the development of a collateral network of vessels. It is an established cause of stroke in the pediatric age group. Despite its increasing prevalence in various parts of the world, it remains largely underrecognized in the Middle East, particularly in Iraq. This is the first case of MMD in an Iraqi patient undergoing surgery. Case description: A 12-year-old boy presents with a 3-months history of progressive behavioural changes. MRI revealed diffuse infarcts of different ages. MRA and CT angiography revealed extensive asymmetrical steno-occlusive changes of t
... Show MoreThe present study describes employing zero-, 1st - and 2nd -order derivative spectrophotometric methods have been developed for determination of lorazepam (LORA) and clonazepam (CLON) in commercially available tablets. LORA was determined by means of 1st (D1), 2nd (D2) derivative spectrophotometric techniques using zero cross, peak height, and Peak area. D1 used for the determination of CLON by using zero cross and peak height while D2 (zero cross) was used for the determination of CLON. The method was established to be linear in concentration containing different ratios of LORA and CLON range of (20-200 mg/L) and (5-35 mg/L) at wavelength range (250 -370 nm), (210-370nm) respectively. The proposed techniques are highly sensitive, precise a
... Show MoreThe research involved a rapid, automated and highly accurate developed CFIA/MZ technique for estimation of phenylephrine hydrochloride (PHE) in pure, dosage forms and biological sample. This method is based on oxidative coupling reaction of 2,4-dinitrophenylhydrazine (DNPH) with PHE in existence of sodium periodate as oxidizing agent in alkaline medium to form a red colored product at ʎmax )520 nm (. A flow rate of 4.3 mL.min-1 using distilled water as a carrier, the method of FIA proved to be as a sensitive and economic analytical tool for estimation of PHE.
Within the concentration range of 5-300 μg.mL-1, a calibration curve was rectilinear, where the detection limit was 3.252 μg.mL
Hydrogen productions were achieved by irradiating ethanol ic aqueous solutions (20%. v/v) containing mixtures of the ligand 2,4- dimethoxybcnzylidene-2-hydroxy aniline (HL) or one of i ts complexes (ML2) wi th the following divalent ions: fVbl (II), Fc(IT), Co(II). Ni( rt ), Cu(H) and Zn (11), as photosensi1izers, methyl viol ogen (MY.:-) as electron acceptor. ethylene diamine  
... Show MoreA simple, fast, selective of a new flow injection analysis method coupled with potentiometric detection was used to determine vitamin B1 in pharmaceutical formulations via the prepared new selective membranes. Two electrodes were constructed for the determination of vitamin B1 based on the ion-pair vitamin B1-phosphotungestic acid (B1-PTA) in a poly (vinyl chloride) supported with a plasticized di-butyl phthalate (DBPH) and di-butyl phosphate (DBP). Applications of these ion selective electrodes for the determination of vitamin B1 in the pharmaceutical preparations for batch and flow injection systems were described. The ion selective membrane exhibited a near-Nernstian slope values 56.88 and 58.53 mV / decade, with the linear dy
... Show More